Comparison of Magnetic Resonance Spectra Acquired With Hybrid PET / MR and Standalone MR Scanners

Carter B Macdonald iD, Aditya Bhattacharya iD, Benjamin B Risk iD, Taylor M Zuleger iD, Sagar Mandava iD, Ralph Noeske, Candace C Fleischer iD

Journal of Magnetic Resonance Imaging · 2025

DOI: 10.1002/jmri.70056 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of Magnetic Resonance Imaging, 2025. Verfasst von Carter B Macdonald und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, Georgia Institute of Technology and Emory University School of Medicine, Atlanta, Georgia, USA. Hauptthemen laut MEDLINE: Positron-Emission Tomography, Magnetic Resonance Imaging, Brain, Multimodal Imaging. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NINDS NIH HHS, United States National Institutes of Health (NIH) Director's New Innovator Award via the NIH Office of the Director, National Institute of Neurological Disorders and Stroke.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The effect of the positron emission tomography (PET) modality in hybrid PET/MR scanners on MR spectral quality is unclear.

Purpose

To evaluate spectral quality, quantification, and repeatability of brain MR spectroscopy (MRS) acquired on PET/MR and standalone MR scanners. Study Type Prospective. Subjects 23 healthy adults (male/female = 11/12, age = 27 ± 11 years). Field Strength/Sequence 3T, semi‐localized by adiabatic selective refocusing. Assessment Single voxel MR spectra were acquired with GE Signa PET/MR and Siemens Prisma Fit MR scanners in healthy volunteers, and additionally with a GE Premier MR scanner in vitro. Spectral quality, metabolite concentrations, and repeatability were evaluated. Statistical Tests Linear mixed models assessed signal‐to‐noise ratio (SNR), full width at half maximum (FWHM), and metabolites/total creatine (tCr). Intraclass correlation coefficients (ICCs) determined repeatability; mean squared error (MSE) evaluated accuracy of quantification. Values are reported as mean ± standard deviation. Significance was determined by p ≤ 0.05.

Results

In vivo spectra acquired using the Siemens standalone MR showed significantly higher SNR (PET/MR: 118.8 ± 19.1, MR: 132.2 ± 24.4) but significantly broader FWHM (PET/MR: 7.2 ± 1.8 Hz, MR: 8.4 ± 2.5 Hz) compared to PET/MR. All metabolite ratios were significantly higher in spectra acquired on the standalone MR. Within‐session repeatability was good (ICC > 0.75), and between‐session repeatability was moderate to excellent (ICC 0.5 to > 0.90) for all metabolites in vivo. In vitro spectra acquired with the PET/MR had significantly higher SNR (329.1 ± 46.1) than the Siemens standalone MR (150.8 ± 49.3) but significantly lower than the GE standalone MR (395.9 ± 33.7). The PET/MR produced narrower FWHM (2.1 ± 0.4 Hz) than the Siemens standalone MR (4.1 ± 1.7 Hz) but broader than the GE standalone MR (1.6 ± 0.1 Hz) and lower MSE for some metabolites. Data Conclusion MR spectral quality appears uncompromised when acquired with hybrid PET/MR compared to standalone MR.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Positron-Emission TomographyMagnetic Resonance ImagingBrainMultimodal ImagingHumansMaleFemaleAdultReproducibility of ResultsMagnetic Resonance SpectroscopySignal-To-Noise RatioProspective StudiesYoung Adult

Stichwörter der Autor:innen

MR spectroscopyPET/MRbrainhybrid MR scannersmetabolite quantification

Autor:innen und Institutionen

  • Department of Biomedical Engineering, Georgia Institute of Technology and Emory University School of Medicine, Atlanta, Georgia, USA.
  • Department of Neuroscience, Georgia Institute of Technology, Atlanta, Georgia, USA.
  • Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, Georgia, USA.
  • Department of Biostatistics and Bioinformatics, Rollins School of Public Health, Emory University, Atlanta, Georgia, USA.
  • Emory Sports Performance and Research Center (SPARC), Flowery Branch, Georgia, USA.
  • Emory Sports Medicine Center, Atlanta, Georgia, USA.

ORCID-Profile: Carter B Macdonald, Aditya Bhattacharya, Benjamin B Risk, Taylor M Zuleger, Sagar Mandava, Candace C Fleischer

Förderung

  • NINDS NIH HHS
  • United States National Institutes of Health (NIH) Director's New Innovator Award via the NIH Office of the Director
  • National Institute of Neurological Disorders and Stroke

Zitieren

APA

Macdonald, C. B., Bhattacharya, A., Risk, B. B., Zuleger, T. M., Mandava, S., Noeske, R., & Fleischer, C. C. (2025). Comparison of Magnetic Resonance Spectra Acquired With Hybrid PET / MR and Standalone MR Scanners. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.70056

Vancouver

Macdonald CB, Bhattacharya A, Risk BB, Zuleger TM, Mandava S, Noeske R, et al. Comparison of Magnetic Resonance Spectra Acquired With Hybrid PET / MR and Standalone MR Scanners. Journal of Magnetic Resonance Imaging. 2025. doi:10.1002/jmri.70056

BibTeX
@article{Macdonald2025,
  author = {Macdonald, Carter B and Bhattacharya, Aditya and Risk, Benjamin B and Zuleger, Taylor M and Mandava, Sagar and Noeske, Ralph and Fleischer, Candace C},
  title = {Comparison of Magnetic Resonance Spectra Acquired With Hybrid PET / MR and Standalone MR Scanners},
  journal = {Journal of Magnetic Resonance Imaging},
  year = {2025},
  doi = {10.1002/jmri.70056}
}
Kostenlos starten →