Current status of wearable cardioverter‐defibrillator use in Japan
Journal of Arrhythmia · 2024-08 · 40 (4) · 998-1000
DOI: 10.1002/joa3.13113 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Arrhythmia, online erschienen am 14.07.2024. Verfasst von Reina Tonegawa-Kuji und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical and Health Information Management National Cerebral and Cardiovascular Center Suita Japan. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 3 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Japan Society for the Promotion of Science.
Abstract (Originalsprache)
Background
The current status of wearable cardiovascular defibrillators (WCD) use in Japan is unclear.
Methods
Using a nationwide claims database of Japan, we assessed characteristics of patients using WCD and factors influencing subsequent implantable cardioverter‐defibrillator (ICD) implantation.
Results
In 1049 cases, those with prior cardiopulmonary arrest (CPA) or ventricular arrhythmia, cardiomyopathy, or device‐related issues were more likely to require permanent ICDs, whereas females were less likely.
Conclusions
Prior CPA or fatal arrhythmia, underlying cardiomyopathy, or device‐related issues were associated with future permanent ICD implantation. These findings offer insights into the current status of WCD use in Japan.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Medical and Health Information Management National Cerebral and Cardiovascular Center Suita Japan.
- Department of Cardiovascular Medicine Nara Medical University Nara Japan.
- Open Innovation Center National Cerebral and Cardiovascular Center Suita Japan.
ORCID-Profile: Reina Tonegawa-Kuji
Förderung
- Japan Society for the Promotion of Science
Zitieren
APA
Tonegawa-Kuji, R., Nishida, T., Sumita, Y., Miyamoto, Y., & Kanaoka, K. (2024). Current status of wearable cardioverter‐defibrillator use in Japan. Journal of Arrhythmia, 40(4), 998-1000. https://doi.org/10.1002/joa3.13113
Vancouver
Tonegawa-Kuji R, Nishida T, Sumita Y, Miyamoto Y, Kanaoka K. Current status of wearable cardioverter‐defibrillator use in Japan. Journal of Arrhythmia. 2024;40(4):998-1000. doi:10.1002/joa3.13113
BibTeX
@article{TonegawaKuji2024,
author = {Tonegawa-Kuji, Reina and Nishida, Taku and Sumita, Yoko and Miyamoto, Yoshihiro and Kanaoka, Koshiro},
title = {Current status of wearable cardioverter‐defibrillator use in Japan},
journal = {Journal of Arrhythmia},
year = {2024},
volume = {40},
number = {4},
pages = {998--1000},
doi = {10.1002/joa3.13113}
}
EUVIMED