EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Preliminary image evaluation performance of radiographers in one New Zealand District: a 6‐month prospective study

Kim Lewis iD, Sibusiso Mdletshe iD, Andrea Doubleday iD, Tracey Pieterse iD

Journal of Medical Radiation Sciences · 2024-12 · 71 (4) · 582-590

DOI: 10.1002/jmrs.810 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Medical Radiation Sciences, online erschienen am 26.08.2024. Verfasst von Kim Lewis und 3 weiteren Autor:innen. Beteiligte Einrichtung: Radiology Department, Te Whatu Ora Taranaki, New Plymouth, New Zealand. Hauptthemen laut MEDLINE: Radiography. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Preliminary image evaluation (PIE) is a system where radiographers alert emergency department referrers to the presence or absence of abnormalities on acute extremity X‐ray examinations. PIE and similar systems have been utilised in the United Kingdom (UK) and Australia due to a shortage of radiologists to provide a timely report. As New Zealand (NZ) faces a similar shortage, PIE should be considered to address the negative impact this has on patients. The aim of this study was to determine the effect of regular feedback and education on radiographers' performance when detecting and describing acute abnormalities on extremity X‐ray examinations in ED.

Methods

A prospective longitudinal study design was utilised for this study. The sensitivity, specificity, accuracy, and accuracy of PIEs performed by seven radiographers at a public provincial district in NZ were assessed over a 6‐month period, with the participants provided monthly results along with regular e‐mailed feedback on common errors.

Results

The mean for sensitivity, specificity, and accuracy calculated with a 95% confidence interval over the 6‐month period were 92.8% (89.9, 95.8), 94.9 (93.1, 96.8), and 94.2 (91.9, 96.5), respectively. When the month‐to‐month results were analysed, the results demonstrated an improvement in participants' sensitivity, specificity, and accuracy over the 6‐month period.

Conclusion

The results of this study demonstrated that radiographers who participated in the study can perform PIE to a high standard that is comparable with the findings from international studies and demonstrated an improvement over 6 months. Therefore, PIE may be useful in NZ to aid ED clinicians in their clinical decisions when a radiology report is unavailable.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RadiographyNew ZealandProspective StudiesHumansClinical CompetenceEmergency Service, HospitalSensitivity and SpecificityLongitudinal Studies

Stichwörter der Autor:innen

preliminary image evaluationradiographer commentingred dot

Autor:innen und Institutionen

  • Radiology Department, Te Whatu Ora Taranaki, New Plymouth, New Zealand.
  • Department of Anatomy and Medical Imaging, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand.

ORCID-Profile: Kim Lewis, Sibusiso Mdletshe, Andrea Doubleday, Tracey Pieterse

Zitieren

APA

Lewis, K., Mdletshe, S., Doubleday, A., & Pieterse, T. (2024). Preliminary image evaluation performance of radiographers in one New Zealand District: a 6‐month prospective study. Journal of Medical Radiation Sciences, 71(4), 582-590. https://doi.org/10.1002/jmrs.810

Vancouver

Lewis K, Mdletshe S, Doubleday A, Pieterse T. Preliminary image evaluation performance of radiographers in one New Zealand District: a 6‐month prospective study. Journal of Medical Radiation Sciences. 2024;71(4):582-590. doi:10.1002/jmrs.810

BibTeX
@article{Lewis2024,
  author = {Lewis, Kim and Mdletshe, Sibusiso and Doubleday, Andrea and Pieterse, Tracey},
  title = {Preliminary image evaluation performance of radiographers in one New Zealand District: a 6‐month prospective study},
  journal = {Journal of Medical Radiation Sciences},
  year = {2024},
  volume = {71},
  number = {4},
  pages = {582--590},
  doi = {10.1002/jmrs.810}
}