EUVIMEDEUVIMED entdecken
Beobachtungsstudie

Blood Oxygen Level‐Dependent MR Imaging of Lower Extremities in Peripheral Artery Disease and Its Correlation With Walking Performance

Xiaoxi Yu iD, Zhaoxi Liu, Jiang Shao, Jianxun Qu, Zhichao Lai, Ling Yuan, Jiangyu Ma, Xiaoyuan Fan iD, Luming Ye, Kang Li, Yan Zhang, Fengdan Wang und 3 weitere

Journal of Magnetic Resonance Imaging · 2024

DOI: 10.1002/jmri.28757 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift Journal of Magnetic Resonance Imaging, 2024. Verfasst von Xiaoxi Yu und 14 weiteren Autor:innen. Beteiligte Einrichtung: Department of Vascular Surgery, Chinese Academy of Medical Sciences, Peking Union Medical College Hospital, Beijing, China. Hauptthemen laut MEDLINE: Oxygen Saturation, Peripheral Arterial Disease. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 31 Literaturangaben. Gefördert von: CAMS Innovation Fund for Medical Science, Fundamental Research Funds for the Central Universities, National High Level Hospital Clinical Research Funding.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

A noninvasive and reliable approach to quantitatively measure muscle perfusion of lower extremity is needed to aid the diagnosis and treatment of peripheral artery disease (PAD).

Purpose

To verify the reproductivity of using blood oxygen level‐dependent (BOLD) imaging to evaluate perfusion in lower extremities, and explore its correlation with walking performance in patients with PAD. Study Type Prospective observational study. Subjects Seventeen patients with lower extremity PAD (mean age: 67 ± 6 years, 15 males) and eight older adults (controls). Field Strength/Sequence Dynamic multi‐echo gradient echo T2* weighted imaging at 3T. Assessment Perfusion was analyzed in regions of interest according to muscle groups. Perfusion parameters were measured, such as minimum ischemia value (MIV), time to peak (TTP), and gradient during reactive hyperemia (Grad) by two independent users. Walking performance experiments including short physical performance battery (SPPB) and 6‐minute walk were tested in patients. Statistical Tests BOLD parameters were compared using Mann–Whitney U test and Kruskal–Wallis test. Relations between parameters and walking performance were assessed by Mann–Whitney U test and Spearman's correlation coefficient.

Results

Good to perfect agreement was demonstrated for all perfusion parameters of interuser reproducibility, and the interscan reproducibility of MIV, TTP, and Grad was good. The TTP of the patients was longer than that of the controls (87.85 ± 38.85 s vs. 36.54 ± 7.27 s), while the Grad of patients was smaller (0.16 ± 0.12 msec/s vs. 0.24 ± 0.11 msec/s). Among PAD patients, the MIV was significantly lower in the low SPPB subgroup (score 6–8) than in the high SPPB group (score 9–12), and the TTP was negatively correlated with 6‐minute walk distance ( ρ = −0.549). Data Conclusion BOLD imaging method had overall good reproducibility for the perfusion assessment of calf muscles. The perfusion parameters were different between PAD patients and controls, and were correlated with lower extremity function. Evidence Level 2 Technical Efficacy Stage 2

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Oxygen SaturationPeripheral Arterial DiseaseAgedHumansMaleMiddle AgedIschemiaLower ExtremityMagnetic Resonance ImagingMuscle, SkeletalOxygenReproducibility of ResultsWalkingFemale

Stichwörter der Autor:innen

blood oxygen level-dependentmagnetic resonance imagingperfusion assessmentperipheral artery diseasewalking performance

Substanzen

Oxygen

Autor:innen und Institutionen

  • Department of Vascular Surgery, Chinese Academy of Medical Sciences, Peking Union Medical College Hospital, Beijing, China.
  • Department of Radiology, Chinese Academy of Medical Sciences, Peking Union Medical College Hospital, Beijing, China.
  • MR Collaboration, Siemens Healthineers Ltd., Beijing, China.
  • Advanced Therapies Collaboration, Siemens Healthineers Ltd., Beijing, China.

ORCID-Profile: Xiaoxi Yu, Xiaoyuan Fan, Feng Feng

Förderung

  • CAMS Innovation Fund for Medical Science
  • Fundamental Research Funds for the Central Universities
  • National High Level Hospital Clinical Research Funding
  • National Natural Science Foundation of China
  • Non-profit Central Research Institute Fund of Chinese Academy of Medical Sciences
  • Youth Fund of National Natural Science Foundation of China

Zitieren

APA

Yu, X., Liu, Z., Shao, J., Qu, J., Lai, Z., Yuan, L., Ma, J., Fan, X., Ye, L., Li, K., Zhang, Y., Wang, F., Liu, B., Jin, Z., & Feng, F. (2024). Blood Oxygen Level‐Dependent MR Imaging of Lower Extremities in Peripheral Artery Disease and Its Correlation With Walking Performance. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.28757

Vancouver

Yu X, Liu Z, Shao J, Qu J, Lai Z, Yuan L, et al. Blood Oxygen Level‐Dependent MR Imaging of Lower Extremities in Peripheral Artery Disease and Its Correlation With Walking Performance. Journal of Magnetic Resonance Imaging. 2024. doi:10.1002/jmri.28757

BibTeX
@article{Yu2024,
  author = {Yu, Xiaoxi and Liu, Zhaoxi and Shao, Jiang and Qu, Jianxun and Lai, Zhichao and Yuan, Ling and Ma, Jiangyu and Fan, Xiaoyuan and Ye, Luming and Li, Kang and Zhang, Yan and Wang, Fengdan and Liu, Bao and Jin, Zhengyu and Feng, Feng},
  title = {Blood Oxygen Level‐Dependent MR Imaging of Lower Extremities in Peripheral Artery Disease and Its Correlation With Walking Performance},
  journal = {Journal of Magnetic Resonance Imaging},
  year = {2024},
  doi = {10.1002/jmri.28757}
}
Kostenlos starten →