Fully Automated Radiosynthesis of No‐Carrier‐Added [ 11 C]Butanol Using the GE FASTLab 2 Module
Journal of Labelled Compounds and Radiopharmaceuticals · 2025
DOI: 10.1002/jlcr.4158 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Labelled Compounds and Radiopharmaceuticals, 2025. Verfasst von Ivan E Wang und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medicinal Chemistry, College of Pharmacy, University of Michigan, Ann Arbor, Michigan, USA. Hauptthemen laut MEDLINE: Carbon Radioisotopes, Butanols, Radiochemistry. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of Michigan.
Abstract (Originalsprache)
Radiolabeled alcohols have been investigated for their use in the measurement of cerebral blood flow for years. In particular, [ 11 C]butanol has been employed as a freely diffusible tracer with appreciable tissue retention and good solubility in both lipid and aqueous compartments. It is an appropriate radiotracer for the assessment of blood supply and for the comparative evaluation of substrate utilization with blood flow. Herein, we describe a no‐carrier‐added [ 11 C]butanol radiosynthesis using the GE FASTLab 2 to leverage the benefits of a cassette‐based workflow, and we compare it to our legacy radiosynthesis using GE TracerLab FX modules. Using the FASTLab 2, [ 11 C]butanol was synthesized in 21 min with a radiochemical yield of 4%–8% ( n = 3) and a radiochemical purity of > 90%. Synthesis on the FASTLab was fast, reliable, and comparable to syntheses using TracerLab FX modules.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Medicinal Chemistry, College of Pharmacy, University of Michigan, Ann Arbor, Michigan, USA.
- Department of Radiology, University of Michigan, Ann Arbor, Michigan, USA.
- Department of Pharmacology, University of Michigan, Ann Arbor, Michigan, USA.
ORCID-Profile: Ivan E Wang, Jason A Witek, Marianna Dakanali, Peter J H Scott
Förderung
- University of Michigan
Zitieren
APA
Wang, I. E., Witek, J. A., Pakula, R. J., Henderson, B. D., Dakanali, M., Shao, X., & Scott, P. J. H. (2025). Fully Automated Radiosynthesis of No‐Carrier‐Added [ 11 C]Butanol Using the GE FASTLab 2 Module. Journal of Labelled Compounds and Radiopharmaceuticals. https://doi.org/10.1002/jlcr.4158
Vancouver
Wang IE, Witek JA, Pakula RJ, Henderson BD, Dakanali M, Shao X, et al. Fully Automated Radiosynthesis of No‐Carrier‐Added [ 11 C]Butanol Using the GE FASTLab 2 Module. Journal of Labelled Compounds and Radiopharmaceuticals. 2025. doi:10.1002/jlcr.4158
BibTeX
@article{Wang2025,
author = {Wang, Ivan E and Witek, Jason A and Pakula, Ryan J and Henderson, Bradford D and Dakanali, Marianna and Shao, Xia and Scott, Peter J H},
title = {Fully Automated Radiosynthesis of No‐Carrier‐Added [ 11 C]Butanol Using the GE FASTLab 2 Module},
journal = {Journal of Labelled Compounds and Radiopharmaceuticals},
year = {2025},
doi = {10.1002/jlcr.4158}
}
EUVIMED