EUVIMEDEUVIMED entdecken
Crossref

Optimizing Volar Lunate Facet Fracture Fixation: Finite Element Analysis and Cadaveric Testing

Alireza Gholipour iD, Jonathan Lans iD, Alyssa Lee, Marco T Di Stefano iD, Augustus D Mazzocca, Abhiram R Bhashyam

Journal of Orthopaedic Research · 2026-11 · 44 (11)

DOI: 10.1002/jor.70305 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Orthopaedic Research, online erschienen am 28.10.2026. Verfasst von Alireza Gholipour und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Enable Education and Research Facility, Massachusetts General Brigham Hospital, Harvard Medical School, Boston, Ma…. Hauptthemen laut MEDLINE: Fracture Fixation, Internal, Lunate Bone, Wrist Fractures. Die Arbeit nennt 30 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Volar lunate facet (VLF) fractures are prone to loss of reduction after volar plating. We used finite element analysis (FEA) and cadaveric testing to identify failure mechanisms and determine how screw configuration alters load transfer. A CT‐derived radius model with a 10 × 15 × 5‐mm VLF fragment was fixed with a 4‐hole hook plate using locking and nonlocking (NL) screws. A 500‐N radiolunate compressive load was applied, and von Mises stresses were quantified. Sensitivity analyses varied loading, bone density, fracture characteristics, and implant material. Ten distal radii underwent cyclic loading followed by load‐to‐failure testing; failure modes and locations were compared with FEA hotspots. FEA identified two stress concentrations: the distal plate contour/screw‐hole region and the ulnar hook insertion into the VLF fragment. In the baseline 1[NL]&3[NL] construct, peak construct and radius stresses were 697.2 and 154.6 MPa. The 1[NL]&2[NL] configuration produced the lowest stresses (54.5 and 27.3 MPa), whereas locking hole 3 reduced construct stress to 587.2 MPa. Cadaver failure load was 1239.2 ± 438.5 N (range: 630.0–1990.1 N); failures were loss of reduction/fracture dislocation (4/10) or plate failure (6/10), with failure locations corresponding to FEA hotspots. Off‐axis loading, reduced bone density, and fracture‐line translation increased construct stress and altered hotspot location. FEA‐predicted hook–fragment stress corresponded to loss of reduction, whereas distal plate stress corresponded to plate failure. Among modeled configurations, 1[NL]&2[NL] minimized construct and radius stress, although unbalanced cadaveric groups preclude claims of clinical superiority. These findings support fragment capture while minimizing distal plate stress.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Fracture Fixation, InternalLunate BoneWrist FracturesHumansFinite Element AnalysisCadaverBone PlatesBone ScrewsStress, MechanicalBiomechanical Phenomena

Stichwörter der Autor:innen

cadaver biomechanical testingfinite element analysisfixation failurevolar hook platevolar lunate facet

Autor:innen und Institutionen

  • Department of Orthopaedic Surgery, Enable Education and Research Facility, Massachusetts General Brigham Hospital, Harvard Medical School, Boston, Massachusetts, USA.
  • Department of Orthopaedic Surgery, Emory University School of Medicine, Atlanta, Georgia.

ORCID-Profile: Alireza Gholipour, Jonathan Lans, Marco T Di Stefano

Zitieren

APA

Gholipour, A., Lans, J., Lee, A., Di Stefano, M. T., Mazzocca, A. D., & Bhashyam, A. R. (2026). Optimizing Volar Lunate Facet Fracture Fixation: Finite Element Analysis and Cadaveric Testing. Journal of Orthopaedic Research, 44(11). https://doi.org/10.1002/jor.70305

Vancouver

Gholipour A, Lans J, Lee A, Di Stefano MT, Mazzocca AD, Bhashyam AR. Optimizing Volar Lunate Facet Fracture Fixation: Finite Element Analysis and Cadaveric Testing. Journal of Orthopaedic Research. 2026;44(11). doi:10.1002/jor.70305

BibTeX
@article{Gholipour2026,
  author = {Gholipour, Alireza and Lans, Jonathan and Lee, Alyssa and Di Stefano, Marco T and Mazzocca, Augustus D and Bhashyam, Abhiram R},
  title = {Optimizing Volar Lunate Facet Fracture Fixation: Finite Element Analysis and Cadaveric Testing},
  journal = {Journal of Orthopaedic Research},
  year = {2026},
  volume = {44},
  number = {11},
  doi = {10.1002/jor.70305}
}
Kostenlos starten →