Clinical Outcomes on Remote Monitoring Compliance in Patients With Implantable Cardioverter Defibrillator
Journal of Arrhythmia · 2025-10 · 41 (5)
DOI: 10.1002/joa3.70203 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Arrhythmia, online erschienen am 08.10.2025. Verfasst von Vern Hsen Tan und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology Changi General Hospital Singapore Singapore. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Remote monitoring (RM) is crucial in managing patients with cardiac implantable electronic devices (CIED), and has been reported to improve clinical outcomes. The study's objective is to investigate whether compliance to RM has affected patients' long‐term clinical outcomes.
Methods
This was a prospective single‐center cohort study of consecutive patients on RM with an implantable cardioverter‐defibrillator or cardiac resynchronization therapy defibrillator followed up from 2018 to 2024. For analysis, patients were stratified according to whether they were compliant with RM. Compliance was defined as having ≥ 2 scheduled transmissions per year. Outcomes studied were the combined endpoints of all‐cause mortality or heart failure hospitalization.
Results
We analyzed 207 patients, of whom 58 (28.1%) were compliant and 149 (71.9%) were non‐compliant. Baseline demographics were similar between both arms. We observed 6.9% (4/58) of compliant patients with all‐cause mortality, compared to 15.4% (23/149) of non‐compliant patients. Four percent (2/56) of compliant patients had a hospitalization for heart failure, compared to 12.2% (18/147) of non‐compliant patients. The Kaplan–Meier analysis suggested differences in the mortality and heart failure hospitalization survival function for compliant versus non‐compliant patients. Among 166 patients with available covariate data in the multivariable exponential accelerated failure time model, the time until mortality or heart failure hospitalization was longer for compliant compared to non‐compliant patients (acceleration factor 0.24, 95% CI 0.07 to 0.81; p = 0.022).
Conclusion
RM compliance was associated with significantly lower combined end‐points of all‐cause mortality and heart failure hospitalizations, even though individual outcomes (mortality or HF hospitalization) did not reach statistical significance.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology Changi General Hospital Singapore Singapore.
- Yong Loo Lin School of Medicine National University of Singapore Singapore Singapore.
- Duke-NUS Medical School Singapore Singapore.
- Singapore Health Services Singapore Singapore.
- Department of Nursing Changi General Hospital Singapore Singapore.
- Clinical Measurement Unit Changi General Hospital Singapore Singapore.
ORCID-Profile: Vern Hsen Tan, Hui Xin See Tow, Khi Yung Fong, Colin Yeo
Zitieren
APA
Tan, V. H., See Tow, H. X., Fong, K. Y., Koh, X. H., Wang, Y., Him, A. L., Syed Hamid, S., Mok, X. R. J., Lee, L. L., Yeo, C., & Ching, C. K. (2025). Clinical Outcomes on Remote Monitoring Compliance in Patients With Implantable Cardioverter Defibrillator. Journal of Arrhythmia, 41(5). https://doi.org/10.1002/joa3.70203
Vancouver
Tan VH, See Tow HX, Fong KY, Koh XH, Wang Y, Him AL, et al. Clinical Outcomes on Remote Monitoring Compliance in Patients With Implantable Cardioverter Defibrillator. Journal of Arrhythmia. 2025;41(5). doi:10.1002/joa3.70203
BibTeX
@article{Tan2025,
author = {Tan, Vern Hsen and See Tow, Hui Xin and Fong, Khi Yung and Koh, Xuan Han and Wang, Yue and Him, Ai Ling and Syed Hamid, Sherida and Mok, Xiao Rong Joscelin and Lee, Leng Leng and Yeo, Colin and Ching, Chi Keong},
title = {Clinical Outcomes on Remote Monitoring Compliance in Patients With Implantable Cardioverter Defibrillator},
journal = {Journal of Arrhythmia},
year = {2025},
volume = {41},
number = {5},
doi = {10.1002/joa3.70203}
}
EUVIMED