Automated Breast Density Assessment in MRI Using Deep Learning and Radiomics: Strategies for Reducing Inter‐Observer Variability
Journal of Magnetic Resonance Imaging · 2024
DOI: 10.1002/jmri.29058 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Magnetic Resonance Imaging, 2024. Verfasst von Xueping Jing und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands. Hauptthemen laut MEDLINE: Deep Learning, Observer Variation, Magnetic Resonance Imaging, Breast Density. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Background
Accurate breast density evaluation allows for more precise risk estimation but suffers from high inter‐observer variability.
Purpose
To evaluate the feasibility of reducing inter‐observer variability of breast density assessment through artificial intelligence (AI) assisted interpretation. Study Type Retrospective. Population Six hundred and twenty‐one patients without breast prosthesis or reconstructions were randomly divided into training (N = 377), validation (N = 98), and independent test (N = 146) datasets. Field Strength/Sequence 1.5 T and 3.0 T; T1‐weighted spectral attenuated inversion recovery. Assessment Five radiologists independently assessed each scan in the independent test set to establish the inter‐observer variability baseline and to reach a reference standard. Deep learning and three radiomics models were developed for three classification tasks: (i) four Breast Imaging‐Reporting and Data System (BI‐RADS) breast composition categories (A–D), (ii) dense (categories C, D) vs. non‐dense (categories A, B), and (iii) extremely dense (category D) vs. moderately dense (categories A–C). The models were tested against the reference standard on the independent test set. AI‐assisted interpretation was performed by majority voting between the models and each radiologist's assessment. Statistical Tests Inter‐observer variability was assessed using linear‐weighted kappa ( κ ) statistics. Kappa statistics, accuracy, and area under the receiver operating characteristic curve (AUC) were used to assess models against reference standard.
Results
In the independent test set, five readers showed an overall substantial agreement on tasks (i) and (ii), but moderate agreement for task (iii). The best‐performing model showed substantial agreement with reference standard for tasks (i) and (ii), but moderate agreement for task (iii). With the assistance of the AI models, almost perfect inter‐observer variability was obtained for tasks (i) (mean κ = 0.86), (ii) (mean κ = 0.94), and (iii) (mean κ = 0.94). Data Conclusion Deep learning and radiomics models have the potential to help reduce inter‐observer variability of breast density assessment. Level of Evidence 3 Technical Efficacy Stage 1
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiation Oncology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands.
- Machine Learning Lab, Data Science Center in Health (DASH), University Medical Center Groningen, University of Groningen, Groningen, The Netherlands.
- Department of Radiology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands.
- Faculty of Medical Sciences, University of Groningen, Groningen, The Netherlands.
- Institute of Diagnostic Accuracy Research B.V., Groningen, The Netherlands.
ORCID-Profile: Xueping Jing, Mirjam Wielema
Zitieren
APA
Jing, X., Wielema, M., Monroy-Gonzalez, A. G., Stams, T. R. G., Mahesh, S. V. K., Oudkerk, M., Sijens, P. E., Dorrius, M. D., & van Ooijen, P. M. A. (2024). Automated Breast Density Assessment in MRI Using Deep Learning and Radiomics: Strategies for Reducing Inter‐Observer Variability. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.29058
Vancouver
Jing X, Wielema M, Monroy-Gonzalez AG, Stams TRG, Mahesh SVK, Oudkerk M, et al. Automated Breast Density Assessment in MRI Using Deep Learning and Radiomics: Strategies for Reducing Inter‐Observer Variability. Journal of Magnetic Resonance Imaging. 2024. doi:10.1002/jmri.29058
BibTeX
@article{Jing2024,
author = {Jing, Xueping and Wielema, Mirjam and Monroy-Gonzalez, Andrea G and Stams, Thom R G and Mahesh, Shekar V K and Oudkerk, Matthijs and Sijens, Paul E and Dorrius, Monique D and van Ooijen, Peter M A},
title = {Automated Breast Density Assessment in MRI Using Deep Learning and Radiomics: Strategies for Reducing Inter‐Observer Variability},
journal = {Journal of Magnetic Resonance Imaging},
year = {2024},
doi = {10.1002/jmri.29058}
}
EUVIMED