EUVIMEDEUVIMED entdecken
Crossref

Longitudinal In Vivo Assessment of Tibia Bone Porosity in T1DM Rabbits Using Ultrashort Echo Time MRI

Kejun Wang iD, Weiyin Vivian Liu iD, Yajun Ma iD, Zhao Wei, Haoran Lei, Chuanyun Jiang, Minzhi Pei, Yunfei Zha iD

Journal of Magnetic Resonance Imaging · 2026

DOI: 10.1002/jmri.70133 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Magnetic Resonance Imaging, 2026. Verfasst von Kejun Wang und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Renmin Hospital of Wuhan University, Wuhan, China. Hauptthemen laut MEDLINE: Tibia, Magnetic Resonance Imaging, Diabetes Mellitus, Type 1. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 49 Literaturangaben. Gefördert von: the National Natural Science Foundation of China, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Type 1 diabetes mellitus (T1DM) raises fracture risk. Longitudinal changes in cortical porosity during diabetes progression are unclear.

Purpose

To assess, using ultra short echo time (UTE)‐MRI for tibia cortical porosity and geometry changes in T1DM rabbit model, using micro‐CT (μCT) and bone remodeling biomarkers as reference. Study Type Longitudinal, animal model. Animal Model Twenty‐eight male Japanese white rabbits (age: 8–10 weeks, weight: 2.14 ± 0.24 kg) randomized to diabetic ( n = 16) and control ( n = 12) subgroups. Field Strength/Sequence 3 T; 3D dual‐echo UTE and 3D inversion recovery (IR)‐UTE sequences. Assessment UTE‐MRI were performed at baseline and multiple timepoints. Porosity index (PI), suppression ratio (SR), and cortical thickness were assessed accordingly via the signal intensity (SI) at echo time (TE) at 2.2 and 0.032 ms, SI of UTE to IR‐UTE of TE at 0.032 ms, and based on geometric modeling. μCT‐derived porosity, pore diameter, and cortical thickness were conducted at week 24. Immunohistochemistry and quantitative polymerase chain reaction (qPCR) analyzed bone remodeling markers. Statistical Tests Group comparisons were made using t tests/Mann–Whitney U tests and repeated measures ANOVA. Spearman correlation coefficients ( r ) assessed the strength of the associations between PI and bone markers. A p value < 0.05 was considered significant.

Results

24‐week T1DM rabbits had significantly UTE‐MRI‐measured higher cortical porosity (0.42 ± 0.05 vs. 0.32 ± 0.04) and lower cortical thickness (0.92 ± 0.11 vs. 1.40 ± 0.18) than the control group, consistent with μCT measurements. PI was significantly positively correlated with μCT‐measured porosity and pore diameter ( r = 0.91, 0.69, respectively), while SR showed no correlation ( r = −0.33, p = 0.11; r = −0.25, p = 0.25). PI increased significantly in T1DM rabbits from week 12 compared to the controls (0.35 ± 0.05 vs. 0.31 ± 0.04). The lower osteoblast and osteoclast‐related cell numbers and expression were negatively correlated with PI in diabetic rabbits ( r = −0.871 to −0.625). Data Conclusion UTE‐MRI has the potential to longitudinally monitor and identify early reversible cortical porosity and geometric changes. Evidence Level 1. Technical Efficacy Stage 2.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TibiaMagnetic Resonance ImagingDiabetes Mellitus, Type 1AnimalsRabbitsMalePorosityX-Ray MicrotomographyLongitudinal StudiesBone RemodelingDisease Models, AnimalImaging, Three-Dimensional

Stichwörter der Autor:innen

MRIbone remodelingbound watercortical porosityfree watertype 1 diabetesultrashort echo time

Autor:innen und Institutionen

  • Department of Radiology, Renmin Hospital of Wuhan University, Wuhan, China.
  • MR Research, GE Healthcare, Beijing, China.
  • Department of Radiology, University of California, San Diego, California, USA.
  • Instrumental Analysis Center, Shanghai Jiao Tong University, Shanghai, China.

ORCID-Profile: Kejun Wang, Weiyin Vivian Liu, Yajun Ma, Yunfei Zha

Förderung

  • the National Natural Science Foundation of China
  • National Natural Science Foundation of China

Zitieren

APA

Wang, K., Liu, W. V., Ma, Y., Wei, Z., Lei, H., Jiang, C., Pei, M., & Zha, Y. (2026). Longitudinal In Vivo Assessment of Tibia Bone Porosity in T1DM Rabbits Using Ultrashort Echo Time MRI. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.70133

Vancouver

Wang K, Liu WV, Ma Y, Wei Z, Lei H, Jiang C, et al. Longitudinal In Vivo Assessment of Tibia Bone Porosity in T1DM Rabbits Using Ultrashort Echo Time MRI. Journal of Magnetic Resonance Imaging. 2026. doi:10.1002/jmri.70133

BibTeX
@article{Wang2026,
  author = {Wang, Kejun and Liu, Weiyin Vivian and Ma, Yajun and Wei, Zhao and Lei, Haoran and Jiang, Chuanyun and Pei, Minzhi and Zha, Yunfei},
  title = {Longitudinal In Vivo Assessment of Tibia Bone Porosity in T1DM Rabbits Using Ultrashort Echo Time MRI},
  journal = {Journal of Magnetic Resonance Imaging},
  year = {2026},
  doi = {10.1002/jmri.70133}
}
Kostenlos starten →