EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Fully Automated Valve Segmentation for Blood Flow Assessment From 4D Flow MRI Including Automated Cardiac Valve Tracking and Transvalvular Velocity Mapping

Thomas In de Braekt iD, Jean-Paul Aben, Marc Maussen, Harrie C M van den Bosch, Patrick Houthuizen, Arno A W Roest, Pieter J van den Boogaard, Hildo J Lamb iD, Jos J M Westenberg iD

Journal of Magnetic Resonance Imaging · 2025-01 · 61 (1) · 198-208

DOI: 10.1002/jmri.29370 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Magnetic Resonance Imaging, 2024-04. Verfasst von Thomas In de Braekt und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Catharina Hospital, Eindhoven, the Netherlands. Hauptthemen laut MEDLINE: Heart Valves. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Radiological Society of the Netherlands (NVvR).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Automated 4D flow MRI valvular flow quantification without time‐consuming manual segmentation might improve workflow.

Purpose

Compare automated valve segmentation (AS) to manual (MS), and manually corrected automated segmentation (AMS), in corrected atrioventricular septum defect (c‐AVSD) patients and healthy volunteers, for assessing net forward volume (NFV) and regurgitation fraction (RF). Study Type Retrospective. Population 27 c‐AVSD patients (median, 23 years; interquartile range, 16–31 years) and 24 healthy volunteers (25 years; 12.5–36.5 years). Field strength/Sequence Whole‐heart 4D flow MRI and cine steady‐state free precession at 3T. Assessment After automatic valve tracking, valve annuli were segmented on time‐resolved reformatted trans‐valvular velocity images by AS, MS, and AMS. NFV was calculated for all valves, and RF for right and left atrioventricular valves (RAVV and LAVV). NFV variation (standard deviation divided by mean NFV) and NFV differences (NFV difference of a valve vs. mean NFV of other valves) expressed internal NFV consistency. Statistical Tests Comparisons between methods were assessed by Wilcoxon signed‐rank tests, and intra/interobserver variability by intraclass correlation coefficients (ICCs). P < 0.05 was considered statistically significant, with multiple testing correction.

Results

AMS mean analysis time was significantly shorter compared with MS (5.3 ± 1.6 minutes vs. 9.1 ± 2.5 minutes). MS NFV variation (6.0%) was significantly smaller compared with AMS (6.3%), and AS (8.2%). Median NFV difference of RAVV, LAVV, PV, and AoV between segmentation methods ranged from −0.7–1.0 mL, −0.5–2.8 mL, −1.1–3.6 mL, and − 3.1–‐2.1 mL, respectively. Median RAVV and LAVV RF, between 7.1%–7.5% and 3.8%–4.3%, respectively, were not significantly different between methods. Intraobserver/interobserver agreement for AMS and MS was strong‐to‐excellent for NFV and RF (ICC ≥0.88). Data Conclusion MS demonstrates strongest internal consistency, followed closely by AMS, and AS. Automated segmentation, with or without manual correction, can be considered for 4D flow MRI valvular flow quantification. Level of Evidence 3 Technical Efficacy Stage 3

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heart ValvesHumansAdolescentFemaleAdultMaleRetrospective StudiesYoung AdultBlood Flow VelocityReproducibility of ResultsImage Processing, Computer-AssistedMagnetic Resonance Imaging, CineImaging, Three-DimensionalChildMagnetic Resonance ImagingImage Interpretation, Computer-Assisted

Stichwörter der Autor:innen

4D flow MRIautomated valve segmentationnet flow volumepostprocessing analysis timeregurgitation fraction

Autor:innen und Institutionen

  • Department of Radiology, Catharina Hospital, Eindhoven, the Netherlands.
  • Department of Radiology, Leiden University Medical Center, Leiden, the Netherlands.
  • Pie Medical Imaging BV, Maastricht, the Netherlands.
  • Department of Cardiology, Catharina Hospital, Eindhoven, the Netherlands.
  • Department of Pediatric Cardiology, Leiden University Medical Center, Leiden, the Netherlands.

ORCID-Profile: Thomas In de Braekt, Hildo J Lamb, Jos J M Westenberg

Förderung

  • Radiological Society of the Netherlands (NVvR)

Zitieren

APA

In de Braekt, T., Aben, J. P., Maussen, M., van den Bosch, H. C. M., Houthuizen, P., Roest, A. A. W., van den Boogaard, P. J., Lamb, H. J., & Westenberg, J. J. M. (2025). Fully Automated Valve Segmentation for Blood Flow Assessment From 4D Flow MRI Including Automated Cardiac Valve Tracking and Transvalvular Velocity Mapping. Journal of Magnetic Resonance Imaging, 61(1), 198-208. https://doi.org/10.1002/jmri.29370

Vancouver

In de Braekt T, Aben JP, Maussen M, van den Bosch HCM, Houthuizen P, Roest AAW, et al. Fully Automated Valve Segmentation for Blood Flow Assessment From 4D Flow MRI Including Automated Cardiac Valve Tracking and Transvalvular Velocity Mapping. Journal of Magnetic Resonance Imaging. 2025;61(1):198-208. doi:10.1002/jmri.29370

BibTeX
@article{IndeBraekt2025,
  author = {In de Braekt, Thomas and Aben, Jean-Paul and Maussen, Marc and van den Bosch, Harrie C M and Houthuizen, Patrick and Roest, Arno A W and van den Boogaard, Pieter J and Lamb, Hildo J and Westenberg, Jos J M},
  title = {Fully Automated Valve Segmentation for Blood Flow Assessment From 4D Flow MRI Including Automated Cardiac Valve Tracking and Transvalvular Velocity Mapping},
  journal = {Journal of Magnetic Resonance Imaging},
  year = {2025},
  volume = {61},
  number = {1},
  pages = {198--208},
  doi = {10.1002/jmri.29370}
}
Kostenlos starten →