EUVIMEDEUVIMED entdecken
Crossref

Auditory Effects of Acoustic Noise From 3‐T Brain MRI in Neonates With Hearing Protection

Chao Jin, Huifang Zhao, Huan Li, Peiyao Chen, Cong Tian, Xianjun Li, Miaomiao Wang, Congcong Liu, Qinli Sun, Jie Zheng, Baiya Li, Xihui Zhou und 2 weitere

Journal of Magnetic Resonance Imaging · 2024

DOI: 10.1002/jmri.29450 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Magnetic Resonance Imaging, 2024. Verfasst von Chao Jin und 13 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi, China. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Noise, Evoked Potentials, Auditory, Brain Stem, Hearing Loss, Noise-Induced. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 40 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Innovation Capability Support Program of Shaanxi, Clinical Research Award of the First Affiliated Hospital of Xi'an Jiaotong University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Neonates with immature auditory function (eg, weak/absent middle ear muscle reflex) could conceivably be vulnerable to noise‐induced hearing loss; however, it is unclear if neonates show evidence of hearing loss following MRI acoustic noise exposure.

Purpose

To explore the auditory effects of MRI acoustic noise in neonates. Study Type Prospective. Subjects Two independent cohorts of neonates (N = 19 and N = 18; mean gestational‐age, 38.75 ± 2.18 and 39.01 ± 1.83 weeks). Field Strength/Sequence T1‐weighted three‐dimensional gradient‐echo sequence, T2‐weighted fast spin‐echo sequence, single‐shot echo‐planar imaging‐based diffusion‐tensor imaging, single‐shot echo‐planar imaging‐based diffusion‐kurtosis imaging and T2‐weighted fluid‐attenuated inversion recovery sequence at 3.0 T. Assessment All neonates wore ear protection during scan protocols lasted ~40 minutes. Equivalent sound pressure levels (SPLs) were measured for both cohorts. In cohort1, left‐ and right‐ear auditory brainstem response (ABR) was measured before (baseline) and after (follow‐up) MRI, included assessment of ABR threshold, wave I, III and V latencies and interpeak interval to determine the functional status of auditory nerve and brainstem. In cohort2, baseline and follow‐up left‐ and right‐ear distortion product otoacoustic emission (DPOAE) amplitudes were assessed at 1.2 to 7.0 kHz to determine cochlear function. Statistical Test Wilcoxon signed‐rank or paired t ‐tests with Bonferroni's correction were used to compare the differences between baseline and follow‐up ABR and DPOAE measures.

Results

Equivalent SPLs ranged from 103.5 to 113.6 dBA. No significant differences between baseline and follow‐up were detected in left‐ or right‐ear ABR measures ( P > 0.999, Bonferroni corrected) in cohort1, or in DPOAE levels at 1.2 to 7.0 kHz in cohort2 (all P > 0.999 Bonferroni corrected except for left‐ear levels at 3.5 and 7.0 kHz with corrected P = 0.138 and P = 0.533). Data Conclusion A single 40‐minute 3‐T MRI with equivalent SPLs of 103.5–113.6 dBA did not result in significant transient disruption of auditory function, as measured by ABR and DPOAE, in neonates with adequate hearing protection. Evidence Level 2. Technical Efficacy Stage 5.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingNoiseEvoked Potentials, Auditory, Brain StemHearing Loss, Noise-InducedHumansInfant, NewbornFemaleMaleProspective StudiesEar Protective DevicesBrainCohort StudiesHearing

Stichwörter der Autor:innen

acoustic noiseauditory brainstem responseauditory functionneonateotoacoustic emission

Autor:innen und Institutionen

  • Department of Radiology, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi, China.
  • Shaanxi Engineering Research Center of Computational Imaging and Medical Intelligence, Xi'an, Shaanxi, China.
  • Department of Head-Neck-Otolaryngology, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi, China.
  • Department of Pediatrics, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi, China.
  • Center for Hearing and Deafness, University at Buffalo, Buffalo, New York, USA.

ORCID-Profile: Jian Yang

Förderung

  • National Natural Science Foundation of China
  • Innovation Capability Support Program of Shaanxi
  • Clinical Research Award of the First Affiliated Hospital of Xi'an Jiaotong University

Zitieren

APA

Jin, C., Zhao, H., Li, H., Chen, P., Tian, C., Li, X., Wang, M., Liu, C., Sun, Q., Zheng, J., Li, B., Zhou, X., Salvi, R., & Yang, J. (2024). Auditory Effects of Acoustic Noise From 3‐T Brain MRI in Neonates With Hearing Protection. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.29450

Vancouver

Jin C, Zhao H, Li H, Chen P, Tian C, Li X, et al. Auditory Effects of Acoustic Noise From 3‐T Brain MRI in Neonates With Hearing Protection. Journal of Magnetic Resonance Imaging. 2024. doi:10.1002/jmri.29450

BibTeX
@article{Jin2024,
  author = {Jin, Chao and Zhao, Huifang and Li, Huan and Chen, Peiyao and Tian, Cong and Li, Xianjun and Wang, Miaomiao and Liu, Congcong and Sun, Qinli and Zheng, Jie and Li, Baiya and Zhou, Xihui and Salvi, Richard and Yang, Jian},
  title = {Auditory Effects of Acoustic Noise From 3‐T Brain MRI in Neonates With Hearing Protection},
  journal = {Journal of Magnetic Resonance Imaging},
  year = {2024},
  doi = {10.1002/jmri.29450}
}