EUVIMEDEUVIMED entdecken
ValidierungsstudieOpen Access · CC BY-NC-ND 4.0

Sonographic Patellar and Quadriceps Tendon Length Pre‐ and Post‐Autograft Harvest: Reliability and Concurrent Validity

Andrew Sprague iD, George Raum iD, Naoaki Ito iD

Journal of Orthopaedic Research · 2026

DOI: 10.1002/jor.70004 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift Journal of Orthopaedic Research, 2026. Verfasst von Andrew Sprague und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physical Therapy, University of Pittsburgh, Pittsburgh, Pennsylvania, USA. Hauptthemen laut MEDLINE: Patellar Ligament, Quadriceps Muscle, Tendons. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NIAMS NIH HHS, This study was supported by the National Institutes of Health, National Institute of Arthritis and Musculoskeletal Diseases under award numbers #U01AR076144 an….

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Extensor mechanism autografts used for anterior cruciate ligament reconstruction, namely bone‐patellar tendon‐bone (BPTB) and quadriceps tendon (QT), may result in harvest‐site tendon elongation. Extended field of view (EFOV) ultrasound imaging has the potential to evaluate changes in tendon length, but the reliability and validity of these methods in this population are unknown. This study evaluated the reliability and concurrent validity of measurement methods to assess sonographic quadriceps and patellar tendon lengths before and after autograft harvest. Reliability: EFOV ultrasound images were collected by one examiner pre‐ and post‐graft harvest and measured by three examiners in 20 participants (10 BPTB, 10 QT). Measurements were repeated by one examiner blinded to the initial results. Examiners utilized two measurement methods: (1) traditional bony landmarks; (2) novel landmarks less likely to be compromised by bone plug harvest. Validity: EFOV measurements were compared to direct caliper measurements in 20 cadavers. Reliability and validity were examined using intraclass correlation coefficients (ICCs), Pearson's correlation coefficients, and measures of error. Intra‐rater reliability for both methods were good to excellent (Pre: Patellar: 0.81–0.99, Quadriceps: 0.97; Post: Patellar 0.82–0.91, Quadriceps: 0.91–0.92) and moderate to excellent for inter‐rater (ICCs Pre: Patellar: 0.90–0.99, Quadriceps: 0.96; Post: Patellar: 0.80–0.96, Quadriceps: 0.71–0.75). Standard errors of the measurement were lower for the traditional method for each tendon. ICCs for concurrent validity were moderate to good (Patellar: 0.73, Quadriceps: 0.83). Statement of Clinical Significance EFOV ultrasound can reliably measure patellar and quadriceps tendon length before and after autograft harvest for ACLR.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Patellar LigamentQuadriceps MuscleTendonsHumansMaleUltrasonographyFemaleReproducibility of ResultsMiddle AgedAutograftsAgedAdultAnterior Cruciate Ligament ReconstructionTissue and Organ HarvestingCadaver

Stichwörter der Autor:innen

ACLcadaverextended‐field‐of‐viewextensor mechanismultrasound

Autor:innen und Institutionen

  • Department of Physical Therapy, University of Pittsburgh, Pittsburgh, Pennsylvania, USA.
  • Department of Physical Medicine and Rehabilitation, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania, USA.
  • Department of Orthopedics and Rehabilitation, University of Wisconsin - Madison, Madison, Wisconsin, USA.
  • Badger Athletic Performance Program, University of Wisconsin - Madison, Madison, Wisconsin, USA.

ORCID-Profile: Andrew Sprague, George Raum, Naoaki Ito

Förderung

  • NIAMS NIH HHS
  • This study was supported by the National Institutes of Health, National Institute of Arthritis and Musculoskeletal Diseases under award numbers #U01AR076144 an…

Zitieren

APA

Sprague, A., Raum, G., & Ito, N. (2026). Sonographic Patellar and Quadriceps Tendon Length Pre‐ and Post‐Autograft Harvest: Reliability and Concurrent Validity. Journal of Orthopaedic Research. https://doi.org/10.1002/jor.70004

Vancouver

Sprague A, Raum G, Ito N. Sonographic Patellar and Quadriceps Tendon Length Pre‐ and Post‐Autograft Harvest: Reliability and Concurrent Validity. Journal of Orthopaedic Research. 2026. doi:10.1002/jor.70004

BibTeX
@article{Sprague2026,
  author = {Sprague, Andrew and Raum, George and Ito, Naoaki},
  title = {Sonographic Patellar and Quadriceps Tendon Length Pre‐ and Post‐Autograft Harvest: Reliability and Concurrent Validity},
  journal = {Journal of Orthopaedic Research},
  year = {2026},
  doi = {10.1002/jor.70004}
}
Kostenlos starten →