In Vivo MRI Tracking of Degradable Polyurethane Hydrogel Degradation In Situ Using a Manganese Porphyrin Contrast Agent
Journal of Magnetic Resonance Imaging · 2023
DOI: 10.1002/jmri.28664 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Magnetic Resonance Imaging, 2023. Verfasst von Eric Tawagi und 4 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Biomedical Engineering, University of Toronto, Toronto, Ontario, Canada. Hauptthemen laut MEDLINE: Contrast Media, Porphyrins. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Canada Foundation for Innovation, Natural Sciences and Engineering Research Council of Canada.
Abstract (Originalsprache)
Background
A noninvasive method to track implanted biomaterials is desirable for real‐time monitoring of material interactions with host tissues and assessment of efficacy and safety.
Purpose
To explore quantitative in vivo tracking of polyurethane implants using a manganese porphyrin (MnP) contrast agent containing a covalent binding site for pairing to polymers. Study Type Prospective, longitudinal. Animal Model Rodent model of dorsal subcutaneous implants (10 female Sprague Dawley rats). Field Strength/Sequence A 3‐T; two‐dimensional (2D) T1‐weighted spin‐echo (SE), T2‐weighted turbo SE, three‐dimensional (3D) spoiled gradient‐echo T1 mapping with variable flip angles. Assessment A new MnP‐vinyl contrast agent to covalently label polyurethane hydrogels was synthesized and chemically characterized. Stability of binding was assessed in vitro. MRI was performed in vitro on unlabeled hydrogels and hydrogels labeled at different concentrations, and in vivo on rats with unlabeled and labeled hydrogels implanted dorsally. In vivo MRI was performed at 1, 3, 5, and 7 weeks postimplantation. Implants were easily identified on T1‐weighted SE, and fluid accumulation from inflammation was distinguished on T2‐weighted turbo SE. Implants were segmented on contiguous T1‐weighted SPGR slices using a threshold of 1.8 times the background muscle signal intensity; implant volume and mean T1 values were then calculated at each timepoint. Histopathology was performed on implants in the same plane as MRI and compared to imaging results. Statistical Tests Unpaired t ‐tests and one‐way analysis of variance (ANOVA) were used for comparisons. A P value
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Institute of Biomedical Engineering, University of Toronto, Toronto, Ontario, Canada.
- Translational Biology & Engineering Program, Ted Rogers Centre for Heart Research, Toronto, Ontario, Canada.
- Faculty of Dentistry, University of Toronto, Toronto, Ontario, Canada.
- The Edward S. Rogers Sr. Department of Electrical & Computer Engineering, University of Toronto, Toronto, Ontario, Canada.
ORCID-Profile: Eric Tawagi, Hai-Ling Margaret Cheng
Förderung
- Canada Foundation for Innovation
- Natural Sciences and Engineering Research Council of Canada
Zitieren
APA
Tawagi, E., Vollett, K. D. W., Szulc, D. A., Santerre, J. P., & Cheng, H. M. (2023). In Vivo MRI Tracking of Degradable Polyurethane Hydrogel Degradation In Situ Using a Manganese Porphyrin Contrast Agent. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.28664
Vancouver
Tawagi E, Vollett KDW, Szulc DA, Santerre JP, Cheng HM. In Vivo MRI Tracking of Degradable Polyurethane Hydrogel Degradation In Situ Using a Manganese Porphyrin Contrast Agent. Journal of Magnetic Resonance Imaging. 2023. doi:10.1002/jmri.28664
BibTeX
@article{Tawagi2023,
author = {Tawagi, Eric and Vollett, Kyle D W and Szulc, Daniel A and Santerre, J Paul and Cheng, Hai-Ling Margaret},
title = {In Vivo MRI Tracking of Degradable Polyurethane Hydrogel Degradation In Situ Using a Manganese Porphyrin Contrast Agent},
journal = {Journal of Magnetic Resonance Imaging},
year = {2023},
doi = {10.1002/jmri.28664}
}
EUVIMED