EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Generalizing Diffusion Tensor Imaging of the Physis and Metaphysis

Katherine L Luo iD, Laura Santos, Rumana Tokaria, Sachin Jambawalikar, Phuong T Duong iD, José G Raya iD, Sogol Mostoufi-Moab, Diego Jaramillo

Journal of Magnetic Resonance Imaging · 2025

DOI: 10.1002/jmri.29455 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Magnetic Resonance Imaging, 2025. Verfasst von Katherine L Luo und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania, USA. Hauptthemen laut MEDLINE: Diffusion Tensor Imaging, Femur. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NIGMS NIH HHS, NIH HHS, NICHD NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Current methods to predict height potential are inaccurate. Predicting height by using MRI of the physeal cartilage has shown promise but the applicability of this technique in different imaging setups has not been well‐evaluated.

Purpose

To assess variability in diffusion tensor imaging of the physis and metaphysis (DTI‐P/M) of the distal femur between different scanners, imaging parameters, tractography software, and resolution. Study Type Prospective. Population/Subjects Eleven healthy subjects (five males and six females ages 10–16.94). Field Strength/Sequence 3 T; DTI single shot echo planar sequences. Assessment Physeal DTI tract measurements of the distal femur were compared between different scanners, imaging parameters, tractography settings, interpolation correction, and tractography software. Statistical Tests Bland–Altman, Spearman correlation, linear regression, and Shapiro–Wilk tests. Threshold for statistical significance was set at P = 0.05.

Results

DTI tract values consistently showed low variability with different imaging and analysis settings. Vendor to vendor comparison exhibited strong correlation ( ρ = 0.93) and small but significant bias (bias −5.76, limits of agreement [LOA] −24.31 to 12.78). Strong correlation and no significant difference were seen between technical replicates of the General Electric MRI scanner ( ρ = 1, bias 0.17 [LOA −1.5 to 1.2], P = 0.42) and the Siemens MRI scanner ( ρ = 0.89, bias = 0.56, P = 0.71). Different voxel sizes (1 × 1 × 2 mm 3 vs. 2 × 2 × 3 mm 3 ) did not significantly affect DTI values (bias = 1.4 [LOA −5.7 to 8.4], P = 0.35) but maintained a strong correlation ( ρ = 0.82). Gap size (0 mm vs. 0.6 mm) significantly affects tract volume (bias = 1.8 [LOA −5.4 to 1.8]) but maintains a strong correlation ( ρ = 0.93). Comparison of tractography algorithms generated significant differences in tract number, length, and volume while maintaining correlation ( ρ = 0.86, 0.99, 0.93, respectively). Comparison of interobserver variability between different tractography software also revealed significant differences while maintaining high correlation ( ρ = 0.85–0.98). Data Conclusion DTI of the pediatric physis cartilage shows high reproducibility between different imaging and analytic parameters. Evidence Level 2 Technical Efficacy Stage 1

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Diffusion Tensor ImagingFemurHumansMaleFemaleChildAdolescentProspective StudiesReproducibility of ResultsImage Processing, Computer-AssistedSoftwareBody Height

Stichwörter der Autor:innen

diffusion tensor imaginggrowth platemagnetic resonance imagingpediatric imagingphysis

Autor:innen und Institutionen

  • Department of Radiology, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania, USA.
  • Department of Radiology, Columbia University Irving Medical Center, New York, New York, USA.
  • New York University Langone Medical Center, New York, New York, USA.
  • Children's Hospital of Pennsylvania, Philadelphia, Pennsylvania, USA.

ORCID-Profile: Katherine L Luo, Phuong T Duong, José G Raya

Förderung

  • NIGMS NIH HHS
  • NIH HHS
  • NICHD NIH HHS
  • Society for Pediatric Radiology
  • National Institutes of Health

Zitieren

APA

Luo, K. L., Santos, L., Tokaria, R., Jambawalikar, S., Duong, P. T., Raya, J. G., Mostoufi-Moab, S., & Jaramillo, D. (2025). Generalizing Diffusion Tensor Imaging of the Physis and Metaphysis. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.29455

Vancouver

Luo KL, Santos L, Tokaria R, Jambawalikar S, Duong PT, Raya JG, et al. Generalizing Diffusion Tensor Imaging of the Physis and Metaphysis. Journal of Magnetic Resonance Imaging. 2025. doi:10.1002/jmri.29455

BibTeX
@article{Luo2025,
  author = {Luo, Katherine L and Santos, Laura and Tokaria, Rumana and Jambawalikar, Sachin and Duong, Phuong T and Raya, José G and Mostoufi-Moab, Sogol and Jaramillo, Diego},
  title = {Generalizing Diffusion Tensor Imaging of the Physis and Metaphysis},
  journal = {Journal of Magnetic Resonance Imaging},
  year = {2025},
  doi = {10.1002/jmri.29455}
}
Kostenlos starten →