Clinical performance of the STANDARD M10 SARS‐CoV‐2 rapid RT‐PCR assay in patients visiting an emergency department
Journal of Medical Virology · 2023-12 · 95 (12)
DOI: 10.1002/jmv.29330 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Medical Virology, online erschienen am 20.12.2023. Verfasst von Dong-Hyun Lee und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Laboratory Medicine, Gyeongsang National University Hospital, Jinju, South Korea. Hauptthemen laut MEDLINE: SARS-CoV-2, COVID-19. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 15 Literaturangaben.
Abstract (Originalsprache)
In emergency departments, rapid screening of severe acute respiratory syndrome coronavirus 2 (SARS‐CoV‐2) was important for arranging limited isolation resources and patient care during the coronavirus disease 2019 (COVID‐19) pandemic. STANDARD M10 SARS‐CoV‐2 (SD Biosensor) is a recently developed cartridge‐based RT‐PCR that provides a turnaround time of 1 h, which is shorter than that for conventional RT‐PCR. This study evaluated the clinical performance of STANDARD M10 in patients visiting an emergency department. From March to June 2022, two specimens were collected from patients visiting an emergency department. Each specimen comprised one nasopharyngeal and one oropharyngeal swab. Respective specimens underwent rapid RT‐PCR using STANDARD M10 and conventional RT‐PCR using Allplex SARS‐CoV‐2 (Seegene). When discordant results occurred, specimens undergoing the STANDARD M10 were retested with the Allplex to exclude specimen variations. Retest results replaced initial results of the Allplex. Clinical performance of STANDARD M10 was compared with Allplex. The study enrolled 1971 patients. COVID‐19 prevalence was 6.2% based on the Allplex. Compared with the Allplex, overall agreement, positive percent agreement, and negative percent agreement of STANDARD M10 were 99.5% (95% CI: 99.1%–99.8%), 95.9% (95% CI: 90.8%–98.3%), and 99.8% (95% CI: 99.4%–99.9%), respectively. Nine discordant results were all positive on droplet digital PCR, except for one specimen that was positive with STANDARD M10. The STANDARD M10 showed reliable diagnostic performance for detecting SARS‐CoV‐2 from patients visiting in emergency departments and is a useful tool in emergency healthcare systems because of its easy‐to‐use cartridge‐based assay and short resulting time for detecting SARS‐CoV‐2.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Laboratory Medicine, Gyeongsang National University Hospital, Jinju, South Korea.
- Department of Laboratory Medicine, Daejeon St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, South Korea.
- Biostatistical Consulting and Research Laboratory, Medical Research Collaborating Center, Hanyang University, Seoul, South Korea.
- Department of Emergency Medicine, Hanyang University Guri Hospital, Hanyang University College of Medicine, Guri, South Korea.
- Department of Internal Medicine, Division of Infectious Disease, Hanyang University Guri Hospital, Hanyang University College of Medicine, Guri, South Korea.
- Department of Internal Medicine, Division of Infectious Disease, Hanyang University Guri Hospital, Guri, South Korea.
ORCID-Profile: Dong-Hyun Lee, Eunhee Han, Soorack Ryu, Hyuk Joong Choi, Jieun Kim, Jinyeong Kim, Mi Hyun Bae
Zitieren
APA
Lee, D. H., Han, E., Ryu, S., Choi, H. J., Kim, J., Kim, J., & Bae, M. H. (2023). Clinical performance of the STANDARD M10 SARS‐CoV‐2 rapid RT‐PCR assay in patients visiting an emergency department. Journal of Medical Virology, 95(12). https://doi.org/10.1002/jmv.29330
Vancouver
Lee DH, Han E, Ryu S, Choi HJ, Kim J, Kim J, et al. Clinical performance of the STANDARD M10 SARS‐CoV‐2 rapid RT‐PCR assay in patients visiting an emergency department. Journal of Medical Virology. 2023;95(12). doi:10.1002/jmv.29330
BibTeX
@article{Lee2023,
author = {Lee, Dong-Hyun and Han, Eunhee and Ryu, Soorack and Choi, Hyuk Joong and Kim, Jieun and Kim, Jinyeong and Bae, Mi Hyun},
title = {Clinical performance of the STANDARD M10 SARS‐CoV‐2 rapid RT‐PCR assay in patients visiting an emergency department},
journal = {Journal of Medical Virology},
year = {2023},
volume = {95},
number = {12},
doi = {10.1002/jmv.29330}
}
EUVIMED