Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of Magnetic Resonance Imaging, online erschienen am 21.08.2024. Verfasst von Vitali Koch und 36 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic and Interventional Radiology, Goethe University Frankfurt, University Hospital, Frankfurt am Main, Germany. Hauptthemen laut MEDLINE: Elasticity Imaging Techniques, Liver, Magnetic Resonance Imaging, Liver Diseases. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NCI NIH HHS, SiRIC InsiTu: Insights into cancer: From inflammation to tumor, Doktor Robert Pfleger-Stiftung.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Magnetic resonance elastography (MRE) can quantify tissue biomechanics noninvasively, including pathological hepatic states like metabolic dysfunction‐associated steatohepatitis.

Purpose

To compare the performance of 2D/3D‐MRE using the gravitational (GT) transducer concept with the current commercial acoustic (AC) solution utilizing a 2D‐MRE approach. Additionally, quality index markers (QIs) were proposed to identify image pixels with sufficient quality for reliably estimating tissue biomechanics. Study Type Prospective. Population One hundred seventy participants with suspected or confirmed liver disease (median age, 57 years [interquartile range (IQR), 46–65]; 66 females), and 11 healthy volunteers (median age, 31 years [IQR, 27–34]; 5 females). Field Strength/Sequence Participants were scanned twice at 1.5 T and 60 Hz vibration frequency: first, using AC‐MRE (2D‐MRE, spin‐echo EPI sequence, 11 seconds breath‐hold), and second, using GT‐MRE (2D‐ and 3D‐MRE, gradient‐echo sequence, 14 seconds breath‐hold). Assessment Image analysis was performed by four independent radiologists and one biomedical engineer. Additionally, superimposed analytic plane shear waves of known wavelength and attenuation at fixed shear modulus were used to propose pertinent QIs. Statistical Tests Spearman's correlation coefficient ( r ) was applied to assess the correlation between modalities. Interreader reproducibility was evaluated using Bland–Altman bias and reproducibility coefficients. P ‐values

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Elasticity Imaging TechniquesLiverMagnetic Resonance ImagingLiver DiseasesHumansFemaleAdultMaleProspective StudiesMiddle AgedBiomechanical PhenomenaAgedReproducibility of ResultsImaging, Three-DimensionalAcousticsImage Processing, Computer-Assisted

Stichwörter der Autor:innen

fatty liverliver fibrosismagnetic resonance elastographymagnetic resonance imagingsteatohepatitis

Autor:innen und Institutionen

  • Department of Diagnostic and Interventional Radiology, Goethe University Frankfurt, University Hospital, Frankfurt am Main, Germany.
  • Department of Radiology, Memorial Sloan Kettering Cancer Center, New York City, New York, USA.
  • Laboratory of Imaging Biomarkers, Center for Research on Inflammation, UMR 1149 INSERM, Université de Paris, Paris, France.
  • Department of Radiology, Beaujon University Hospital Paris Nord, AP-HP, Clichy, France.
  • Department of Internal Medicine I, Goethe University Frankfurt, University Hospital, Frankfurt am Main, Germany.
  • School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.

ORCID-Profile: Vitali Koch, Victoria Chernyak, Paul Konrad, Tommaso D'Angelo

Förderung

  • NCI NIH HHS
  • SiRIC InsiTu: Insights into cancer: From inflammation to tumor
  • Doktor Robert Pfleger-Stiftung
  • Agence Nationale de la Recherche

Zitieren

APA

Koch, V., Gotta, J., Chernyak, V., Cengiz, D., Torgashov, K., Eichler, K., Vilgrain, V., Martin, S. S., Ziegengeist, N. S., Konrad, P., Booz, C., Yel, I., D'Angelo, T., Mahmoudi, S., Scholtz, J. E., Bernatz, S., Alizadeh, L. S., Cimprich, M., Solim, L. A., …, & Sinkus, R. (2025). Biomechanical Assessment of Liver Integrity: Prospective Evaluation of Mechanical Versus Acoustic MR Elastography. Journal of Magnetic Resonance Imaging, 61(4), 1890-1904. https://doi.org/10.1002/jmri.29560

Vancouver

Koch V, Gotta J, Chernyak V, Cengiz D, Torgashov K, Eichler K, et al. Biomechanical Assessment of Liver Integrity: Prospective Evaluation of Mechanical Versus Acoustic MR Elastography. Journal of Magnetic Resonance Imaging. 2025;61(4):1890-1904. doi:10.1002/jmri.29560

BibTeX
@article{Koch2025,
  author = {Koch, Vitali and Gotta, Jennifer and Chernyak, Victoria and Cengiz, Duygu and Torgashov, Katerina and Eichler, Katrin and Vilgrain, Valérie and Martin, Simon S and Ziegengeist, Nicole S and Konrad, Paul and Booz, Christian and Yel, Ibrahim and D'Angelo, Tommaso and Mahmoudi, Scherwin and Scholtz, Jan-Erik and Bernatz, Simon and Alizadeh, Leona S and Cimprich, Marina and Solim, Levent A and Thalhammer, Axel and Gruber-Rouh, Tatjana and Hammerstingl, Renate M and Zeuzem, Stefan and Finkelmeier, Fabian and Pathil-Warth, Anita and Onay, Melis and Kinzler, Maximilian N and Darwish, Omar and Annio, Giacomo and Taylor, Stuart A and Wild, Peter and Dahmer, Iulia and Herrmann, Eva and Almansour, Haidara and Vogl, Thomas J and Gruenewald, Leon D and Sinkus, Ralph},
  title = {Biomechanical Assessment of Liver Integrity: Prospective Evaluation of Mechanical Versus Acoustic MR Elastography},
  journal = {Journal of Magnetic Resonance Imaging},
  year = {2025},
  volume = {61},
  number = {4},
  pages = {1890--1904},
  doi = {10.1002/jmri.29560}
}
Kostenlos starten →