EUVIMEDEUVIMED entdecken
Open Access

3D Brachial Plexus Neurography With Variable‐Rate Selective Excitation RF Pulses

Emma J McKinney iD, Xiaoying Cai, Darryl B Sneag iD, Philip G Colucci iD, Yenpo Lin, Ji Lin, Shu-Han Wang iD, Guido Buonincontri iD, Marcel Dominik Nickel iD, Nicolas Gross-Weege, Alto Stemmer iD, Peter Kollasch iD und 1 weitere

Journal of Magnetic Resonance Imaging · 2026-08 · 64 (2) · 493-501

DOI: 10.1002/jmri.70338 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Magnetic Resonance Imaging, online erschienen am 14.04.2026. Verfasst von Emma J McKinney und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology and Imaging, Hospital for Special Surgery, New York, New York, USA. Hauptthemen laut MEDLINE: Imaging, Three-Dimensional, Brachial Plexus, Magnetic Resonance Imaging, Brachial Plexus Neuropathies. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: Siemens Healthineers.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Slab‐selective radiofrequency (RF) pulses are commonly required in three‐dimensional (3D) turbo spin echo (TSE) in brachial plexus magnetic resonance neurography (MRN). However, their long selective RF pulses lead to violation of Carr–Purcell–Meiboom–Gill conditions, which might increase imaging artifacts. Hypothesis That VERSE STIR‐TSE would yield comparable motion artifact to conventional STIR‐TSE with superior nerve conspicuity and greater subjective appeal. Study Type Prospective, cross‐sectional study. Population Twenty‐four subjects (16 females; mean age: 43.7 years; range: 19–76 years) evaluated for clinical suspicion of brachial plexopathy, undergoing brachial plexus MRI (10 left, 9 right, 5 bilateral, 29 total scans analyzed). Agar phantoms mimicking nerve and muscle were also evaluated. Field Strength/Sequence 3‐Tesla, 3D STIR‐TSE with and without VERSE. Assessment Three radiologists, blinded to the sequence type and clinical data, qualitatively evaluated nerve conspicuity, motion, and preferred sequence on a 5‐point scale. Statistical Tests Wilcoxon signed‐rank tests compared nerve conspicuity (0–4 scale), motion artifact (0–4 scale), and preferred series between the non‐VERSE and VERSE pulse sequences. Gwet's AC2 assessed inter‐rater agreement. A p ‐value < 0.05 was considered statistically significant.

Results

The VERSE STIR‐TSE sequence was significantly preferred by all raters. Motion artifact was not significantly different between the sequences ( p = 0.11). Conspicuity of the suprascapular nerve was significantly greater with VERSE for both its proximal segments (median: 3, interquartile range: (2, 4), vs. 3 (1, 4)) and distal segments (4 (2, 4) vs. 3 (2, 4)), but conspicuity of the axillary nerve was not significantly different between the sequences ( p = 0.27–0.61). Phantom scans confirmed a 74% and 49% increase in signal with VERSE in the muscle and nerve‐mimicking phantoms, respectively. Data Conclusion STIR‐TSE with VERSE provided overall superior image quality for brachial plexus MRN as compared to conventional STIR‐TSE. Evidence Level 2. Technical Level 1.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Imaging, Three-DimensionalBrachial PlexusMagnetic Resonance ImagingBrachial Plexus NeuropathiesHumansFemaleAdultProspective StudiesAgedMiddle AgedCross-Sectional StudiesMalePhantoms, ImagingArtifactsYoung AdultRadio Waves

Stichwörter der Autor:innen

3DMR neurographyVERSEbrachial plexusslab‐selective

Autor:innen und Institutionen

  • Department of Radiology and Imaging, Hospital for Special Surgery, New York, New York, USA.
  • Siemens Medical Solutions USA, Inc., New York, New York, USA.
  • Chang Gung Memorial Hospital, Taoyuan, Taiwan.
  • Department of Biostatistics, Hospital for Special Surgery, New York, New York, USA.
  • Research & Clinical Translation, Magnetic Resonance, Siemens Healthineers AG, Erlangen, Germany.
  • Research & Development, Magnetic Resonance, Siemens Healthineers AG, Erlangen, Germany.

ORCID-Profile: Emma J McKinney, Darryl B Sneag, Philip G Colucci, Shu-Han Wang, Guido Buonincontri, Marcel Dominik Nickel, Alto Stemmer, Peter Kollasch, Ek T Tan

Förderung

  • Siemens Healthineers

Zitieren

APA

McKinney, E. J., Cai, X., Sneag, D. B., Colucci, P. G., Lin, Y., Lin, J., Wang, S. H., Buonincontri, G., Nickel, M. D., Gross-Weege, N., Stemmer, A., Kollasch, P., & Tan, E. T. (2026). 3D Brachial Plexus Neurography With Variable‐Rate Selective Excitation RF Pulses. Journal of Magnetic Resonance Imaging, 64(2), 493-501. https://doi.org/10.1002/jmri.70338

Vancouver

McKinney EJ, Cai X, Sneag DB, Colucci PG, Lin Y, Lin J, et al. 3D Brachial Plexus Neurography With Variable‐Rate Selective Excitation RF Pulses. Journal of Magnetic Resonance Imaging. 2026;64(2):493-501. doi:10.1002/jmri.70338

BibTeX
@article{McKinney2026,
  author = {McKinney, Emma J and Cai, Xiaoying and Sneag, Darryl B and Colucci, Philip G and Lin, Yenpo and Lin, Ji and Wang, Shu-Han and Buonincontri, Guido and Nickel, Marcel Dominik and Gross-Weege, Nicolas and Stemmer, Alto and Kollasch, Peter and Tan, Ek T},
  title = {3D Brachial Plexus Neurography With Variable‐Rate Selective Excitation RF Pulses},
  journal = {Journal of Magnetic Resonance Imaging},
  year = {2026},
  volume = {64},
  number = {2},
  pages = {493--501},
  doi = {10.1002/jmri.70338}
}
Kostenlos starten →