Magnetic Resonance Guided Radiation Therapy ( MRgRT ) Prostate Motion and Margins
Journal of Medical Radiation Sciences · 2025
DOI: 10.1002/jmrs.70033 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Medical Radiation Sciences, 2025. Verfasst von Sammi Peng und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Imaging and Radiation Sciences, School of Primary and Allied Health Care, Monash University, Melbourne, Australia. Hauptthemen laut MEDLINE: Prostatic Neoplasms, Radiotherapy, Image-Guided, Magnetic Resonance Imaging, Prostate. Die Arbeit nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Introduction
Systematic and random errors in radiation dose delivery necessitate the use of planning target volume (PTV) margins to ensure adequate clinical target volume (CTV) treatment. Advances in magnetic resonance‐guided radiation therapy (MRgRT) have enabled improved imaging with possible margin reduction; however, the optimal PTV margins remain uncertain. This study aimed to evaluate the adaptive radiotherapy component of intra‐fractional prostate movement in MRgRT for prostate cancer (PCa) patients and determine appropriate PTV margins.
Methods
This study retrospectively analyzed 18 PCa patients treated using a 1.5 T MR‐Linac. The initial fusion MR and verification MR scans were registered offline to assess prostate displacement between the two scans in the anterior–posterior (AP), left‐right (LR) and superior‐inferior (SI) directions. Random and systematic errors were calculated, and the PTV margins were determined using the Van Herk formula.
Results
The average time between MR scans was 22 min (range 9–54 min) compared to an average beam‐on time of 6 min (range 2–11 min). Mean and standard deviation of translational displacement was 1.2 ± 0.9 mm in the AP, 0.6 ± 0.5 mm in the LR, and 1.1 ± 0.8 mm in the SI directions. The calculated PTV margin was 3.2 mm in AP, 1.7 mm in LR, and 3.2 mm in SI directions. There was an observed trend of increased prostate motion with increased treatment duration.
Conclusion
MRgRT facilitates PTV margin reduction for PCa; however, our findings suggest that increased on‐couch time may be associated with greater prostate motion. Future studies with larger patient cohorts and real‐time motion monitoring are recommended to optimise margin strategies.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Medical Imaging and Radiation Sciences, School of Primary and Allied Health Care, Monash University, Melbourne, Australia.
- Department of Radiation Oncology, Olivia Newton-John Cancer Wellness and Research Centre, Heidelberg, Victoria, Australia.
ORCID-Profile: Farshad Foroudi, Daryl Lim Joon
Zitieren
APA
Peng, S., Courtot, T., Lye, J., Foroudi, F., Tacey, M., Joon, D. L., Chao, M., & Choong, E. S. (2025). Magnetic Resonance Guided Radiation Therapy ( MRgRT ) Prostate Motion and Margins. Journal of Medical Radiation Sciences. https://doi.org/10.1002/jmrs.70033
Vancouver
Peng S, Courtot T, Lye J, Foroudi F, Tacey M, Joon DL, et al. Magnetic Resonance Guided Radiation Therapy ( MRgRT ) Prostate Motion and Margins. Journal of Medical Radiation Sciences. 2025. doi:10.1002/jmrs.70033
BibTeX
@article{Peng2025,
author = {Peng, Sammi and Courtot, Tegan and Lye, Jessica and Foroudi, Farshad and Tacey, Mark and Joon, Daryl Lim and Chao, Michael and Choong, Ee Siang},
title = {Magnetic Resonance Guided Radiation Therapy ( MRgRT ) Prostate Motion and Margins},
journal = {Journal of Medical Radiation Sciences},
year = {2025},
doi = {10.1002/jmrs.70033}
}
EUVIMED