A New OATP ‐Mediated Hepatobiliary‐Specific Mn( II )‐Based MRI Contrast Agent for Hepatocellular Carcinoma in Mice: A Comparison With Gd‐EOB‐DTPA
Journal of Magnetic Resonance Imaging · 2023
DOI: 10.1002/jmri.28590 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Magnetic Resonance Imaging, 2023. Verfasst von Yuan Xue und 7 weiteren Autor:innen. Beteiligte Einrichtung: Medical Imaging Key Laboratory of Sichuan Province, Department of Oncology, Affiliated Hospital of North Sichuan Medical College, Nanchong, Sichuan, …. Hauptthemen laut MEDLINE: Carcinoma, Hepatocellular, Liver Neoplasms, Organic Anion Transporters. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 37 Literaturangaben. Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
Background
Growing concerns about the safety of gadolinium (Gd)‐based contrast agents have reinforced the need for the development of Gd‐free MRI contrast agents (CAs) that are effective in imaging liver tumors.
Purpose
To evaluate the ability of Mn‐BnO‐TyEDTA MRI CA to detect hepatocellular carcinoma in a mouse model of implanted liver tumor. Study Type Prospective. Animal Model Thirteen orthotopically implanted liver tumor mice. Field Strength/Sequence 3.0 T/precontrast and postcontrast T1 ‐weighted fast spoiled gradient recalled echo and T2 ‐weighted fast recovery fast spin‐echo imaging with fat suppression. Assessment The relative enhancement ratio was calculated and statistically compared. Lesion detection in postcontrast images was analyzed by calculations of area under the curve (AUC, the increases in liver‐to‐tumor contrast‐to‐noise ratio [∆CNR] vs. time curve). Mn or Gd levels were measured in the liver and tumoral tissues by inductively coupled plasma‐mass spectrometry. Tumor specimens were stained with hematoxylin and eosin (H&E) and the expression of organic anion transfer peptide (OATP)1B1 was evaluated by immunofluorescence (IF) staining and mean fluorescence intensity (MFI) was calculated. Statistical Tests Unpaired t ‐test and two‐tailed paired t ‐test. P < 0.05 was considered statistical significance.
Results
Mn‐BnO‐TyEDTA and Gd‐EOB‐DTPA demonstrated nearly identical enhancement patterns in the liver, tumor, and psoas muscle and no difference in lesion detection (AUC 10–30, Mn = 851 ∆CR·min, AUC 10–30, Gd = 823 ∆CR·min). A Significant higher concentration of metal (Mn or Gd) was found in the liver compared to the tumor ([Mn] liver = 0.88 ± 0.07 μmmol/g, [Mn] tumor = 0.49 ± 0.05 μmmol/g, [Gd] liver = 0.65 ± 0.07 μmmol/g, [Gd] tumor = 0.27 ± 0.04 μmmol/g). IF staining showed significantly decreased expression of OATP1B1 in the tumor core compared to the liver (MFI tumor = 5.28 ± 1.54, MFI liver = 25.49 ± 3.41). Data Conclusion Mn‐BnO‐TyEDTA can provide comparable hepatobiliary tumor contrast enhancement to Gd‐EOB‐DTPA. Evidence Level 1 Technical Efficacy Stage 1
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Medical Imaging Key Laboratory of Sichuan Province, Department of Oncology, Affiliated Hospital of North Sichuan Medical College, Nanchong, Sichuan, China.
- School of Basic Medical Sciences and Forensic Medicine, North Sichuan Medical College, Nanchong, Sichuan, China.
- Wenzhou Key Laboratory of Biophysics, Wenzhou Institute, University of Chinese Academy of Sciences, Wenzhou, Zhejiang, China.
- School of Pharmacy, North Sichuan Medical College, Nanchong, Sichuan, China.
ORCID-Profile: Jiang Zhu
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Xue, Y., Xiao, B., Xia, Z., Dai, L., Xia, Q., Zhong, L., Zhu, C., & Zhu, J. (2023). A New OATP ‐Mediated Hepatobiliary‐Specific Mn( II )‐Based MRI Contrast Agent for Hepatocellular Carcinoma in Mice: A Comparison With Gd‐EOB‐DTPA. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.28590
Vancouver
Xue Y, Xiao B, Xia Z, Dai L, Xia Q, Zhong L, et al. A New OATP ‐Mediated Hepatobiliary‐Specific Mn( II )‐Based MRI Contrast Agent for Hepatocellular Carcinoma in Mice: A Comparison With Gd‐EOB‐DTPA. Journal of Magnetic Resonance Imaging. 2023. doi:10.1002/jmri.28590
BibTeX
@article{Xue2023,
author = {Xue, Yuan and Xiao, Bin and Xia, Zhiyang and Dai, Lixiong and Xia, Qian and Zhong, Lei and Zhu, Chunrong and Zhu, Jiang},
title = {A New OATP ‐Mediated Hepatobiliary‐Specific Mn( II )‐Based MRI Contrast Agent for Hepatocellular Carcinoma in Mice: A Comparison With Gd‐EOB‐DTPA},
journal = {Journal of Magnetic Resonance Imaging},
year = {2023},
doi = {10.1002/jmri.28590}
}
EUVIMED