EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Investigating Associations Between Signal Intensity of Silent MR Angiography and Hemodynamic Information From 4D Flow MRI in Brain Arteriovenous Malformation

Linshu Yang iD, Xiaosheng Meng iD, Haining Wei, Xiaoqian Li, Yang Yu, Qin Qin, Dan Zhu iD, Tao Hong iD, Hongqi Zhang iD, Rui Li, Jiaxing Yu, Chunxue Wu iD und 1 weitere

Journal of Magnetic Resonance Imaging · 2026-12 · 64 (6) · 1711-1723

DOI: 10.1002/jmri.70474 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Magnetic Resonance Imaging, online erschienen am 07.08.2026. Verfasst von Linshu Yang und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology and Nuclear Medicine, Xuanwu Hospital, Capital Medical University, Beijing, China. Hauptthemen laut MEDLINE: Magnetic Resonance Angiography, Intracranial Arteriovenous Malformations. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Beijing Natural Science Foundation, Beijing Physician Scientist Training Project, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Whether signal intensity (SI) on Silent MRA reflects hemodynamics in brain arteriovenous malformations (BAVMs) is unclear.

Objectives

To evaluate the relationship between Silent MRA SI and 4D flow‐derived hemodynamic parameters and examine whether Silent MRA‐based metrics are associated with symptomatic hemorrhage in BAVM. Study Type Prospective and retrospective cohort study. Subjects Patients with BAVM who underwent DSA and MRI, including a hemodynamic cohort with Silent MRA and 4D flow (40 MRI from 28 patients: 28 baseline and 12 post‐embolization follow‐up), an untreated hemorrhage analysis cohort with Silent MRA (69 patients, 26 with symptomatic hemorrhage), and 16 healthy participants. Field Strength/Sequence 3.0T MRI; Silent MRA (arterial spin labeling with zero echo time readout) and electrocardiogram‐gated 4D flow. Assessment Silent MRA SI and 4D flow‐derived average blood flow (flow avg ), maximum through‐plane velocity (V max ), and average through‐plane velocity (V avg ) were measured in intracranial arteries of healthy participants and in draining veins (DVs), feeding arteries (FAs), and non‐feeding arteries (non‐FAs) of patients. A venous burden index (VBI) was defined as normalized DV SI divided by the fourth power of DV radius. Associations between Silent MRA factors and hemorrhage were assessed before and after adjustment for age, sex, and angioarchitecture. Measurements were performed independently by two readers (15 and 5 years of experience). Statistical Test Pearson or Spearman correlation, ANOVA, logistic regression; significance level p < 0.05.

Results

Silent MRA SI correlated with flow avg in DVs ( r = 0.53), non‐FAs ( r = 0.42), and healthy arteries ( r = 0.61), but not in FAs ( p = 0.38), which exhibited higher velocities than other vessels (V avg : FAs 27.93 ± 10.32, non‐FAs 18.59 ± 7.54, DVs 12.42 ± 5.59). In hemorrhage analysis, DV ectasia (OR 0.25; 95% CI 0.09–0.70) and VBI (OR 1.42; 95% CI 1.15–1.98) were significant on univariable analysis; after multivariable adjustment, only VBI remained significant (OR 1.38; 95% CI 1.08–2.05). Data Conclusion Silent MRA SI reflected 4D flow hemodynamics in non‐FAs and DVs, but not in higher‐velocity FAs. Silent MRA‐derived VBI showed potential for noninvasive hemorrhage risk stratification in BAVM. Evidence Level 3. Technical Efficacy Stage 2.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance AngiographyIntracranial Arteriovenous MalformationsHumansFemaleMaleAdultHemodynamicsProspective StudiesMiddle AgedRetrospective StudiesBlood Flow VelocityBrainYoung AdultImaging, Three-DimensionalAdolescentCerebrovascular CirculationMagnetic Resonance Imaging

Stichwörter der Autor:innen

MR angiographyarteriovenous malformationshemodynamicshemorrhage

Autor:innen und Institutionen

  • Department of Radiology and Nuclear Medicine, Xuanwu Hospital, Capital Medical University, Beijing, China.
  • Beijing Key Laboratory of Magnetic Resonance Imaging and Brain Informatics, Beijing, China.
  • Department of Neurosurgery, Xuanwu Hospital, Capital Medical University, Beijing, China.
  • China International Neuroscience Institute, Beijing, China.
  • Center for Biomedical Imaging Research, School of Biomedical Engineering, Tsinghua University, Beijing, China.
  • Diagnostic Imaging Sciences Center (DISC), University of Washington School of Medicine, Seattle, Washington, USA.

ORCID-Profile: Linshu Yang, Xiaosheng Meng, Dan Zhu, Tao Hong, Hongqi Zhang, Chunxue Wu, Jie Lu

Förderung

  • Beijing Natural Science Foundation
  • Beijing Physician Scientist Training Project
  • National Natural Science Foundation of China
  • Natural Science Foundation of Beijing Municipality

Zitieren

APA

Yang, L., Meng, X., Wei, H., Li, X., Yu, Y., Qin, Q., Zhu, D., Hong, T., Zhang, H., Li, R., Yu, J., Wu, C., & Lu, J. (2026). Investigating Associations Between Signal Intensity of Silent MR Angiography and Hemodynamic Information From 4D Flow MRI in Brain Arteriovenous Malformation. Journal of Magnetic Resonance Imaging, 64(6), 1711-1723. https://doi.org/10.1002/jmri.70474

Vancouver

Yang L, Meng X, Wei H, Li X, Yu Y, Qin Q, et al. Investigating Associations Between Signal Intensity of Silent MR Angiography and Hemodynamic Information From 4D Flow MRI in Brain Arteriovenous Malformation. Journal of Magnetic Resonance Imaging. 2026;64(6):1711-1723. doi:10.1002/jmri.70474

BibTeX
@article{Yang2026,
  author = {Yang, Linshu and Meng, Xiaosheng and Wei, Haining and Li, Xiaoqian and Yu, Yang and Qin, Qin and Zhu, Dan and Hong, Tao and Zhang, Hongqi and Li, Rui and Yu, Jiaxing and Wu, Chunxue and Lu, Jie},
  title = {Investigating Associations Between Signal Intensity of Silent MR Angiography and Hemodynamic Information From 4D Flow MRI in Brain Arteriovenous Malformation},
  journal = {Journal of Magnetic Resonance Imaging},
  year = {2026},
  volume = {64},
  number = {6},
  pages = {1711--1723},
  doi = {10.1002/jmri.70474}
}
Kostenlos starten →