Precision, Accuracy, and Observer Reliability of Computed Tomography‐Based Radiostereometric Analysis in Measuring Femoral Stem Migration In Vitro

Vasileios Angelomenos iD, Maziar Mohaddes, Bita Shareghi, Henrik Malchau, Johan Nils Kärrholm, Raed Itayem

Journal of Orthopaedic Research · 2026

DOI: 10.1002/jor.70146 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Orthopaedic Research, 2026. Verfasst von Vasileios Angelomenos und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden. Hauptthemen laut MEDLINE: Radiostereometric Analysis, Tomography, X-Ray Computed, Hip Prosthesis, Arthroplasty, Replacement, Hip. Die Arbeit nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Guldbyxans Stiftelse; Sahlgrenska University Hospitals Research Foundations.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

CT‐based radiostereometric analysis (CT‐RSA) is a method of measuring implant micromotion using low‐dose CT scans. We evaluated the precision, accuracy, and observer reliability of CT‐RSA for measuring femoral stem translation in THA in vitro. A cementless femoral stem was implanted in a synthetic femur mounted on a calibrated micrometer platform. Controlled translations were applied along each orthogonal axis across 5 series, generating 90 CT data sets. Only translational micromotions were imposed and analyzed. Precision was calculated from double examinations—repeated scans of the same displacement acquired in a different series—yielding 60 pairs. The femoral stem, head, and bone were segmented, the head's geometric center was defined, and translations were analyzed. Because the platform was fixed 90° to the femoral neck (CCD 135°), data were reported both on native axes, and after a 45° counterclockwise rotation to the conventional RSA frame. Precision was estimated from double examinations (SD × t ), accuracy from RMSE versus micrometer readings (RMSE × t ), and reliability from intraclass correlation coefficients (ICC) by two blinded observers. On native axes, precision ranged 0.06–0.08 mm and accuracy 0.09–0.13 mm. On transformed axes, precision ranged 0.06–0.07 mm and accuracy 0.03–0.14 mm. Intraobserver reliability was excellent (mean ICC 0.99 for all axes), as well as interobserver reliability (mean ICC 0.91–0.98). CT‐RSA achieved sub‐tenth‐millimeter precision with high repeatability and excellent observer agreement. These findings support CT‐RSA as a viable alternative for early migration measurement in THA research. Clinical validation with low‐dose protocols and predefined quality criteria remains warranted.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiostereometric AnalysisTomography, X-Ray ComputedHip ProsthesisArthroplasty, Replacement, HipFemurReproducibility of ResultsObserver VariationHumans

Stichwörter der Autor:innen

CTCT‐RSAaccuracycomputed tomographymigrationprecisionradiostereometric analysisreliabilitytotal hip arthroplasty

Autor:innen und Institutionen

  • Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
  • Department of Hand Surgery, Sahlgrenska University Hospital, Gothenburg, Sweden.
  • Department of Orthopaedics, Skåne University Hospital, Hässleholm, Sweden.
  • Unit for Orthopaedics, Department of Clinical Sciences, Lund University, Lund, Sweden.
  • Department of Orthopaedics, Sahlgrenska University Hospital, Gothenburg, Sweden.

ORCID-Profile: Vasileios Angelomenos

Förderung

  • Guldbyxans Stiftelse; Sahlgrenska University Hospitals Research Foundations

Zitieren

APA

Angelomenos, V., Mohaddes, M., Shareghi, B., Malchau, H., Kärrholm, J. N., & Itayem, R. (2026). Precision, Accuracy, and Observer Reliability of Computed Tomography‐Based Radiostereometric Analysis in Measuring Femoral Stem Migration In Vitro. Journal of Orthopaedic Research. https://doi.org/10.1002/jor.70146

Vancouver

Angelomenos V, Mohaddes M, Shareghi B, Malchau H, Kärrholm JN, Itayem R. Precision, Accuracy, and Observer Reliability of Computed Tomography‐Based Radiostereometric Analysis in Measuring Femoral Stem Migration In Vitro. Journal of Orthopaedic Research. 2026. doi:10.1002/jor.70146

BibTeX
@article{Angelomenos2026,
  author = {Angelomenos, Vasileios and Mohaddes, Maziar and Shareghi, Bita and Malchau, Henrik and Kärrholm, Johan Nils and Itayem, Raed},
  title = {Precision, Accuracy, and Observer Reliability of Computed Tomography‐Based Radiostereometric Analysis in Measuring Femoral Stem Migration In Vitro},
  journal = {Journal of Orthopaedic Research},
  year = {2026},
  doi = {10.1002/jor.70146}
}
Kostenlos starten →