Measuring Interference, Internal Bone Displacements and Strains Following Cementless Tibial Tray Implantation Using Micro‐CT and DVC
Journal of Orthopaedic Research · 2026-11 · 44 (11)
DOI: 10.1002/jor.70304 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Orthopaedic Research, online erschienen am 17.11.2026. Verfasst von Kieran J. Bennett und 8 weiteren Autor:innen. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Australian Research Council.
Abstract (Originalsprache)
The primary stability of proximal tibia cementless total knee arthroplasty components is achieved through a bone‐implant interference fit. This study aimed to develop the methods to explore this interference fit, and to quantify the resultant internal bone displacement and strain distributions due to implantation with cementless tibial components into human cadaveric proximal tibiae for different implant designs, featuring wings, keel and two types of pegs. Three in‐development titanium implants were implanted into three human cadaveric tibiae. Micro‐CT images were taken both after resection and after implantation, and image volumes were rigidly registered in the tibial metaphysis. Interference fit was quantified as the distance between the implant boundary in the implanted images and the bone in the resected images. Digital volume correlation was then used to calculate the internal bone displacements and strains. More than 75% of the surface of the implant wing geometries had bone‐implant interference (> 0 μm). The total bone displacement due to implantation ranged from 198 to 259 μm and was dominated by bone displacements in the posterior and inferior directions. The 95th percentile minimum principal strain within 5.5 mm of the implant surface ranged from −12,353 to −20,882 μϵ, with 12% to 20% of this volume demonstrating strains which indicate yielding. By comparing the results from titanium knee implants with three different designs, we developed a method which can be used for identifying the effect of different implant designs on internal bone mechanics in experimental studies on cadaveric bone following implantation.
Förderung
- Australian Research Council
Zitieren
APA
Bennett, K. J., Wearne, L. S., Rapagna, S., Reddy, S. P., Dohm, J. C., Schilling, C., Richter, B., Grupp, T. M., & Perilli, E. (2026). Measuring Interference, Internal Bone Displacements and Strains Following Cementless Tibial Tray Implantation Using Micro‐CT and DVC. Journal of Orthopaedic Research, 44(11). https://doi.org/10.1002/jor.70304
Vancouver
Bennett KJ, Wearne LS, Rapagna S, Reddy SP, Dohm JC, Schilling C, et al. Measuring Interference, Internal Bone Displacements and Strains Following Cementless Tibial Tray Implantation Using Micro‐CT and DVC. Journal of Orthopaedic Research. 2026;44(11). doi:10.1002/jor.70304
BibTeX
@article{Bennett2026,
author = {Bennett, Kieran J. and Wearne, Lauren S. and Rapagna, Sophie and Reddy, Sunil P. and Dohm, Julius C. and Schilling, Christoph and Richter, Berna and Grupp, Thomas M. and Perilli, Egon},
title = {Measuring Interference, Internal Bone Displacements and Strains Following Cementless Tibial Tray Implantation Using Micro‐CT and DVC},
journal = {Journal of Orthopaedic Research},
year = {2026},
volume = {44},
number = {11},
doi = {10.1002/jor.70304}
}
EUVIMED