EUVIMEDEUVIMED entdecken
Crossref

Quantifying Multiplanar Alignment Errors From Patient‐Specific Guide Malpositioning in Medial Opening Wedge High Tibial Osteotomy

Christopher J Davey, Takaaki Hiranaka iD, David Parker

Journal of Orthopaedic Research · 2026-04 · 44 (4)

DOI: 10.1002/jor.70199 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Orthopaedic Research, online erschienen am 01.04.2026. Verfasst von Christopher J Davey und 2 weiteren Autor:innen. Beteiligte Einrichtung: Sydney Orthopaedic Research Institute, Sydney, New South Wales, Australia. Hauptthemen laut MEDLINE: Osteotomy, Tibia. Die Arbeit nennt 24 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Patient‐specific cutting guides are widely used in medial opening wedge high tibial osteotomy to improve alignment accuracy, yet their multiplanar sensitivity to intraoperative malpositioning remains poorly quantified. This study investigated how translational and rotational malpositioning of patient‐specific cutting guides affect postoperative multiplanar alignment using virtual surgical simulation. Virtual osteotomy procedures were performed on twenty tibial models reconstructed from preoperative computed tomography scans, targeting a 62.5% weight‐bearing line. Guides were systematically malpositioned vertically, rotationally, and horizontally along the anteromedial tibial cortex. Postoperative medial proximal tibial angle, posterior proximal tibial angle, and tibial torsion were compared with the ideal plan, and clinically acceptable alignment error was defined as within 1°. Vertical malpositioning predominantly affected coronal alignment, with distal displacement greater than 8 mm producing medial proximal tibial angle overcorrection beyond acceptable limits, while posterior proximal tibial angle and tibial torsion were relatively insensitive within 10 mm. Rotational malpositioning affected all alignment parameters, with tibial torsion being the most sensitive, and acceptable alignment was maintained only between −10° and +8°. Horizontal malpositioning produced variable effects, particularly on posterior proximal tibial angle, with acceptable alignment maintained between −4 mm and +3 mm, while tibial torsion was minimally affected. Clinical Significance: This study defines clinically acceptable ranges of patient‐specific cutting guide malpositioning in medial opening wedge high tibial osteotomy and identifies which displacement modes most strongly affect coronal, sagittal, and axial alignment. These findings provide practical thresholds to guide PSI design, fixation, and intraoperative placement, helping to reduce alignment errors arising from subtle guide mispositioning.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

OsteotomyTibiaHumansTomography, X-Ray ComputedFemaleMaleMiddle Aged

Stichwörter der Autor:innen

high tibial osteotomymedial opening wedgepatient‐specific instrumentationsurgical guide malpositioningvirtual surgical simulation

Autor:innen und Institutionen

  • Sydney Orthopaedic Research Institute, Sydney, New South Wales, Australia.
  • Department of Orthopaedic Surgery, Okayama University Graduate School of Medicine, Dentistry, and Pharmaceutical Sciences, Okayama, Japan.

ORCID-Profile: Takaaki Hiranaka

Zitieren

APA

Davey, C. J., Hiranaka, T., & Parker, D. (2026). Quantifying Multiplanar Alignment Errors From Patient‐Specific Guide Malpositioning in Medial Opening Wedge High Tibial Osteotomy. Journal of Orthopaedic Research, 44(4). https://doi.org/10.1002/jor.70199

Vancouver

Davey CJ, Hiranaka T, Parker D. Quantifying Multiplanar Alignment Errors From Patient‐Specific Guide Malpositioning in Medial Opening Wedge High Tibial Osteotomy. Journal of Orthopaedic Research. 2026;44(4). doi:10.1002/jor.70199

BibTeX
@article{Davey2026,
  author = {Davey, Christopher J and Hiranaka, Takaaki and Parker, David},
  title = {Quantifying Multiplanar Alignment Errors From Patient‐Specific Guide Malpositioning in Medial Opening Wedge High Tibial Osteotomy},
  journal = {Journal of Orthopaedic Research},
  year = {2026},
  volume = {44},
  number = {4},
  doi = {10.1002/jor.70199}
}
Kostenlos starten →