EUVIMEDEUVIMED entdecken
Crossref

T2 ‐Weighted Imaging and Intravoxel Incoherent Motion for Monitoring Glomerulonephritis

Jian Liu iD, Yu Wu, Daoyu Yang, Xunlan Zhang, Rui Lv, Rongpin Wang, Xianchun Zeng iD

Journal of Magnetic Resonance Imaging · 2026-02 · 63 (2) · 484-496

DOI: 10.1002/jmri.70125 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Magnetic Resonance Imaging, online erschienen am 24.09.2025. Verfasst von Jian Liu und 6 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Advanced Medical Imaging and Intelligent Computing of Guizhou Province, Engineering Research Center of Text Computing and Cognitive…. Hauptthemen laut MEDLINE: Glomerulonephritis, Magnetic Resonance Imaging. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 34 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Guizhou hundred levels of personnel training program project.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Lack of reliable noninvasive diagnostic tools limits timely management of glomerulonephritis (GN), a major cause of chronic kidney disease.

Purpose

To validate the performance of intravoxel incoherent motion (IVIM) imaging and T2‐weighted imaging (T2WI) in monitoring renal injury in rats with GN. Study Type Prospective, animal model. Subjects Eighty‐one Sprague–Dawley rats (54 GN, 27 control) underwent renal MRI at nine time points from Day 2 to Week 16 (GN: n = 6; control: n = 3 per time point). Field Strength/Sequence 3.0T; IVIM and T2WI. Assessment IVIM parameters ( D , D *, f ) and standardized signal intensities (SSI) on T2WI were calculated for renal cortex and outer medulla and correlated with histology. Statistical Tests One‐way analysis of variance was used for longitudinal changes and independent t ‐test for comparing GN and controls at each time point. Receiver operating characteristic (ROC) curve analysis assessed diagnostic performance for identifying GN.

Results

Cortex, outer stripe of outer medulla (OM) and inner stripe of the outer medulla (IM) showed early SSI increase followed by gradual decline. SSI of OM was significantly higher than controls at Days 5 (2.19 ± 0.76), 10 (2.99 ± 0.34), 15 (2.46 ± 0.37), and Week 4 (2.23 ± 0.66). In GN rats, D progressively declined from Day 2 to Week 16: from 1.51 ± 0.40 to 0.91 ± 0.45 (×10 −3 mm 2 /s) in cortex, and from 1.37 ± 0.23 to 0.62 ± 0.19 (×10 −3 mm 2 /s) in outer medulla. D * and f also decreased progressively in cortex and outer medulla. Significant inverse relationships were observed between IVIM parameters and serum biomarkers ( r = −0.39 to −0.80). For diagnostic performance to identify GN, D achieved the highest area under the ROC curves in the cortex (0.926, 95% CI: 0.883–0.970) and outer medulla (0.975, 95% CI: 0.953–0.997). Data Conclusion T2WI reveals early signal changes in GN. IVIM parameters track disease progression, correlate with serum biomarkers, and distinguish GN from healthy controls. Level of Evidence 2. Technical Efficacy Stage 1.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

GlomerulonephritisMagnetic Resonance ImagingAnimalsRats, Sprague-DawleyRatsMotionMaleDisease Models, AnimalROC CurveKidneyReproducibility of ResultsProspective StudiesImage Processing, Computer-Assisted

Stichwörter der Autor:innen

T2‐weighted imagingglomerulonephritisintravoxel incoherent motionnoninvasivesignal intensity

Autor:innen und Institutionen

  • Key Laboratory of Advanced Medical Imaging and Intelligent Computing of Guizhou Province, Engineering Research Center of Text Computing and Cognitive Intelligence, Ministry of Education, State Key Laboratory of Public B…
  • Department of Nuclear Medicine, Guizhou Provincial People's Hospital, Guiyang, Guizhou, China.
  • Guizhou Province International Science and Technology Cooperation Base for Precision Imaging Diagnosis and Treatment, Key Laboratory of Advanced Medical Imaging and Intelligent Computing of Guizhou Province, Department…

ORCID-Profile: Jian Liu, Xianchun Zeng

Förderung

  • National Natural Science Foundation of China
  • Guizhou hundred levels of personnel training program project

Zitieren

APA

Liu, J., Wu, Y., Yang, D., Zhang, X., Lv, R., Wang, R., & Zeng, X. (2026). T2 ‐Weighted Imaging and Intravoxel Incoherent Motion for Monitoring Glomerulonephritis. Journal of Magnetic Resonance Imaging, 63(2), 484-496. https://doi.org/10.1002/jmri.70125

Vancouver

Liu J, Wu Y, Yang D, Zhang X, Lv R, Wang R, et al. T2 ‐Weighted Imaging and Intravoxel Incoherent Motion for Monitoring Glomerulonephritis. Journal of Magnetic Resonance Imaging. 2026;63(2):484-496. doi:10.1002/jmri.70125

BibTeX
@article{Liu2026,
  author = {Liu, Jian and Wu, Yu and Yang, Daoyu and Zhang, Xunlan and Lv, Rui and Wang, Rongpin and Zeng, Xianchun},
  title = {T2 ‐Weighted Imaging and Intravoxel Incoherent Motion for Monitoring Glomerulonephritis},
  journal = {Journal of Magnetic Resonance Imaging},
  year = {2026},
  volume = {63},
  number = {2},
  pages = {484--496},
  doi = {10.1002/jmri.70125}
}
Kostenlos starten →