EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Quantitative Evaluation of Carotid Artery Stenosis by Multi‐ VENC 4D Flow MRI : Incorporating Turbulent Kinetic Energy for Clinical Validity

Takahiro Ando iD, Tetsuro Sekine, Satoshi Suda, Kentaro Suzuki, Yasuo Murai, Kotomi Iwata, Masatoki Nakaza, Masashi Ogawa, Makoto Obara, Gerard Crelier, Kazumi Kimura, Shin-Ichiro Kumita

Journal of Magnetic Resonance Imaging · 2025-10 · 62 (4) · 1168-1177

DOI: 10.1002/jmri.70008 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Magnetic Resonance Imaging, online erschienen am 29.06.2025. Verfasst von Takahiro Ando und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Nippon Medical School, Tokyo, Japan. Hauptthemen laut MEDLINE: Carotid Stenosis, Magnetic Resonance Angiography, Magnetic Resonance Imaging. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 50 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: The Japanese Society of Neuroradiology, Terumo Foundation for Life Sciences and Arts, Japan Society for the Promotion of Science.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Cervical internal carotid artery stenosis (ICS) is a recognized risk factor for ischemic stroke, yet morphological severity alone may not fully reflect hemodynamic alterations. Turbulent kinetic energy (TKE), derived from multi‐velocity‐encoding (multi‐VENC) four‐dimensional (4D) flow MRI, may provide a robust marker for ICS assessment, though its utility in carotid arteries remains underexplored.

Purpose

To investigate the reproducibility of TKE measurement and to assess correlations with MR angiography (MRA)‐derived stenosis, black blood T1‐weighted imaging (T1BB)‐derived plaque scale, and ultrasound parameters. Study Type Prospective. Population Twenty‐three patients (6 [26%] female; median age: 72 years, IQR: 60–80) with suspected ICS based on cerebrovascular symptoms or screening carotid ultrasound. Field Strength/Sequence 3‐T, multi‐VENC (33–100–300 cm/s) 4D flow MRI of the carotid arteries at 1.0 mm 3 isotropic resolution, using k‐space–time principal component analysis (k–t PCA) acceleration, time of flight‐MRA (3D gradient‐echo), and T1BB (turbo spin echo). Assessment Two neuroradiologists measured TKE once per case for interobserver evaluation. TKE was measured in a volume from just proximal to the bifurcation and slightly distal to the ICA stenosis. TKEbeat was defined as the total TKE integrated over the cardiac cycle. Stenosis and plaque features were assessed by MRA and T1BB, respectively. Carotid ultrasound parameters included peak systolic velocity, resistance index, intima‐media thickness (IMT), and plaque characteristics. Statistical Tests Intraclass correlation coefficient (ICC) and Bland–Altman analyses were used for interobserver agreements. Associations between TKEbeat and conventional parameters were evaluated using Spearman's rank correlation. TKEbeat was compared between subgroups based on stenosis, plaque grade, and vascular risk factors using Mann–Whitney U ‐tests. Significance threshold: p < 0.05.

Results

The ICC was 0.922 for TKEbeat. TKE correlated with stenosis ( r = 0.309), plaque scale ( r = 0.392), and IMT ( r = 0.543). TKEbeat was higher in the stenosis group. Data Conclusion Multi‐VENC 4D flow MRI enables reproducible TKE measurement correlated with carotid stenosis and plaque features. Evidence Level Level 1. Technical Efficacy Stage 1.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Carotid StenosisMagnetic Resonance AngiographyMagnetic Resonance ImagingHumansFemaleAgedMaleMiddle AgedReproducibility of ResultsProspective StudiesAged, 80 and overBlood Flow VelocityCarotid ArteriesCarotid Artery, InternalImage Interpretation, Computer-AssistedImaging, Three-Dimensional

Stichwörter der Autor:innen

4D flow MRIblood flow volumecarotid artery stenosisplaque characterizationturbulent kinetic energy

Autor:innen und Institutionen

  • Department of Radiology, Nippon Medical School, Tokyo, Japan.
  • Department of Neurology, Nippon Medical School, Tokyo, Japan.
  • Department of Neurological Surgery, Nippon Medical School, Tokyo, Japan.
  • Philips Electronics Japan Healthcare, Tokyo, Japan.
  • GyroTools LLC, Zurich, Switzerland.

ORCID-Profile: Takahiro Ando

Förderung

  • The Japanese Society of Neuroradiology
  • Terumo Foundation for Life Sciences and Arts
  • Japan Society for the Promotion of Science
  • Hitachi Global Foundation
  • Fukuda Foundation for Medical Technology

Zitieren

APA

Ando, T., Sekine, T., Suda, S., Suzuki, K., Murai, Y., Iwata, K., Nakaza, M., Ogawa, M., Obara, M., Crelier, G., Kimura, K., & Kumita, S. I. (2025). Quantitative Evaluation of Carotid Artery Stenosis by Multi‐ VENC 4D Flow MRI : Incorporating Turbulent Kinetic Energy for Clinical Validity. Journal of Magnetic Resonance Imaging, 62(4), 1168-1177. https://doi.org/10.1002/jmri.70008

Vancouver

Ando T, Sekine T, Suda S, Suzuki K, Murai Y, Iwata K, et al. Quantitative Evaluation of Carotid Artery Stenosis by Multi‐ VENC 4D Flow MRI : Incorporating Turbulent Kinetic Energy for Clinical Validity. Journal of Magnetic Resonance Imaging. 2025;62(4):1168-1177. doi:10.1002/jmri.70008

BibTeX
@article{Ando2025,
  author = {Ando, Takahiro and Sekine, Tetsuro and Suda, Satoshi and Suzuki, Kentaro and Murai, Yasuo and Iwata, Kotomi and Nakaza, Masatoki and Ogawa, Masashi and Obara, Makoto and Crelier, Gerard and Kimura, Kazumi and Kumita, Shin-Ichiro},
  title = {Quantitative Evaluation of Carotid Artery Stenosis by Multi‐ VENC 4D Flow MRI : Incorporating Turbulent Kinetic Energy for Clinical Validity},
  journal = {Journal of Magnetic Resonance Imaging},
  year = {2025},
  volume = {62},
  number = {4},
  pages = {1168--1177},
  doi = {10.1002/jmri.70008}
}
Kostenlos starten →