EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

In Vivo Kinematics for Various Robotically Performed Total Knee Arthroplasty Implant Designs

Michael Tim-Yun Ong iD, Michael T LaCour iD, Patrick Shu-Hang Yung, Garett M Dessinger, Richard D Komistek

Journal of Orthopaedic Research · 2025

DOI: 10.1002/jor.26091 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Orthopaedic Research, 2025. Verfasst von Michael Tim-Yun Ong und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics and Traumatology, Faculty of Medicine, The Chinese University of Hong Kong, Hong Kong. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Knee Prosthesis, Robotic Surgical Procedures, Knee Joint. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: This study was supported by Smith & Nephew Orthopaedics..

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Although it is well‐documented that robotic‐assisted total knee arthroplasty (TKA) can improve surgical precision, evaluations of the postoperative kinematics of patients implanted using robotics remain less common. The objective of this study is to analyze the weight‐bearing kinematics for multiple TKAs implanted using two different surgical robots. In vivo knee kinematics were assessed using fluoroscopy for 28 subjects implanted with a Bi‐Cruciate Stabilized (BCS) TKA, 23 with a Bi‐Cruciate Retaining (BCR) TKA, 13 with a posterior stabilized (PS) TKA, and 22 with a cruciate retaining (CR) TKA. All subjects were implanted by the same surgeon using the respective company's surgical robot. All subjects performed a weight‐bearing deep knee bend. Parameters of interest include the femoral condylar anterior/posterior motion, femorotibial axial rotation, and weight‐bearing range‐of‐motion. The BCS TKA experienced the most posterior rollback, 13.4 ± 4.4 mm for the lateral condyle and 5.8 ± 2.5 mm for the medial condyle. These subjects also experienced the most femorotibial axial rotation, +9.3 ± 5.3°. Conversely, CR subjects experienced the least overall rollback and most anterior sliding, 0.4 ± 3.8 mm of lateral rollback and 1.9 ± 4.1 mm of medial anterior sliding. Implant design appears to play a significant role in postoperative kinematics. Improved stability is evident in TKAs that account for the ACL. However, no system behaved significantly better nor worse than previously published literature evaluating standard instrumentation. Level of Evidence: Level 3, retrospective cohort study.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneeKnee ProsthesisRobotic Surgical ProceduresKnee JointHumansBiomechanical PhenomenaAgedMaleFemaleMiddle AgedRange of Motion, ArticularProsthesis DesignWeight-BearingAged, 80 and over

Stichwörter der Autor:innen

kinematicskneeprimaryrobotics

Autor:innen und Institutionen

  • Department of Orthopaedics and Traumatology, Faculty of Medicine, The Chinese University of Hong Kong, Hong Kong.
  • Mechanical, Aerospace, and Biomedical Engineering, Center for Musculoskeletal Research, University of Tennessee-Knoxville, Knoxville, Tennessee, USA.

ORCID-Profile: Michael Tim-Yun Ong, Michael T LaCour

Förderung

  • This study was supported by Smith & Nephew Orthopaedics.

Zitieren

APA

Ong, M. T., LaCour, M. T., Yung, P. S., Dessinger, G. M., & Komistek, R. D. (2025). In Vivo Kinematics for Various Robotically Performed Total Knee Arthroplasty Implant Designs. Journal of Orthopaedic Research. https://doi.org/10.1002/jor.26091

Vancouver

Ong MT, LaCour MT, Yung PS, Dessinger GM, Komistek RD. In Vivo Kinematics for Various Robotically Performed Total Knee Arthroplasty Implant Designs. Journal of Orthopaedic Research. 2025. doi:10.1002/jor.26091

BibTeX
@article{Ong2025,
  author = {Ong, Michael Tim-Yun and LaCour, Michael T and Yung, Patrick Shu-Hang and Dessinger, Garett M and Komistek, Richard D},
  title = {In Vivo Kinematics for Various Robotically Performed Total Knee Arthroplasty Implant Designs},
  journal = {Journal of Orthopaedic Research},
  year = {2025},
  doi = {10.1002/jor.26091}
}
Kostenlos starten →