EUVIMEDEUVIMED entdecken
Open Access

Enhancing the MALDI‐TOF MS Detection Mass Range of Saccharides Using a Reactive Composite Matrix

Shuyi Wang, Meiying Liu, Ling Ling iD, Chuan-Fan Ding

Journal of Mass Spectrometry · 2026

DOI: 10.1002/jms.70102 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Mass Spectrometry, 2026. Verfasst von Shuyi Wang und 3 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Advanced Mass Spectrometry and Molecular Analysis of Zhejiang Province, Institute of Mass Spectrometry, School of Material Science …. Hauptthemen laut MEDLINE: Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization, Polysaccharides. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: National Key Research and Development Program of China, Ningbo Natural Science Foundation, Natural Science Foundation of Ningbo.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry (MALDI‐TOF MS) analysis of saccharides, particularly high‐molecular‐weight polysaccharides, is often hampered by low ionization efficiency. To overcome this limitation, we developed a novel composite matrix comprising 4‐hydrazinoquinazoline (4‐HQ) and caffeic acid (CA). This matrix synergistically enhances saccharide detection: 4‐HQ specifically targets the hemiacetal termini of reducing saccharides via hydrazone formation, thereby improving ionization efficiency, while CA maintains an acidic condition for derivatization and extends the detectable mass range. Using dextran 6 k as a model, we systematically optimized the 4‐HQ/CA ratio, reaction temperature, and reaction time. The optimized 4‐HQ/CA matrix enabled direct profiling of oligo/polysaccharides in inulin and garlic extracts, as well as N‐glycans from ovalbumin and fetuin. Notably, even for non‐reducing saccharides where derivatization is precluded, 4‐HQ/CA outperformed conventional 2,5‐dihydroxybenzoic acid (DHB) by detecting more species with higher signal‐to‐noise ratios. This versatile composite matrix shows potential for robust analysis of saccharides in glycobiology and food science.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Spectrometry, Mass, Matrix-Assisted Laser Desorption-IonizationPolysaccharidesCaffeic AcidsQuinazolinesDextransInulinOvalbuminFetuins

Stichwörter der Autor:innen

4‐hydrazinoquinolinecaffeic acidcomposite matrixmatrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometrysaccharides

Substanzen

Caffeic Acidscaffeic acidQuinazolinesPolysaccharidesDextransInulinOvalbuminFetuins

Autor:innen und Institutionen

  • Key Laboratory of Advanced Mass Spectrometry and Molecular Analysis of Zhejiang Province, Institute of Mass Spectrometry, School of Material Science and Chemical Engineering, Ningbo University, Ningbo, China.
  • Technology Innovation Center of Mass Spectrometry for State Market Regulation, Center for Advanced Measurement Science, National Institute of Metrology, Beijing, China.

ORCID-Profile: Ling Ling

Förderung

  • National Key Research and Development Program of China
  • Ningbo Natural Science Foundation
  • Natural Science Foundation of Ningbo

Zitieren

APA

Wang, S., Liu, M., Ling, L., & Ding, C. F. (2026). Enhancing the MALDI‐TOF MS Detection Mass Range of Saccharides Using a Reactive Composite Matrix. Journal of Mass Spectrometry. https://doi.org/10.1002/jms.70102

Vancouver

Wang S, Liu M, Ling L, Ding CF. Enhancing the MALDI‐TOF MS Detection Mass Range of Saccharides Using a Reactive Composite Matrix. Journal of Mass Spectrometry. 2026. doi:10.1002/jms.70102

BibTeX
@article{Wang2026,
  author = {Wang, Shuyi and Liu, Meiying and Ling, Ling and Ding, Chuan-Fan},
  title = {Enhancing the MALDI‐TOF MS Detection Mass Range of Saccharides Using a Reactive Composite Matrix},
  journal = {Journal of Mass Spectrometry},
  year = {2026},
  doi = {10.1002/jms.70102}
}
Kostenlos starten →