EUVIMEDEUVIMED entdecken
Crossref

Force‐amplifying implant to improve key pinch strength in tendon transfer surgery: Cadaver model proof‐of‐concept

Hantao Ling iD, Kai L Roberts, Dennis Kao, Ravi Balasubramanian

Journal of Orthopaedic Research · 2023

DOI: 10.1002/jor.25511 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Orthopaedic Research, 2023. Verfasst von Hantao Ling und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Mechanical, Industrial and Manufacturing Engineering, Oregon State University, Corvallis, Oregon, USA. Hauptthemen laut MEDLINE: Tendon Transfer, Pinch Strength. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 49 Literaturangaben. Gefördert von: U.S. Department of Defense.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The brachioradialis (BR) to flexor pollicis longus (FPL) tendon transfer surgery is a common procedure used to restore key pinch grip for incomplete spinal cord injury patients. However, the procedure only restores 22% of the physiological grip strength, which is important for successfully grasping objects and minimizing fatigue. The purpose of this study was to evaluate the efficacy of using a novel force‐amplifying pulley implant to modify the standard BR to FPL tendon transfer surgery to improve key pinch grip strength in a human cadaver forearm model. A total of eight cadaveric specimens were mounted onto a custom testbed where a torque‐controlled motor actuated the BR tendon to produce key pinch grip. In each cadaver, two experimental groups were examined: a standard and an implant‐modified BR to FPL tendon transfer surgery. A force sensor mounted to the thumb recorded isometric key pinch grip forces over a range of input BR forces (2 N–25 N) applied in a ramp‐and‐hold protocol. Across the range of input BR forces, the average improvement in key pinch grip strength in the implant‐modified surgery compared to the standard surgery was 58 ± 7.1% (ranging from 41% to 64% improvement). Throughout the experiments, we observed that the implant did not hinder the movement of the BR or FPL tendons. These results suggest that a BR to FPL tendon transfer surgery utilizing a force‐amplifying pulley implant to augment force transmission can provide additional functional strength restoration over the standard procedure that directly sutures two tendons together.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tendon TransferPinch StrengthHumansQuadriplegiaTendonsThumbHand StrengthCadaver

Stichwörter der Autor:innen

hand and wristmusclesurgical repairtendontreatment

Autor:innen und Institutionen

  • School of Mechanical, Industrial and Manufacturing Engineering, Oregon State University, Corvallis, Oregon, USA.
  • Institute of Dermatology and Plastic Surgery, Cleveland Clinic, Cleveland, Ohio, USA.

ORCID-Profile: Hantao Ling

Förderung

  • U.S. Department of Defense

Zitieren

APA

Ling, H., Roberts, K. L., Kao, D., & Balasubramanian, R. (2023). Force‐amplifying implant to improve key pinch strength in tendon transfer surgery: Cadaver model proof‐of‐concept. Journal of Orthopaedic Research. https://doi.org/10.1002/jor.25511

Vancouver

Ling H, Roberts KL, Kao D, Balasubramanian R. Force‐amplifying implant to improve key pinch strength in tendon transfer surgery: Cadaver model proof‐of‐concept. Journal of Orthopaedic Research. 2023. doi:10.1002/jor.25511

BibTeX
@article{Ling2023,
  author = {Ling, Hantao and Roberts, Kai L and Kao, Dennis and Balasubramanian, Ravi},
  title = {Force‐amplifying implant to improve key pinch strength in tendon transfer surgery: Cadaver model proof‐of‐concept},
  journal = {Journal of Orthopaedic Research},
  year = {2023},
  doi = {10.1002/jor.25511}
}
Kostenlos starten →