Delayed Ferumoxtran‐10‐Enhanced Magnetic Resonance Neurography of the Lumbosacral Plexus: Impact on Vascular Suppression and Image Quality
Journal of Magnetic Resonance Imaging · 2025
DOI: 10.1002/jmri.29604 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Magnetic Resonance Imaging, 2025. Verfasst von Malwina Kaniewska und 4 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Diagnostic and Interventional Radiology, University Hospital Zurich (USZ), Zurich, Switzerland. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Lumbosacral Plexus, Image Enhancement, Dextrans. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 10 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: International Skeletal Society.
Abstract (Originalsprache)
Background
Intravenous Ferumoxtran‐10 belongs to ultra‐small superparamagnetic iron oxide particles and can be used for magnetic resonance neurography (MRN) as an alternative to other imaging methods which use contrast agents.
Purpose
To examine the impact of intravenous Ferumoxtran‐10 on vascular suppression and compare image quality to gadolinium (Gd)‐enhanced image acquisition in MRN of lumbosacral plexus (LS). Study Type Prospective. Population/Subjects 17 patients with Ferumoxtran‐10‐enhanced MRN, and 20 patients with Gd‐enhanced MRN. Fieldstrength/Sequence 3T/3D STIR sequence. Assessment Image quality, nerve visibility and vascular suppression were evaluated by 3 readers using a 5‐point Likert scale. Statistical Tests Inter‐reader agreement (IRA) was calculated using intraclass coefficients (ICC). Quantitative analysis of image quality was performed by signal‐to‐noise ratio (SNR) and contrast‐to‐noise ratio (CNR) measurements and compared using Student's t‐testing.
Results
Image quality, nerve visibility and vascular suppression were significantly higher for Ferumoxtran‐10‐enhanced MRN compared to Gd‐enhanced MRN sequences ( p < 0.05). IRA for image quality of nerves was good in Gd‐enhanced and Ferumoxtran‐10 MRN with ICC values of 0.76 and 0.89, respectively. IRA for nerve visibility was good in Gd‐ and Ferumoxtran‐10 enhanced MR neurography (ICC 0.72 and 0.90). Mean SNR was significantly higher in Ferumoxtran‐10‐enhanced MRN for all analyzed structures, while mean CNR was for significantly better for S1 ganglion and femoral nerve in Ferumoxtran‐10‐enhanced MRN ( p < 0.05). Data Conclusion Ferumoxtran‐10‐enhanced MRN of the LS plexus showed significantly higher image quality and nerve visibility with better vascular suppression as compared to Gd‐enhanced MRN. Evidence Level 2 Technical Efficacy Stage 3
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Institute of Diagnostic and Interventional Radiology, University Hospital Zurich (USZ), Zurich, Switzerland.
- University of Zurich (UZH), Zurich, Switzerland.
- Department of Nuclear Medicine, University Hospital Zurich, Zurich, Switzerland.
- Department of Forensic Medicine and Imaging, Institute of Forensic Medicine, University of Zurich, Zurich, Switzerland.
- Radiologie Hirslanden Zurich, Octorad AG, Zürich, Switzerland.
ORCID-Profile: Malwina Kaniewska, Eva Deininger-Czermak
Förderung
- International Skeletal Society
Zitieren
APA
Kaniewska, M., Deininger-Czermak, E., Ensle, F., Donati, O. F., & Guggenberger, R. (2025). Delayed Ferumoxtran‐10‐Enhanced Magnetic Resonance Neurography of the Lumbosacral Plexus: Impact on Vascular Suppression and Image Quality. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.29604
Vancouver
Kaniewska M, Deininger-Czermak E, Ensle F, Donati OF, Guggenberger R. Delayed Ferumoxtran‐10‐Enhanced Magnetic Resonance Neurography of the Lumbosacral Plexus: Impact on Vascular Suppression and Image Quality. Journal of Magnetic Resonance Imaging. 2025. doi:10.1002/jmri.29604
BibTeX
@article{Kaniewska2025,
author = {Kaniewska, Malwina and Deininger-Czermak, Eva and Ensle, Falko and Donati, Olivio F and Guggenberger, Roman},
title = {Delayed Ferumoxtran‐10‐Enhanced Magnetic Resonance Neurography of the Lumbosacral Plexus: Impact on Vascular Suppression and Image Quality},
journal = {Journal of Magnetic Resonance Imaging},
year = {2025},
doi = {10.1002/jmri.29604}
}
EUVIMED