EUVIMEDEUVIMED entdecken
BeobachtungsstudieOpen Access · CC BY 4.0

Reference Values for Water‐Specific T1 of the Liver at 3 T : T2*‐Compensation and the Confounding Effects of Fat

Richard B Thompson iD, Rachel Sherrington, Christian Beaulieu, Amy Kirkham, David I Paterson, Peter Seres, Justin Grenier

Journal of Magnetic Resonance Imaging · 2024

DOI: 10.1002/jmri.29262 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift Journal of Magnetic Resonance Imaging, 2024. Verfasst von Richard B Thompson und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology and Diagnostic Imaging, University of Alberta, Edmonton, Alberta, Canada. Hauptthemen laut MEDLINE: Liver, Magnetic Resonance Imaging, Water. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: CIHR, Canada Research Chairs, Canadian Institutes of Health Research.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

T1 mapping of the liver is confounded by the presence of fat. Multiparametric T1 mapping combines fat‐water separation with T1‐weighting to enable imaging of water‐specific T1 (T1 Water ), proton density fat fraction (PDFF), and T2* values. However, normative T1 Water values in the liver and its dependence on age/sex is unknown.

Purpose

Determine normative values for T1 Water in the liver with comparison to MOLLI and evaluate a T2*‐compensation approach to reduce T1 variability. Study Type Prospective observational; phantoms. Populations One hundred twenty‐four controls (56 male, 18–75 years), 50 patients at‐risk for liver disease (18 male, 30–76 years). Field Strength/Sequence 2.89 T; Saturation‐recovery chemical‐shift encoded T1 Mapping (SR‐CSE); MOLLI. Assessment SR‐CSE provided T1 Water measurements, PDFF and T2* values in the liver across three slices in 6 seconds. These were compared with MOLLI T1 values. A new T2*‐compensation approach to reduce T1 variability was evaluated test/re‐test reproducibility. Statistical Tests Linear regression, ANCOVA, t ‐test, Bland and Altman, intraclass correlation coefficient (ICC). P < 0.05 was considered statistically significant.

Results

Liver T1 values were significantly higher in healthy females (F) than males (M) for both SR‐CSE (F‐973 ± 78 msec, M‐930 ± 72 msec) and MOLLI (F‐802 ± 55 msec, M‐759 ± 69 msec). T1 values were negatively correlated with age, with similar sex‐ and age‐dependencies observed in T2*. The T2*‐compensation model reduced the variability of T1 values by half and removed sex‐ and age‐differences (SR‐CSE: F‐946 ± 36 msec, M‐941 ± 43 msec; MOLLI: F‐775 ± 35 msec, M‐770 ± 35 msec). At‐risk participants had elevated PDFF and T1 values, which became more distinct from the healthy cohort after T2*‐compensation. MOLLI systematically underestimated liver T1 values by ~170 msec with an additional positive T1‐bias from fat content (~11 msec/1% in PDFF). Reproducibility ICC values were ≥0.96 for all parameters. Data Conclusion Liver T1 Water values were lower in males and decreased with age, as observed for SR‐CSE and MOLLI acquisitions. MOLLI underestimated liver T1 with an additional large positive fat‐modulated T1 bias. T2*‐compensation removed sex‐ and age‐dependence in liver T1, reduced the range of healthy values and increased T1 group differences between healthy and at‐risk groups. Evidence Level 2 Technical Efficacy Stage 1

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

LiverMagnetic Resonance ImagingWaterHumansMaleFemaleMiddle AgedAdultReference ValuesAgedAdolescentReproducibility of ResultsYoung AdultProspective StudiesAdipose TissuePhantoms, Imaging

Stichwörter der Autor:innen

MOLLIMRIPDFFSR‐CSET1 mappingT2*liver

Substanzen

Water

Autor:innen und Institutionen

  • Department of Radiology and Diagnostic Imaging, University of Alberta, Edmonton, Alberta, Canada.
  • Department of Biomedical Engineering, University of Alberta, Edmonton, Alberta, Canada.
  • Faculty of Kinesiology & Physical Education, University of Toronto, Toronto, Ontario, Canada.
  • Division of Cardiology, University of Ottawa Heart Institute, Ottawa, Ontario, Canada.

ORCID-Profile: Richard B Thompson

Förderung

  • CIHR
  • Canada Research Chairs
  • Canadian Institutes of Health Research

Zitieren

APA

Thompson, R. B., Sherrington, R., Beaulieu, C., Kirkham, A., Paterson, D. I., Seres, P., & Grenier, J. (2024). Reference Values for Water‐Specific T1 of the Liver at 3 T : T2*‐Compensation and the Confounding Effects of Fat. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.29262

Vancouver

Thompson RB, Sherrington R, Beaulieu C, Kirkham A, Paterson DI, Seres P, et al. Reference Values for Water‐Specific T1 of the Liver at 3 T : T2*‐Compensation and the Confounding Effects of Fat. Journal of Magnetic Resonance Imaging. 2024. doi:10.1002/jmri.29262

BibTeX
@article{Thompson2024,
  author = {Thompson, Richard B and Sherrington, Rachel and Beaulieu, Christian and Kirkham, Amy and Paterson, David I and Seres, Peter and Grenier, Justin},
  title = {Reference Values for Water‐Specific T1 of the Liver at 3 T : T2*‐Compensation and the Confounding Effects of Fat},
  journal = {Journal of Magnetic Resonance Imaging},
  year = {2024},
  doi = {10.1002/jmri.29262}
}
Kostenlos starten →