Assessing paraspinal muscle atrophy with electrical impedance myography: Limitations and insights
Journal of Orthopaedic Research · 2024
DOI: 10.1002/jor.25848 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Orthopaedic Research, 2024. Verfasst von Ali E Guven und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Hospital for Special Surgery, Weill Cornell Medicine, New York, USA. Hauptthemen laut MEDLINE: Paraspinal Muscles, Electric Impedance, Muscular Atrophy, Magnetic Resonance Imaging. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 31 Literaturangaben.
Abstract (Originalsprache)
Paraspinal muscle atrophy is gaining attention in spine surgery due to its link to back pain, spinal degeneration and worse postoperative outcomes. Electrical impedance myography (EIM) is a noninvasive diagnostic tool for muscle quality assessment, primarily utilized for patients with neuromuscular diseases. However, EIM's accuracy for paraspinal muscle assessment remains understudied. In this study, we investigated the correlation between EIM readings and MRI‐derived muscle parameters, as well as the influence of dermal and subcutaneous parameters on these readings. We retrospectively analyzed patients with lumbar spinal degeneration who underwent paraspinal EIM assessment between May 2023 to July 2023. Paraspinal muscle fatty infiltration (FI) and functional cross‐sectional area (fCSA), as well as the subcutaneous thickness were assessed on MRI scans. Skin ultrasound imaging was assessed for dermal thickness and the echogenicities of the dermal and subcutaneous layers. All measurements were performed on the bilaterally. The correlation between EIM readings were compared with ultrasound and MRI parameters using Spearman's correlation analyses. A total of 20 patients (65.0% female) with a median age of 69.5 years (IQR, 61.3–73.8) were analyzed. The fCSA and FI did not significantly correlate with the EIM readings, regardless of frequency. All EIM readings across frequencies correlated with subcutaneous thickness, echogenicity, or dermal thickness. With the current methodology, paraspinal EIM is not a valid alternative to MRI assessment of muscle quality, as it is strongly influenced by the dermal and subcutaneous layers. Further studies are required for refining the methodology and confirming our results.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopaedic Surgery, Hospital for Special Surgery, Weill Cornell Medicine, New York, USA.
- Biostatistics Core, Hospital for Special Surgery, New York, USA.
- Center for Musculoskeletal Surgery, Charité - Universitätsmedizin Berlin, Berlin, Germany.
- Universitätsklinikum Ulm, Klinik für Orthopädie, Ulm, Germany.
- Department of Electrical Engineering, Technical University Berlin, Berlin, Germany.
ORCID-Profile: Ali E Guven, Alexander P Hughes
Zitieren
APA
Guven, A. E., Chiapparelli, E., Camino-Willhuber, G., Zhu, J., Schönnagel, L., Amoroso, K., Caffard, T., Erduran, A., Shue, J., Sama, A. A., Girardi, F. P., Cammisa, F. P., & Hughes, A. P. (2024). Assessing paraspinal muscle atrophy with electrical impedance myography: Limitations and insights. Journal of Orthopaedic Research. https://doi.org/10.1002/jor.25848
Vancouver
Guven AE, Chiapparelli E, Camino-Willhuber G, Zhu J, Schönnagel L, Amoroso K, et al. Assessing paraspinal muscle atrophy with electrical impedance myography: Limitations and insights. Journal of Orthopaedic Research. 2024. doi:10.1002/jor.25848
BibTeX
@article{Guven2024,
author = {Guven, Ali E and Chiapparelli, Erika and Camino-Willhuber, Gaston and Zhu, Jiaqi and Schönnagel, Lukas and Amoroso, Krizia and Caffard, Thomas and Erduran, Ada and Shue, Jennifer and Sama, Andrew A and Girardi, Federico P and Cammisa, Frank P and Hughes, Alexander P},
title = {Assessing paraspinal muscle atrophy with electrical impedance myography: Limitations and insights},
journal = {Journal of Orthopaedic Research},
year = {2024},
doi = {10.1002/jor.25848}
}
EUVIMED