Evaluation of Real‐Time Cardiovascular Flow MRI Using Compressed Sensing in a Phantom and in Patients With Valvular Disease or Arrhythmia
Journal of Magnetic Resonance Imaging · 2025
DOI: 10.1002/jmri.29702 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Magnetic Resonance Imaging, 2025. Verfasst von Tania Lala und 8 weiteren Autor:innen. Beteiligte Einrichtung: Clinical Physiology, Department of Clinical Sciences Lund, Lund University, Skåne University Hospital, Lund, Sweden. Hauptthemen laut MEDLINE: Arrhythmias, Cardiac, Heart Valve Diseases, Magnetic Resonance Imaging, Cine, Magnetic Resonance Imaging. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Crafoordska Stiftelsen, Magnus Bergvalls Stiftelse, Maggie Stephens Foundation.
Abstract (Originalsprache)
Background
Real‐time (RT) phase contrast (PC) flow MRI can potentially be used to measure blood flow in arrhythmic patients. Undersampled RT PC has been combined with online compressed sensing (CS) reconstruction (CS RT) enabling clinical use. However, CS RT flow has not been validated in a clinical setting.
Purpose
Evaluate CS RT in phantom and patients. Study Type Prospective. Population Flow phantom (60 cycles/min: N = 10, 120 cycles/min: N = 12), sinus rhythm patients, no regurgitation (N = 20) or suspected aortic regurgitation (N = 10), arrhythmia patients (N = 10). Field Strength/Sequence 1.5 T, 2D gated PC, CS RT PC, RT cine with arrhythmia rejection. Assessment Phantom experiments tested the accuracy of CS RT cardiac output and peak flow rate at 60 and 120 cycles/min against gated PC. For sinus rhythm patients, cardiac output, peak flow rate, and regurgitation fraction in the ascending aorta and/or pulmonary artery were evaluated against gated PC. Cardiac output in patients with arrythmia was evaluated against RT cine with arrhythmia rejection. Statistical Tests Bland Altman, correlation, Mann–Whitney test, Wilcoxon signed‐rank test.
Results
Cardiac output bias ± SD for CS RT in the phantom was −0.0 ± 0.2 L/min (0.5 ± 3%, P = 0.76) at 60 cycles/min and 0.2 ± 0.3 L/min (4 ± 4%, P = 0.0016) at 120 cycles/min. Correspondingly, peak flow rate bias was −23 ± 6 mL/s (−7 ± 2%, P < 0.0001) and −73 ± 25 mL/s (−23 ± 4%, P < 0.0001). In patients, regurgitant fraction was −4 ± 0.5% (−23 ± 4%, P = 0.0025). Cardiac output bias in patients in sinus rhythm was −0.1 ± 0.5 L/min (−2 ± 10%, P = 0.99) (with regurgitation) and −0.3 ± 0.6 L/min (−5 ± 11%, P = 0.035) (without regurgitation). Peak flow rate bias was −60 ± 31 mL/s (−13 ± 6%, P < 0.0001) (with regurgitation) and −64 ± 32 mL/s (−16 ± 8%, P < 0.0001) (without regurgitation). Cardiac output bias was −0.4 ± 0.6 L/min (−9 ± 11%, P < 0.003) in arrhythmia patients. Data Conclusions CS RT flow could potentially serve as a clinical tool for patients with or without valvular disease or arrhythmia, with accurate cardiac output and regurgitation fraction quantification. Plain Language Summary Accurate flow assessment is important in clinical evaluation of cardiac patients, but in the presence of irregular heart rhythm flow assessment is challenging. We have evaluated a new method using cardiac magnetic resonance imaging and real‐time flow for blood flow assessment in cardiac patients. The method was tested against a reference method in a phantom flow model in low and high heart rates, and in cardiac patients with and without irregular heart rhythm and in different vessels. We found the cardiac magnetic resonance imaging real time flow method accurate and therefore promising for clinical implementation. Evidence Level 1 Technical Efficacy Stage 1
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Clinical Physiology, Department of Clinical Sciences Lund, Lund University, Skåne University Hospital, Lund, Sweden.
- Biomedical Engineering, Lund University, Lund, Sweden.
- Pediatric Heart Centre, Department of Clinical Sciences Lund, Lund University, Skåne University Hospital, Lund, Sweden.
- Magnetic Resonance, Siemens Healthineers AG, Erlangen, Germany.
- National Heart, Lung, and Blood Institute, Bethesda, MD, USA.
ORCID-Profile: Tania Lala, Pia Sjöberg, Johannes Töger
Förderung
- Crafoordska Stiftelsen
- Magnus Bergvalls Stiftelse
- Maggie Stephens Foundation
Zitieren
APA
Lala, T., Christierson, L., Frieberg, P., Giese, D., Kellman, P., Hakacova, N., Sjöberg, P., Ostenfeld, E., & Töger, J. (2025). Evaluation of Real‐Time Cardiovascular Flow MRI Using Compressed Sensing in a Phantom and in Patients With Valvular Disease or Arrhythmia. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.29702
Vancouver
Lala T, Christierson L, Frieberg P, Giese D, Kellman P, Hakacova N, et al. Evaluation of Real‐Time Cardiovascular Flow MRI Using Compressed Sensing in a Phantom and in Patients With Valvular Disease or Arrhythmia. Journal of Magnetic Resonance Imaging. 2025. doi:10.1002/jmri.29702
BibTeX
@article{Lala2025,
author = {Lala, Tania and Christierson, Lea and Frieberg, Petter and Giese, Daniel and Kellman, Peter and Hakacova, Nina and Sjöberg, Pia and Ostenfeld, Ellen and Töger, Johannes},
title = {Evaluation of Real‐Time Cardiovascular Flow MRI Using Compressed Sensing in a Phantom and in Patients With Valvular Disease or Arrhythmia},
journal = {Journal of Magnetic Resonance Imaging},
year = {2025},
doi = {10.1002/jmri.29702}
}
EUVIMED