Single‐tube, single‐strip lateral flow assays utilizing loop‐mediated isothermal amplification for simultaneous hepatitis B and C viral detection
Journal of Medical Virology · 2024
DOI: 10.1002/jmv.29721 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Medical Virology, 2024. Verfasst von Jing-Wen Guo und 5 weiteren Autor:innen. Beteiligte Einrichtung: Institute of BioPharmaceutical Sciences, National Sun Yat-sen University, Kaohsiung, Taiwan. Hauptthemen laut MEDLINE: Nucleic Acid Amplification Techniques, Hepatitis B, Hepatitis B virus, Hepacivirus. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 32 Literaturangaben. Gefördert von: Taiwan Ministry of Science and Technology, National Sun Yat-sen University, Kaohsiung Medical University Research Center Grant.
Abstract (Originalsprache)
Globally, hepatitis B virus (HBV) affects over 250 million people, whereas hepatitis C virus (HCV) affects approximately 70 million people, posing major public health challenges. Despite the availability of vaccines and treatments, a lack of comprehensive diagnostic coverage has left many cases undiagnosed and untreated. To address the need for sensitive, specific, and accessible diagnostics, this study introduced a multiplex loop‐mediated isothermal amplification assay with lateral flow detection for simultaneous HBV and HCV testing. This assay achieved exceptional sensitivity and was capable of detecting HBV and HCV concurrently in a single tube and on a single strip within 25 min, achieving the required clinical sensitivity (10 and 10 3 genomic copies/reaction for HBV and HCV, respectively). The method was validated in clinical samples of various viral genotypes, achieving an equivalent limit of detection. Additionally, a custom portable heating device was developed for field use. The assay developed here, capable of direct viral detection on the strip, shows promise in supplanting current methods that solely identify antibodies and necessitate additional qPCR for viral activity assessment. This economical and rapid assay aligns with point‐of‐care testing needs, offering significant advancements in enhancing viral hepatitis diagnostics in settings with limited resources.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Institute of BioPharmaceutical Sciences, National Sun Yat-sen University, Kaohsiung, Taiwan.
- College of Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan.
- Department of Internal Medicine, Kaohsiung Medical University Hospital, Kaohsiung Medical University, Kaohsiung, Taiwan.
- Center for Liquid Biopsy and Cohort Research, Drug Development and Value Creation Research Center, Kaohsiung Medical University, Kaohsiung, Taiwan.
- School of Medicine, College of Medicine, National Sun Yat-sen University, Kaohsiung, Taiwan.
ORCID-Profile: Ling-Shan Yu
Förderung
- Taiwan Ministry of Science and Technology
- National Sun Yat-sen University
- Kaohsiung Medical University Research Center Grant
- Higher Education SPROUT Project
Zitieren
APA
Guo, J. W., Ho, H. Y., Dai, C. Y., Chen, Y. H., Yu, M. L., & Yu, L. S. (2024). Single‐tube, single‐strip lateral flow assays utilizing loop‐mediated isothermal amplification for simultaneous hepatitis B and C viral detection. Journal of Medical Virology. https://doi.org/10.1002/jmv.29721
Vancouver
Guo JW, Ho HY, Dai CY, Chen YH, Yu ML, Yu LS. Single‐tube, single‐strip lateral flow assays utilizing loop‐mediated isothermal amplification for simultaneous hepatitis B and C viral detection. Journal of Medical Virology. 2024. doi:10.1002/jmv.29721
BibTeX
@article{Guo2024,
author = {Guo, Jing-Wen and Ho, Hsin-Ying and Dai, Chia-Yen and Chen, Yen-Hsu and Yu, Ming-Lung and Yu, Ling-Shan},
title = {Single‐tube, single‐strip lateral flow assays utilizing loop‐mediated isothermal amplification for simultaneous hepatitis B and C viral detection},
journal = {Journal of Medical Virology},
year = {2024},
doi = {10.1002/jmv.29721}
}
EUVIMED