EUVIMEDEUVIMED entdecken
Crossref

Influence of soft tissue thickness, blade type, and guide design on computer‐assisted esthetic crown lengthening

Panagiotis Ntovas iD, Lorenzo Tavelli, Basir A Barmak, Ronald E Jung, Maria-Elisa Galarraga-Vinueza iD

Journal of Periodontology · 2025

DOI: 10.1002/jper.24-0860 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Periodontology, 2025. Verfasst von Panagiotis Ntovas und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics, School of Dental Medicine, Tufts University, Boston, Massachusetts, USA. Hauptthemen laut MEDLINE: Crown Lengthening, Esthetics, Dental, Surgery, Computer-Assisted, Gingiva. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 42 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The aim of this study was to evaluate the effect of surgical guide design and type of blade, in relation to soft tissue thickness, on the accuracy of computer‐assisted crown lengthening.

Methods

A set of fully dentate anatomic maxilla models was implemented, using 2 types of soft‐tissue masks with a mean thickness of 1.5 and 3.5 mm, respectively, to simulate a clinical scenario of altered passive eruption. In total, 5 different gingivectomy techniques were assessed, implementing 3 different types of guidance and 2 different blades. The osteotomy was performed using 2 surgical guide designs. After each operation, the models were scanned and superimposed with the initial virtual design, to evaluate the accuracy of each evaluated approach through a set of linear measurements.

Results

For the gingivectomy as well as for the osteotomy, the mean discrepancy was increased in the presence of increased soft tissue thickness ( p < 0.05). The integration of supporting planes led to a decrease in the discrepancy compared to the conventional double guide design for both of the investigated soft‐tissue thicknesses ( p < 0.05). For the models with the normal soft tissue thickness, a lower mean discrepancy was presented, when a mini blade was used instead of a conventional surgical blade, irrespective of the guide design ( p < 0.05).

Conclusion

Computer‐assisted crown lengthening can be considered a feasible treatment option. Soft tissue thickness has to be taken into consideration during the design of the surgical template, in order additional support to be provided when it is needed. Surgical templates with integrated supporting planes can increase the accuracy of computer‐assisted crown lengthening. Plain language summary Gingival architecture plays a crucial role in achieving smile harmony. For patients seeking an esthetic smile, periodontal plastic surgery can be a valuable option, as it can improve the harmony between the teeth and the gingiva. Excessive gingiva display can be managed using various treatment approaches, depending on the etiology. When periodontal surgery is a part of the treatment plan, the procedure can be digitally planned using a 3D diagnostic design and seamlessly transferred to the surgical field through a 3D printed surgical template. The present research aimed to evaluate the influence of surgical guide design, gingival thickness, and surgical blade type on the accuracy of the periodontal surgery. Two different designs of surgical templates, providing a different degree of guidance, as well as 2 types of surgical blades were used to simulate the surgical procedure. To evaluate the aforementioned parameters, models with 2 different gingival mask thickness were used. Based to the results of the present study, gingival thickness, surgical template design, and blade type can significantly affect the accuracy of the surgery procedure.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Crown LengtheningEsthetics, DentalSurgery, Computer-AssistedGingivaHumansMaxillaGingivectomyOsteotomyModels, AnatomicModels, DentalComputer-Aided Design

Stichwörter der Autor:innen

crown lengtheningdigital workflowguided surgerysmile estheticssoft tissue

Autor:innen und Institutionen

  • Department of Prosthodontics, School of Dental Medicine, Tufts University, Boston, Massachusetts, USA.
  • Department of Oral Medicine, Infection, and Immunity, Division of Periodontology, Harvard School of Dental Medicine, Boston, Massachusetts, USA.
  • School of Dentistry, Universidad Catolica de Santiago de Guayaquil (UCSG), Guayaquil, Ecuador.
  • Department of Clinical Research and Biostatistics, Eastman Institute for Oral Health, University of Rochester Medical Center, Rochester, New York, USA.
  • Center of Dental Medicine, Clinic of Reconstructive Dentistry, University of Zürich, Zürich, Switzerland.
  • School of Dentistry, Universidad de las Américas (UDLA), Quito, Ecuador.

ORCID-Profile: Panagiotis Ntovas, Maria-Elisa Galarraga-Vinueza

Zitieren

APA

Ntovas, P., Tavelli, L., Barmak, B. A., Jung, R. E., & Galarraga-Vinueza, M. E. (2025). Influence of soft tissue thickness, blade type, and guide design on computer‐assisted esthetic crown lengthening. Journal of Periodontology. https://doi.org/10.1002/jper.24-0860

Vancouver

Ntovas P, Tavelli L, Barmak BA, Jung RE, Galarraga-Vinueza ME. Influence of soft tissue thickness, blade type, and guide design on computer‐assisted esthetic crown lengthening. Journal of Periodontology. 2025. doi:10.1002/jper.24-0860

BibTeX
@article{Ntovas2025,
  author = {Ntovas, Panagiotis and Tavelli, Lorenzo and Barmak, Basir A and Jung, Ronald E and Galarraga-Vinueza, Maria-Elisa},
  title = {Influence of soft tissue thickness, blade type, and guide design on computer‐assisted esthetic crown lengthening},
  journal = {Journal of Periodontology},
  year = {2025},
  doi = {10.1002/jper.24-0860}
}
Kostenlos starten →