EUVIMEDEUVIMED entdecken
Crossref

Pharmacokinetic Analysis of Gatifloxacin and Dexamethasone in Rabbit Ocular Biofluid Using a Sensitive and Selective LC–MS/MS Method

Arpon Biswas, Abhijit Deb Choudhury, Anjali Mishra, Sarvesh Kumar Verma, Amol Chhatrapati Bisen, Sachin Nashik Sanap, Sristi Agrawal, Mukesh Kumar, Shivansh Kumar, Rabi Sankar Bhatta iD

Journal of Mass Spectrometry · 2024

DOI: 10.1002/jms.5088 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Mass Spectrometry, 2024. Verfasst von Arpon Biswas und 9 weiteren Autor:innen. Beteiligte Einrichtung: Pharmaceutics and Pharmacokinetic Division, CSIR-Central Drug Research Institute, Lucknow, India. Hauptthemen laut MEDLINE: Tandem Mass Spectrometry, Gatifloxacin, Dexamethasone, Tears. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 43 Literaturangaben. Gefördert von: Indian Council of Medical Research (ICMR).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Bacterial keratitis (BK) is an infection that causes inflammation of the cornea and, if severe, can result in blindness. Topical fluoroquinolones combined with corticosteroids have been shown to be useful in the treatment of BK. A rapid, selective, and sensitive bioanalytical method for simultaneous quantification of Gatifloxacin (GAT) and Dexamethasone (DEX) has been developed and validated using tandem mass spectrometry (LC–MS/MS). Optimal separation was accomplished in under 5 min using an Agilent Zorbax C18 column (100 mm × 4.6 mm, 3.5 μm). The mobile phase was composed of a blend of 0.2% formic acid in triple distilled water and methanol with a flow rate of 0.65 mL/min in isocratic mode. GAT and DEX were detected in positive electrospray ionization multiple reaction monitoring mode (MRM), and the retention time was found to be at 1.64 and 2.93 min, respectively. The linearity of GAT and DEX was found to be in the range of 1.56–400 ng mL −1 with good precision and accuracy. The method was validated according to USFDA regulatory guidelines. The validated method was effectively utilized for preclinical pharmacokinetic analysis of GAT and DEX in rabbit tear fluid following the topical application of a commercial formulation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tandem Mass SpectrometryGatifloxacinDexamethasoneTearsAnimalsRabbitsReproducibility of ResultsLimit of DetectionChromatography, LiquidMaleLinear ModelsAnti-Bacterial AgentsFluoroquinolonesOphthalmic SolutionsLiquid Chromatography-Mass Spectrometry

Stichwörter der Autor:innen

LC–MS/MSantibioticcorticosteroideye droptear fluid

Substanzen

GatifloxacinDexamethasoneAnti-Bacterial AgentsFluoroquinolonesOphthalmic Solutions

Autor:innen und Institutionen

  • Pharmaceutics and Pharmacokinetic Division, CSIR-Central Drug Research Institute, Lucknow, India.
  • Pharmaceutics and Pharmacokinetics Division of CSIR-Central Drug Research Institute, Jawaharlal Nehru University, New Delhi, India.

ORCID-Profile: Rabi Sankar Bhatta

Förderung

  • Indian Council of Medical Research (ICMR)

Zitieren

APA

Biswas, A., Choudhury, A. D., Mishra, A., Verma, S. K., Bisen, A. C., Sanap, S. N., Agrawal, S., Kumar, M., Kumar, S., & Bhatta, R. S. (2024). Pharmacokinetic Analysis of Gatifloxacin and Dexamethasone in Rabbit Ocular Biofluid Using a Sensitive and Selective LC–MS/MS Method. Journal of Mass Spectrometry. https://doi.org/10.1002/jms.5088

Vancouver

Biswas A, Choudhury AD, Mishra A, Verma SK, Bisen AC, Sanap SN, et al. Pharmacokinetic Analysis of Gatifloxacin and Dexamethasone in Rabbit Ocular Biofluid Using a Sensitive and Selective LC–MS/MS Method. Journal of Mass Spectrometry. 2024. doi:10.1002/jms.5088

BibTeX
@article{Biswas2024,
  author = {Biswas, Arpon and Choudhury, Abhijit Deb and Mishra, Anjali and Verma, Sarvesh Kumar and Bisen, Amol Chhatrapati and Sanap, Sachin Nashik and Agrawal, Sristi and Kumar, Mukesh and Kumar, Shivansh and Bhatta, Rabi Sankar},
  title = {Pharmacokinetic Analysis of Gatifloxacin and Dexamethasone in Rabbit Ocular Biofluid Using a Sensitive and Selective LC–MS/MS Method},
  journal = {Journal of Mass Spectrometry},
  year = {2024},
  doi = {10.1002/jms.5088}
}
Kostenlos starten →