Application of Focused Ultrasound for the Treatment of Tendinopathy: An In Vivo Feasibility, Safety, and Efficacy Study
Journal of Orthopaedic Research · 2026
DOI: 10.1002/jor.70257 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Orthopaedic Research, 2026. Verfasst von Chitra Meduri und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, Virginia Tech, Blacksburg, Virginia, USA. Hauptthemen laut MEDLINE: Tendinopathy, Ultrasonic Therapy, Achilles Tendon. Die Arbeit nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Edward Via College of Osteopathic Medicine, Institute for Critical Technology and Applied Science, Institute for Critical Technologies and Applied Science, Virginia Tech.
Abstract (Originalsprache)
Mechanical loading‐based rehabilitation of tendinopathies improves symptoms and tendon biomechanics, motivating interest in non‐invasive treatment options. Focused ultrasound (FUS) is a promising technology that precisely targets tissue regions, inducing desired bioeffects while minimally affecting surrounding tissues. To explore its potential for treating tendinopathies, we sequentially characterized FUS‐induced tendon temperature elevations ex vivo, treated uninjured mouse Achilles tendons in vivo, and finally assessed the in vivo effects of FUS treatment of tendinopathic tissues. FUS (1.1 MHz transducer) consisted of thermal‐dominant (0.5 MPa peak‐peak pressure, continuous pulsing, 100% duty cycle) or mechanical‐dominant (2 or 5 MPa, 10 Hz, 1% duty cycle) pulsing for four sessions over 1 week. No adverse events were observed, and mice did not exhibit pain or distress. Relative to untreated tendons, thermal FUS treatment of uninjured tendons did not alter mechanical properties while mechanical (5 MPa) FUS treatment significantly reduced maximum stress and elastic modulus. Tendons from both treatments exhibited mild matrix disorganization and increased cellularity, indicating an adaptive response. When applied to injured tendons, mechanical (5 MPa) FUS treatment reduced cross‐sectional area and restored elastic modulus and yield stress to levels of naïve tendons. Although signs of injury persisted, the FUS‐treated region exhibited fewer rounded cells and a reduction in sulfated glycosaminoglycan deposits, indicative of injury improvement. These pre‐clinical studies demonstrate the safety, feasibility and preliminary efficacy of FUS for tendinopathy treatment. This foundational methodology facilitates further exploration of acoustic treatment parameters and strategies to augment tendon healing.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Biomedical Engineering, Virginia Tech, Blacksburg, Virginia, USA.
- Translational Biology, Medicine, and Health Graduate Program, Virginia Tech, Blacksburg, Virginia, USA.
- Edward Via College of Osteopathic Medicine, Blacksburg, Virginia, USA.
ORCID-Profile: Vincent M Wang
Förderung
- Edward Via College of Osteopathic Medicine
- Institute for Critical Technology and Applied Science
- Institute for Critical Technologies and Applied Science, Virginia Tech
Zitieren
APA
Meduri, C., Rogers, E. P., Easley, D. C., Gunnar Brolinson, P., Vlaisavljevich, E., & Wang, V. M. (2026). Application of Focused Ultrasound for the Treatment of Tendinopathy: An In Vivo Feasibility, Safety, and Efficacy Study. Journal of Orthopaedic Research. https://doi.org/10.1002/jor.70257
Vancouver
Meduri C, Rogers EP, Easley DC, Gunnar Brolinson P, Vlaisavljevich E, Wang VM. Application of Focused Ultrasound for the Treatment of Tendinopathy: An In Vivo Feasibility, Safety, and Efficacy Study. Journal of Orthopaedic Research. 2026. doi:10.1002/jor.70257
BibTeX
@article{Meduri2026,
author = {Meduri, Chitra and Rogers, Emily P and Easley, Dylan C and Gunnar Brolinson, P and Vlaisavljevich, Eli and Wang, Vincent M},
title = {Application of Focused Ultrasound for the Treatment of Tendinopathy: An In Vivo Feasibility, Safety, and Efficacy Study},
journal = {Journal of Orthopaedic Research},
year = {2026},
doi = {10.1002/jor.70257}
}