EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Comparing immobilisation devices in gynaecological external beam radiotherapy: improving inter‐fraction reproducibility of pelvic tilt

Shimon Prasad, Linda J Bell iD, Benjamin Zwan, Florence Ko, Tayla Blackwell, Kevin Connell, Cameron Stanton, Meegan Shepherd iD, John Atyeo iD, Mark Stevens, Marita Morgia

Journal of Medical Radiation Sciences · 2024

DOI: 10.1002/jmrs.804 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of Medical Radiation Sciences, 2024. Verfasst von Shimon Prasad und 10 weiteren Autor:innen. Beteiligte Einrichtung: Northern Sydney Cancer Centre, Radiation Oncology Department, Royal North Shore Hospital, St Leonards, New South Wales, Australia. Hauptthemen laut MEDLINE: Immobilization. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 14 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

The aim was to determine which immobilisation device improved inter‐fraction reproducibly of pelvic tilt and required the least pre‐treatment setup and planning interventions.

Methods

Sixteen patients were retrospectively reviewed, eight immobilised using the BodyFIX system (BodyFIX®, Elekta, Stockholm, Sweden) and eight using the Butterfly Board (BB) (Bionix Radiation Therapy, Toledo, OH, USA). The daily pre‐treatment images were reviewed to assess setup variations between each patient and groups for pelvic tilt, pubic symphysis, sacral promontory and the fifth lumbar spine (L5).

Results

Compared with the planning CT, pelvic tilt for most patients was within ±2° using the BodyFIX and ± 4° for the BB. The Butterfly Board had a slightly higher variance both for patient‐to‐patient (standard deviation of the systematic error) and day‐to‐day error (standard deviation of the random error). Variance in position between individual patients and the two stabilisation devices were minimal in the anterior–posterior (AP) and superior–inferior (SI) direction for the pubic symphysis, sacral promontory and L5 spine. Re‐imaged fractions due to pelvic tilt reduced by about half when BodyFIX was used (39.1% BB, 19.4% BodyFIX). One patient treated with the BB required a re‐scan for pelvic tilt. Three patients required a re‐scan for body contour variations (two using BodyFIX and one with the BB).

Conclusions

BodyFIX resulted in a more accurate inter‐fraction setup and efficient treatment and is used as the standard stabilisation for gynaecological patients at our centre. It reduced the pelvic tilt variance and reduced the need for re‐imaging pre‐treatment by half.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ImmobilizationHumansFemalePelvisMiddle AgedReproducibility of ResultsAgedRetrospective StudiesRadiotherapy Planning, Computer-AssistedTomography, X-Ray ComputedGenital Neoplasms, FemaleAdult

Stichwörter der Autor:innen

Gynaecological cancerpelvic tiltradiotherapystabilisation devices

Autor:innen und Institutionen

  • Northern Sydney Cancer Centre, Radiation Oncology Department, Royal North Shore Hospital, St Leonards, New South Wales, Australia.
  • School of Mathematical and Physical Sciences, University of Newcastle, Newcastle, New South Wales, Australia.
  • Faculty of Medicine and Health, The University of Sydney, Sydney, New South Wales, Australia.

ORCID-Profile: Linda J Bell, Meegan Shepherd, John Atyeo

Zitieren

APA

Prasad, S., Bell, L. J., Zwan, B., Ko, F., Blackwell, T., Connell, K., Stanton, C., Shepherd, M., Atyeo, J., Stevens, M., & Morgia, M. (2024). Comparing immobilisation devices in gynaecological external beam radiotherapy: improving inter‐fraction reproducibility of pelvic tilt. Journal of Medical Radiation Sciences. https://doi.org/10.1002/jmrs.804

Vancouver

Prasad S, Bell LJ, Zwan B, Ko F, Blackwell T, Connell K, et al. Comparing immobilisation devices in gynaecological external beam radiotherapy: improving inter‐fraction reproducibility of pelvic tilt. Journal of Medical Radiation Sciences. 2024. doi:10.1002/jmrs.804

BibTeX
@article{Prasad2024,
  author = {Prasad, Shimon and Bell, Linda J and Zwan, Benjamin and Ko, Florence and Blackwell, Tayla and Connell, Kevin and Stanton, Cameron and Shepherd, Meegan and Atyeo, John and Stevens, Mark and Morgia, Marita},
  title = {Comparing immobilisation devices in gynaecological external beam radiotherapy: improving inter‐fraction reproducibility of pelvic tilt},
  journal = {Journal of Medical Radiation Sciences},
  year = {2024},
  doi = {10.1002/jmrs.804}
}
Kostenlos starten →