EUVIMEDEUVIMED entdecken
Open Access

Development and Optimization of an LC–MS/MS Method for Quantification of Phosphatidylethanol in Human Whole Blood

Jacob B Nielsen, Sarrah Lahorewala, Qingwen Yang, Hai Huynh, Yuvanesh Vedaraju, Yiwei Liu iD, Roger L Bertholf, Xin Yi

Journal of Mass Spectrometry · 2026

DOI: 10.1002/jms.70083 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Mass Spectrometry, 2026. Verfasst von Jacob B Nielsen und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pathology and Genomic Medicine, Houston Methodist Hospital, Houston, Texas, USA. Hauptthemen laut MEDLINE: Tandem Mass Spectrometry, Liquid Chromatography-Mass Spectrometry, Glycerophospholipids. Die Arbeit nennt 21 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Phosphatidylethanols (PEth) are ethanol‐derived phospholipids formed in red blood cell membranes during alcohol exposure and have emerged as highly specific biomarkers for recent alcohol use. Their extended 2–4‐week detection window makes them uniquely valuable for objective monitoring in liver disease and transplantation, where accurate assessment of alcohol abstinence is critical. We developed and validated a robust liquid chromatography–tandem mass spectrometry (LC–MS/MS) assay for simultaneous quantification of PEth 16:0/18:1 and PEth 16:0/18:2 in whole blood. Multiple sample extraction strategies were evaluated to optimize recovery, sensitivity, and workflow practicality. The final method employed phospholipid‐removal cartridges in a reversed‐use configuration to retain, rather than remove, phospholipids. Wash and elution conditions were systematically optimized to achieve adequate sensitivity without a post‐extraction evaporation step, enabling direct LC–MS/MS loading after elution and automation compatibility. Due to detectable and lot‐variable endogenous PEth in commercial human blood products, multiple matrix sources were evaluated. Chicken whole blood demonstrated the cleanest background and was selected for calibrator and quality‐control preparation. The developed method achieved linearity from 10 to 1000 ng/mL ( R 2 > 0.99) with limits of quantification below 10 ng/mL, and within‐ and between‐run precision of < 10% and < 12%, respectively. Method comparison against a national reference laboratory showed excellent agreement ( R 2 ≥ 0.93; bias within ± 5%). No significant carryover, ion suppression, or lipid interference was observed. This developed and optimized LC–MS/MS method provides a sensitive, simplified, and automation‐compatible approach for PEth 16:0/18:1 and 16:0/18:2 quantification, well‐suited for high‐throughput implementation in clinical laboratories.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tandem Mass SpectrometryLiquid Chromatography-Mass SpectrometryGlycerophospholipidsHumansReproducibility of ResultsAnimalsLimit of DetectionChickensBiomarkersLinear ModelsSensitivity and Specificity

Stichwörter der Autor:innen

LC–MS/MSalcohol biomarkerliver transplantationphosphatidylethanol

Substanzen

phosphatidylethanolGlycerophospholipidsBiomarkers

Autor:innen und Institutionen

  • Department of Pathology and Genomic Medicine, Houston Methodist Hospital, Houston, Texas, USA.
  • Peoria Tazewell Pathology Group, Peoria, IL, USA.
  • Department of Pathology and Immunology, Baylor College of Medicine, Baylor St. Luke's Medical Center, Houston, Texas, USA.
  • Department of Pathology and Laboratory Medicine, Weill Cornell Medical College, New York, New York, USA.

ORCID-Profile: Yiwei Liu

Zitieren

APA

Nielsen, J. B., Lahorewala, S., Yang, Q., Huynh, H., Vedaraju, Y., Liu, Y., Bertholf, R. L., & Yi, X. (2026). Development and Optimization of an LC–MS/MS Method for Quantification of Phosphatidylethanol in Human Whole Blood. Journal of Mass Spectrometry. https://doi.org/10.1002/jms.70083

Vancouver

Nielsen JB, Lahorewala S, Yang Q, Huynh H, Vedaraju Y, Liu Y, et al. Development and Optimization of an LC–MS/MS Method for Quantification of Phosphatidylethanol in Human Whole Blood. Journal of Mass Spectrometry. 2026. doi:10.1002/jms.70083

BibTeX
@article{Nielsen2026,
  author = {Nielsen, Jacob B and Lahorewala, Sarrah and Yang, Qingwen and Huynh, Hai and Vedaraju, Yuvanesh and Liu, Yiwei and Bertholf, Roger L and Yi, Xin},
  title = {Development and Optimization of an LC–MS/MS Method for Quantification of Phosphatidylethanol in Human Whole Blood},
  journal = {Journal of Mass Spectrometry},
  year = {2026},
  doi = {10.1002/jms.70083}
}
Infokarte | EUVIMED

Artikeldaten derzeit nicht verfügbar.

Recherche