EUVIMEDEUVIMED entdecken
Open Access

Simultaneous Measurement of GABA , Glutathione, and Glutamate–Glutamine in the Thalamus using Edited MR Spectroscopy: Feasibility and Applications in Traumatic Brain Injury

Xiao Liang, Muhammad G Saleh, Su Xu, Dirk Mayer, Steven Roys, Prashant Raghavan, Neeraj Badjatia, Rao P Gullapalli, Jiachen Zhuo iD

Journal of Magnetic Resonance Imaging · 2024

DOI: 10.1002/jmri.29299 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Magnetic Resonance Imaging, 2024. Verfasst von Xiao Liang und 8 weiteren Autor:innen. Beteiligte Einrichtung: Center for Advanced Imaging Research, University of Maryland School of Medicine, Baltimore, Maryland, USA. Hauptthemen laut MEDLINE: Glutamine, Thalamus, Glutamic Acid, Feasibility Studies. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NINDS NIH HHS, NIDA NIH HHS, National Institute on Drug Abuse.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

MR spectroscopy (MRS) is a noninvasive tool for evaluating biochemical alterations, such as glutamate (Glu)/gamma‐aminobutyric acid (GABA) imbalance and depletion of antioxidative glutathione (GSH) after traumatic brain injury (TBI). Thalamus, a critical and vulnerable region post‐TBI, is challenging for MRS acquisitions, necessitating optimization to simultaneously measure GABA/Glu and GSH.

Purpose

To assess the feasibility and optimize acquisition and processing approaches for simultaneously measuring GABA, Glx (Glu + glutamine (Gln)), and GSH in the thalamus, employing Hadamard encoding and reconstruction of MEscher–GArwood (MEGA)‐edited spectroscopy (HERMES). Study Type Prospective. Subjects 28 control subjects (age: 35.9 ± 15.1 years), and 17 mild TBI (mTBI) patients (age: 32.4 ± 11.3 years). Field Strength/Sequence 3T/T1‐weighted magnetization‐prepared rapid gradient‐echo (MP‐RAGE), HERMES. Assessment We evaluated the impact of acquisition with spatial saturation bands and post‐processing with spectral alignment on HERMES performance in the thalamus among controls. Within‐subject variability was examined in five controls through repeated scans within a week. The HERMES spectra in the posterior cingulate cortex (PCC) of controls were used as a reference for assessing HERMES performance in a reliable target. Furthermore, we compared metabolite levels and fitting quality in the thalamus between mTBI patients and controls. Statistical Tests Unpaired t ‐tests and within‐subject coefficient‐of‐variation (CV). A P ‐value

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

GlutamineThalamusGlutamic AcidFeasibility StudiesBrain Injuries, TraumaticMagnetic Resonance Spectroscopygamma-Aminobutyric AcidGlutathioneHumansAdultMaleFemaleProspective StudiesMiddle AgedYoung AdultMagnetic Resonance Imaging

Stichwörter der Autor:innen

GABAGSHHERMESMRSglutamatethalamus

Substanzen

GlutamineGlutamic Acidgamma-Aminobutyric AcidGlutathione

Autor:innen und Institutionen

  • Center for Advanced Imaging Research, University of Maryland School of Medicine, Baltimore, Maryland, USA.
  • Department of Diagnostic Radiology and Nuclear Medicine, University of Maryland School of Medicine, Baltimore, Maryland, USA.
  • Lurie Family Foundations MEG Imaging Center, Department of Radiology, Children's Hospital of Philadelphia, Philadelphia, Pennsylvania, USA.
  • Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
  • Department of Neurology, University of Maryland School of Medicine, Baltimore, Maryland, USA.

ORCID-Profile: Jiachen Zhuo

Förderung

  • NINDS NIH HHS
  • NIDA NIH HHS
  • National Institute on Drug Abuse
  • National Institute of Neurological Disorders and Stroke

Zitieren

APA

Liang, X., Saleh, M. G., Xu, S., Mayer, D., Roys, S., Raghavan, P., Badjatia, N., Gullapalli, R. P., & Zhuo, J. (2024). Simultaneous Measurement of GABA , Glutathione, and Glutamate–Glutamine in the Thalamus using Edited MR Spectroscopy: Feasibility and Applications in Traumatic Brain Injury. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.29299

Vancouver

Liang X, Saleh MG, Xu S, Mayer D, Roys S, Raghavan P, et al. Simultaneous Measurement of GABA , Glutathione, and Glutamate–Glutamine in the Thalamus using Edited MR Spectroscopy: Feasibility and Applications in Traumatic Brain Injury. Journal of Magnetic Resonance Imaging. 2024. doi:10.1002/jmri.29299

BibTeX
@article{Liang2024,
  author = {Liang, Xiao and Saleh, Muhammad G and Xu, Su and Mayer, Dirk and Roys, Steven and Raghavan, Prashant and Badjatia, Neeraj and Gullapalli, Rao P and Zhuo, Jiachen},
  title = {Simultaneous Measurement of GABA , Glutathione, and Glutamate–Glutamine in the Thalamus using Edited MR Spectroscopy: Feasibility and Applications in Traumatic Brain Injury},
  journal = {Journal of Magnetic Resonance Imaging},
  year = {2024},
  doi = {10.1002/jmri.29299}
}
Kostenlos starten →