Enhancing Study Design and Analysis of MR Imaging Markers Through Measurement Error Modeling
Journal of Magnetic Resonance Imaging · 2026
DOI: 10.1002/jmri.70229 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Magnetic Resonance Imaging, 2026. Verfasst von Xiaofeng Wang und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Quantitative Health Sciences, Cleveland Clinic, Cleveland, Ohio, USA. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Epilepsy, Brain, Research Design. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: NIH HHS, NIBIB NIH HHS, NCI NIH HHS.
Abstract (Originalsprache)
Background
Measurement error in imaging reduces statistical power and potentially biases parameter estimation, compromising study reliability.
Purpose
To introduce a dual data collection design (reliability and main datasets) to quantify measurement error and apply regression calibration to correct error‐prone imaging markers, thereby improving biomarker‐outcome estimation, statistical power, and sample size planning. Study Type Prospective (reliability) and retrospective (regression calibration). Population 65 healthy volunteers (mean age: 23.2), 60 age and sex matched with 34 epilepsy patients (mean age: 28.7). Field Strength/Sequence 3.0 T, MR fingerprinting (MRF) and T1‐weighted (T1w) MPRAGE. Assessment Three‐dimensional brain scan‐rescan data were acquired in 5 volunteers (6 identical acquisitions per volunteer across 3 scanners) to estimate reliability coefficients () for MRF T1 and T1w signal intensity (SI) mean and standard deviation (SD). These coefficients were applied in regression calibration to correct imaging markers in the epilepsy cohort. Effect sizes for distinguishing lesional from control were compared before and after correction. Simulations evaluated the impact of additive and proportional bias on sample size, statistical power, and association estimates under single and multi‐scanner scenarios. Statistical Test Reliability coefficient, Cohen's d , regression calibration, generalized estimation equations.
Results
MRF T1 markers exhibited higher reliability ( = 0.887–0.941) than T1w SI markers with site effects ( = 0.246–0.554). Regression calibration increased effect size more for T1w SI mean (333.22% increase) than for MRF T1 mean (12.57% increase). In multi‐site simulations, regression calibration alone achieved unbiased estimate under small site effects (additive and proportional SD ≤ 0.2), whereas under larger site effects (additive SD ≥ 0.5) only the combined regression calibration and Combat produced near‐zero bias (−0.024), outperforming naïve analysis (−0.423). Data Conclusion The dual data acquisition design with regression calibration restores attenuated imaging biomarker associations, improves statistical power, and informs sampling requirements, thus enhancing reliability and generalizability in multi‐site imaging studies. Evidence Level 3. Technical Efficacy 2.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Quantitative Health Sciences, Cleveland Clinic, Cleveland, Ohio, USA.
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio, USA.
- Medical Scientist Training Program, Case Western Reserve University School of Medicine, Cleveland, Ohio, USA.
- Heart, Vascular and Thoracic Institute, Cleveland Clinic, Cleveland, Ohio, USA.
- Epilepsy Center, Neurological Institute, Cleveland Clinic, Cleveland, Ohio, USA.
- Department of Radiology, Case Western Reserve University and University Hospitals Cleveland Medical Center, Cleveland, Ohio, USA.
ORCID-Profile: Xiaofeng Wang, Walter Zhao, Yifan Wang, Zhong Irene Wang
Förderung
- NIH HHS
- NIBIB NIH HHS
- NCI NIH HHS
- NICHD NIH HHS
- NINDS NIH HHS
- NIGMS NIH HHS
- NCATS NIH HHS
- NHLBI NIH HHS
Zitieren
APA
Wang, X., Zhao, W., Wang, Y., Kwon, D. H., Su, T. Y., Obuchowski, N. A., Griswold, M. A., Wang, Z. I., & Ma, D. (2026). Enhancing Study Design and Analysis of MR Imaging Markers Through Measurement Error Modeling. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.70229
Vancouver
Wang X, Zhao W, Wang Y, Kwon DH, Su TY, Obuchowski NA, et al. Enhancing Study Design and Analysis of MR Imaging Markers Through Measurement Error Modeling. Journal of Magnetic Resonance Imaging. 2026. doi:10.1002/jmri.70229
BibTeX
@article{Wang2026,
author = {Wang, Xiaofeng and Zhao, Walter and Wang, Yifan and Kwon, Deborah H and Su, Ting-Yu and Obuchowski, Nancy A and Griswold, Mark A and Wang, Zhong Irene and Ma, Dan},
title = {Enhancing Study Design and Analysis of MR Imaging Markers Through Measurement Error Modeling},
journal = {Journal of Magnetic Resonance Imaging},
year = {2026},
doi = {10.1002/jmri.70229}
}
EUVIMED