Feasibility and Safety on Left Bundle Branch Area Pacing With Standard Stylet‐Driven Lead: ACHIEVE ‐ SYNC Multicenter Prospective Observational Cohort Study
Journal of Arrhythmia · 2026-06 · 42 (3)
DOI: 10.1002/joa3.70345 ↗Kurz gefasst
Kohortenstudie in der Zeitschrift Journal of Arrhythmia, online erschienen am 02.05.2026. Verfasst von Ga-In Yu und 12 weiteren Autor:innen. Beteiligte Einrichtung: Division of Cardiology, Gyeongsang National University Changwon Hospital Gyeongsang National University College of Medicine Changwon Republic of Kore…. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Biotronik.
Abstract (Originalsprache)
Background
Right ventricular pacing increases the risk of dyssynchrony, which raises the need for more physiological pacing strategies. Left bundle branch area pacing (LBBAP) has emerged, with most early studies utilizing lumen‐less pacing leads. The feasibility and safety of LBBAP using conventional stylet‐driven pacing lead (SDL) have been reported. We present prospective multicenter data, particularly in Asian clinical settings.
Methods
The ACHIEVE‐SYNC pilot study was a multicenter prospective observational cohort study conducted across several tertiary hospitals in South Korea. Patients with standard indications for pacemaker implantation underwent LBBAP using a 5.6Fr SDL with an extendable screw. Procedural success rate and LBBAP‐related complications were evaluated. Pacing parameters, electrocardiographic features, and echocardiographic outcomes were assessed up to 12 months after implantation.
Results
LBBAP using SDL was successful in 100 of 101 (99.0%) patients. LBBAP lead‐related adverse event occurred in 1 case (0.99%), which was lead dislodgement. The median pacing threshold at 12‐month follow‐up was 0.8 [0.7–1.0] V at 0.5 ms. At 12‐month follow‐up, the mean QRS duration changed from 119.2 ± 28.6 ms to 131.2 ± 23.8 ms. The mean left ventricular ejection fraction was 61.3% ± 8.5% before the procedure and 61.3% ± 7.5% at 12‐month follow‐up.
Conclusions
In this prospective multicenter registry, LBBAP using SDL demonstrated a near‐complete procedural success rate and a high incidence of confirmed Left bundle branch capture. Lead performance remained stable during long‐term follow‐up, and adverse events were rare, supporting the safety and technical feasibility of this approach in routine clinical practice.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Cardiology, Gyeongsang National University Changwon Hospital Gyeongsang National University College of Medicine Changwon Republic of Korea.
- Division of Cardiology, Seoul National University Hospital Seoul National University College of Medicine Seoul Republic of Korea.
- Division of Cardiology, Severance Hospital Yonsei University College of Medicine Seoul Republic of Korea.
- Division of Cardiology, Asan Medical Center Ulsan University College of Medicine Seoul Republic of Korea.
- Division of Cardiology, Sahmyook Medical Center, Seoul Hospital Sahmyook University College of Medicine Seoul Republic of Korea.
ORCID-Profile: Ga-In Yu, Tae-Hoon Kim, Daehoon Kim, Jae-Sun Uhm, Boyoung Joung
Förderung
- Biotronik
Zitieren
APA
Yu, G. I., Lee, S. R., Kim, T. H., Cho, M. S., Kim, D., Yu, H. T., Lee, J. M., Uhm, J. S., Choi, E. K., Kim, J., Joung, B., Pak, H. N., & Lee, M. H. (2026). Feasibility and Safety on Left Bundle Branch Area Pacing With Standard Stylet‐Driven Lead: ACHIEVE ‐ SYNC Multicenter Prospective Observational Cohort Study. Journal of Arrhythmia, 42(3). https://doi.org/10.1002/joa3.70345
Vancouver
Yu GI, Lee SR, Kim TH, Cho MS, Kim D, Yu HT, et al. Feasibility and Safety on Left Bundle Branch Area Pacing With Standard Stylet‐Driven Lead: ACHIEVE ‐ SYNC Multicenter Prospective Observational Cohort Study. Journal of Arrhythmia. 2026;42(3). doi:10.1002/joa3.70345
BibTeX
@article{Yu2026,
author = {Yu, Ga-In and Lee, So-Ryoung and Kim, Tae-Hoon and Cho, Min Soo and Kim, Daehoon and Yu, Hee Tae and Lee, Jung-Myung and Uhm, Jae-Sun and Choi, Eue-Keun and Kim, Jun and Joung, Boyoung and Pak, Hui-Nam and Lee, Moon-Hyoung},
title = {Feasibility and Safety on Left Bundle Branch Area Pacing With Standard Stylet‐Driven Lead: ACHIEVE ‐ SYNC Multicenter Prospective Observational Cohort Study},
journal = {Journal of Arrhythmia},
year = {2026},
volume = {42},
number = {3},
doi = {10.1002/joa3.70345}
}
EUVIMED