Exploratory 4D Flow MRI Study of Portal Venous Rotational Flow for High‐Risk Esophageal Varices in Cirrhosis
Journal of Magnetic Resonance Imaging · 2026-07 · 64 (1) · 283-293
DOI: 10.1002/jmri.70287 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Magnetic Resonance Imaging, online erschienen am 10.03.2026. Verfasst von Sungho Park und 9 weiteren Autor:innen. Beteiligte Einrichtung: Medical Device Development Center, Daegu-Gyeongbuk Medical Innovation Foundation, Daegu, Republic of Korea. Hauptthemen laut MEDLINE: Esophageal and Gastric Varices, Liver Cirrhosis, Portal Vein, Magnetic Resonance Imaging. Die Arbeit nennt 28 Literaturangaben. Gefördert von: Ministry of Science and ICT, South Korea, Korea Health Industry Development Institute, Ministry of Science, ICT and Future Planning.
Abstract (Originalsprache)
Background
Bleeding risk assessment of esophageal varices (EVs) is commonly performed in liver cirrhosis. However, existing approaches are often invasive or insufficient to fully capture bleeding risk.
Purpose
To investigate portal venous hemodynamics and vessel geometry associated with EVs severity in cirrhotic patients using four‐dimensional flow MRI as a noninvasive approach to support clinical risk assessment. Study Type Retrospective. Population One‐hundred and four cirrhotic patients consisting of patients without EVs (Group 1, n = 48), with low‐risk EVs (Group 2, n = 37), and high‐risk EVs (Group 3, n = 19). Field Strength/Sequence 3 T, a three‐directional, velocity‐encoded gradient echo sequence with Cartesian k‐space sampling. Assessment Flow rate, mean velocity, and fractional flow changes in main portal vein (PV); effective vessel diameter and vessel angle; and rotational flow including vorticity, helicity, helical flow intensity ( h 2 ), localized normalized helicity, and vortex volume. Statistical Tests One‐way ANOVA with Tukey's post hoc test or Kruskal–Wallis followed by Conover's post hoc test. Receiver operating characteristic (ROC) curve analysis. Significance level set at p < 0.05.
Results
Significant group differences were observed for flow rate at the proximal PV ( ε 2 = 0.05) and for mean PV velocity at both proximal ( ε 2 = 0.13) and distal locations ( η 2 = 0.11). In contrast, neither fractional portal venous flow nor vessel angle measurements differed across groups ( p = 0.294 and all p ≥ 0.475, respectively). Among rotational flow biomarkers, vorticity differentiated Group 3 from both Groups 1 and 2 (Group 1: 17.86 ± 3.26 s −1 , Group 2: 16.65 ± 4.58 s −1 , Group 3: 13.59 ± 3.23 s −1 ; η 2 = 0.15), with an area under the ROC curve of 0.77 (sensitivity = 0.79, specificity = 0.62). Data Conclusion Rotational flow biomarkers may support current risk assessment in cirrhotic patients with high‐risk EVs. Evidence Level 4. Technical Efficacy Stage 2.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Medical Device Development Center, Daegu-Gyeongbuk Medical Innovation Foundation, Daegu, Republic of Korea.
- Department of Radiology, Section of Pediatric Radiology, Children's Hospital Colorado, University of Colorado Anschutz Medical Campus, Aurora, Colorado, USA.
- Research Institute of Medical Sciences, Chonnam National University, Hwasun-gun, Jeollanam-do, Republic of Korea.
- Department of Radiology, Chonnam National University Medical School, Gwangju, Republic of Korea.
- Department of Radiology, Chonnam National University Hwasun Hospital, Hwasun-gun, Jeollanam-do, Republic of Korea.
- Department of Radiology, Chonnam National University Hospital, Gwangju, Republic of Korea.
ORCID-Profile: Sungho Park, Yun Young Lee, Mun Young Paek, Jae Hyun Yoon, Sang Soo Shin
Förderung
- Ministry of Science and ICT, South Korea
- Korea Health Industry Development Institute
- Ministry of Science, ICT and Future Planning
Zitieren
APA
Park, S., Man Moon, C., Kwon, M., Heo, S. H., Lee, Y. Y., Paek, M. Y., Park, S. Y., Yoon, J. H., Shin, S. S., & Huh, H. (2026). Exploratory 4D Flow MRI Study of Portal Venous Rotational Flow for High‐Risk Esophageal Varices in Cirrhosis. Journal of Magnetic Resonance Imaging, 64(1), 283-293. https://doi.org/10.1002/jmri.70287
Vancouver
Park S, Man Moon C, Kwon M, Heo SH, Lee YY, Paek MY, et al. Exploratory 4D Flow MRI Study of Portal Venous Rotational Flow for High‐Risk Esophageal Varices in Cirrhosis. Journal of Magnetic Resonance Imaging. 2026;64(1):283-293. doi:10.1002/jmri.70287
BibTeX
@article{Park2026,
author = {Park, Sungho and Man Moon, Chung and Kwon, Minseong and Heo, Suk Hee and Lee, Yun Young and Paek, Mun Young and Park, Sun Young and Yoon, Jae Hyun and Shin, Sang Soo and Huh, Hyungkyu},
title = {Exploratory 4D Flow MRI Study of Portal Venous Rotational Flow for High‐Risk Esophageal Varices in Cirrhosis},
journal = {Journal of Magnetic Resonance Imaging},
year = {2026},
volume = {64},
number = {1},
pages = {283--293},
doi = {10.1002/jmri.70287}
}
EUVIMED