Structural MRI Volumetry Index for Differentiation of Progressive Supranuclear Palsy From Parkinson's Disease and Multiple System Atrophy by Automatic Segmentation: A Comparison With Magnetic Resonance Parkinsonism Index
Journal of Magnetic Resonance Imaging · 2026
DOI: 10.1002/jmri.70418 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Journal of Magnetic Resonance Imaging, 2026. Verfasst von Mingnan Jia und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, China. Hauptthemen laut MEDLINE: Supranuclear Palsy, Progressive, Multiple System Atrophy, Magnetic Resonance Imaging, Parkinson Disease. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 34 Literaturangaben. Gefördert von: National High Level Hospital Clinical Research Funding, Chinese Academy of Medical Sciences Innovation Fund for Medical Sciences, National Natural Science Foundation of China.
Abstract (Originalsprache)
Background
Although Parkinson's disease (PD) and Parkinsonism‐Plus syndromes (PPS) exhibit distinct brain atrophy, current clinical differentiation heavily relies on manual, plane‐specific 2D metrics, which are labor‐intensive and observer‐dependent. To fill this gap, this study developed an automated, software‐independent metric—the parkinsonism volumetric index (PDSVI)—calculated as [(pons volume × third ventricle volume)/(midbrain volume × thalamus volume) × 10].
Purpose
To evaluate the performance of PDSVI in precisely differentiating progressive supranuclear palsy (PSP) from PD, multiple system atrophy cerebellar (MSA‐C) and parkinsonian (MSA‐P) types. Study Type Retrospective. Population 246 PD, 108 PSP, 63 MSA‐C, 63 MSA‐P ( N = 480, 253 males and 227 females; mean age: 63.3 ± 9.2 years) and 252 healthy controls (HC) (134 males and 118 females; mean age: 64.9 ± 8.2 years). Field Strength/Sequence 3 T, 3D inversion‐prepared fast spoiled gradient echo sequence T1‐weighted Imaging. Assessment Manual magnetic resonance parkinsonism index (MRPI) was measured by two raters. Automated brain volumetry was performed using a pre‐trained cascaded VB‐Net. Patients were randomly assigned to training ( n = 320) and internal validation ( n = 160) cohorts via 2:1 stratified randomization. Diagnostic performance of manual MRPI, pons/midbrain volume ratio, and PDSVI were assessed. Statistical Tests Diagnostic performance was assessed via receiver operating characteristic (ROC) curve analysis and DeLong's test; p < 0.05 was considered statistically significant.
Results
In internal validation cohort, ROC analysis showed that PDSVI distinguished PSP from non‐PSP (AUC = 0.897), PD (0.873), MSA‐P (0.950), MSA‐C (0.939), and HC (0.909), comparable to manual MRPI (AUCs: 0.909, 0.886, 0.923, 0.984 and 0.862, p values: 0.760, 0.786, 0.492, 0.092, 0.287, respectively). Data Conclusion This study proposes a fully automated, 3D‐T1‐derived parameter that, while exhibiting lower sensitivity compared to the manual MRPI, provides comparable overall diagnostic performance among PSP, PD, MSA, and healthy controls. Evidence Level 3. Technical Efficacy Stage 2.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, China.
- Department of Radiology, Beijing Tiantan Hospital, Capital Medical University, Beijing, China.
- Department of Neurology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, China.
- State Key Laboratory of Complex Severe and Rare Disease, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
ORCID-Profile: Mingnan Jia, Han Wang, Mingli Li, Feng Feng
Förderung
- National High Level Hospital Clinical Research Funding
- Chinese Academy of Medical Sciences Innovation Fund for Medical Sciences
- National Natural Science Foundation of China
Zitieren
APA
Jia, M., You, H., Liu, Z., Wang, Y., Wang, H., Li, M., & Feng, F. (2026). Structural MRI Volumetry Index for Differentiation of Progressive Supranuclear Palsy From Parkinson's Disease and Multiple System Atrophy by Automatic Segmentation: A Comparison With Magnetic Resonance Parkinsonism Index. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.70418
Vancouver
Jia M, You H, Liu Z, Wang Y, Wang H, Li M, et al. Structural MRI Volumetry Index for Differentiation of Progressive Supranuclear Palsy From Parkinson's Disease and Multiple System Atrophy by Automatic Segmentation: A Comparison With Magnetic Resonance Parkinsonism Index. Journal of Magnetic Resonance Imaging. 2026. doi:10.1002/jmri.70418
BibTeX
@article{Jia2026,
author = {Jia, Mingnan and You, Hui and Liu, Zhaoxi and Wang, Yichun and Wang, Han and Li, Mingli and Feng, Feng},
title = {Structural MRI Volumetry Index for Differentiation of Progressive Supranuclear Palsy From Parkinson's Disease and Multiple System Atrophy by Automatic Segmentation: A Comparison With Magnetic Resonance Parkinsonism Index},
journal = {Journal of Magnetic Resonance Imaging},
year = {2026},
doi = {10.1002/jmri.70418}
}
EUVIMED