EUVIMEDEUVIMED entdecken
Systematische ÜbersichtMetaanalyse

Pulmonary MRI in Interstitial Lung Disease: A Systematic Review and Meta‐Analysis

Thiago de Gaultier Paulo iD, João Martins da Fonseca iD, Liana F Corrêa, Lucas Gabriel Rodrigues Pinheiro, Rubens G F Andrade iD, Gabriele C Forte iD, Borna Mehrad iD, Carina A Ruano iD, Stephan Altmayer, Liisa Bergmann, Juergen Biederer iD, Jeanne B Ackman iD und 1 weitere

Journal of Magnetic Resonance Imaging · 2026

DOI: 10.1002/jmri.70397 ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift Journal of Magnetic Resonance Imaging, 2026. Verfasst von Thiago de Gaultier Paulo und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Universidade de São Paulo, São Paulo, SP, Brazil. Hauptthemen laut MEDLINE: Lung Diseases, Interstitial, Magnetic Resonance Imaging, Lung. Die Arbeit nennt 50 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Magnetic resonance imaging (MRI) has emerged as a radiation‐free alternative for evaluating interstitial lung disease (ILD), but its diagnostic performance relative to computed tomography (CT) remains variably reported.

Purpose

To evaluate the diagnostic performance of pulmonary MRI for ILD detection and identification of key imaging hallmarks, using CT as the primary reference standard. Study Type Systematic review and meta‐analysis of observational studies. Population Twenty‐five studies including 959 participants were included in the qualitative synthesis; nine studies ( n = 473) were eligible for quantitative meta‐analysis. Field Strength/Sequence MRI field strengths ranged from 0.55 to 3.0 T and included ultrashort echo‐time (UTE), zero echo‐time (ZTE), T2‐weighted fast spin‐echo, and gradient‐echo–based sequences with slice thickness ranging from 1 to 20 mm. Assessment MRI performance was evaluated against CT for global ILD detection and imaging hallmarks including ground‐glass opacities, nodules, traction bronchiectasis, reticulations, and honeycombing. Statistical Tests Pooled sensitivity and specificity were estimated jointly using a bivariate hierarchical model of Reitsma et al.; heterogeneity was assessed with I 2 statistics ( p < 0.10). Leave‐one‐out sensitivity analyses were performed.

Results

Pooled sensitivity was 0.91 (95% CI: 0.84–0.95; I 2 : 42.1%) and pooled specificity was 0.86 (95% CI: 0.73–0.93; I 2 : 62.6%) and summary SROC AUC of 0.939. In a predefined subanalysis restricted to UTE/ZTE thin‐slice protocols (four studies), sensitivity was 0.93 (95% CI: 0.87–0.97; I 2 : 0.0%) and specificity was 0.92 (95% CI: 0.78–0.98; I 2 : 51.3%). Data Conclusion Pulmonary MRI demonstrates high diagnostic performance for ILD detection, with results suggesting protocol‐dependent performance and improved consistency under optimized UTE/ZTE thin‐slice acquisitions. Evidence Level 3. Technical Efficacy Stage 2.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Lung Diseases, InterstitialMagnetic Resonance ImagingLungHumansSensitivity and SpecificityTomography, X-Ray ComputedReproducibility of ResultsObservational Studies as Topic

Stichwörter der Autor:innen

computed tomographyinterstitial lung diseasemagnetic resonance imaging

Autor:innen und Institutionen

  • Department of Radiology, Universidade de São Paulo, São Paulo, SP, Brazil.
  • Department of Radiology, University of Florida, Gainesville, Florida, USA.
  • Department of Radiology, Pontifícia Universidade Católica do Rio Grande do Sul, Porto Alegre, Brazil.
  • NOVA Medical School, Lisbon, Portugal.
  • Department of Radiology, Stanford University, Stanford, California, USA.
  • Department of Radiology, Froedtert Hospital, Milwaukee, Wisconsin, USA.

ORCID-Profile: Thiago de Gaultier Paulo, João Martins da Fonseca, Rubens G F Andrade, Gabriele C Forte, Borna Mehrad, Carina A Ruano, Juergen Biederer, Jeanne B Ackman

Zitieren

APA

Paulo, T. G., da Fonseca, J. M., Corrêa, L. F., Pinheiro, L. G. R., Andrade, R. G. F., Forte, G. C., Mehrad, B., Ruano, C. A., Altmayer, S., Bergmann, L., Biederer, J., Ackman, J. B., & Hochhegger, B. (2026). Pulmonary MRI in Interstitial Lung Disease: A Systematic Review and Meta‐Analysis. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.70397

Vancouver

Paulo TG, da Fonseca JM, Corrêa LF, Pinheiro LGR, Andrade RGF, Forte GC, et al. Pulmonary MRI in Interstitial Lung Disease: A Systematic Review and Meta‐Analysis. Journal of Magnetic Resonance Imaging. 2026. doi:10.1002/jmri.70397

BibTeX
@article{Paulo2026,
  author = {Paulo, Thiago de Gaultier and da Fonseca, João Martins and Corrêa, Liana F and Pinheiro, Lucas Gabriel Rodrigues and Andrade, Rubens G F and Forte, Gabriele C and Mehrad, Borna and Ruano, Carina A and Altmayer, Stephan and Bergmann, Liisa and Biederer, Juergen and Ackman, Jeanne B and Hochhegger, Bruno},
  title = {Pulmonary MRI in Interstitial Lung Disease: A Systematic Review and Meta‐Analysis},
  journal = {Journal of Magnetic Resonance Imaging},
  year = {2026},
  doi = {10.1002/jmri.70397}
}
Infokarte | EUVIMED

Artikeldaten derzeit nicht verfügbar.

Recherche