EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Automated radiosynthesis of [ 18 F]CETO, a PET radiotracer for imaging adrenal glands, on Synthra RNplus

Matthew Hird iD, Joseph J Russell, Lei Li Corrigan, Istvan Boros, Patrik Nordeman iD, Gunnar Antoni, Mark Gurnell, Franklin I Aigbirhio

Journal of Labelled Compounds and Radiopharmaceuticals · 2024

DOI: 10.1002/jlcr.4078 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Labelled Compounds and Radiopharmaceuticals, 2024. Verfasst von Matthew Hird und 7 weiteren Autor:innen. Beteiligte Einrichtung: Molecular Imaging Chemistry Laboratory, Wolfson Brain Imaging Centre, Department of Clinical Neuroscience, University of Cambridge, Cambridge, UK. Hauptthemen laut MEDLINE: Radiopharmaceuticals, Fluorine Radioisotopes. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 15 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Medical Research Council, National Institute for Health and Care Research.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Primary aldosteronism (PA) is the leading secondary cause of hypertension. Determining whether one (unilateral) or both (bilateral) adrenal glands are the source of PA in a patient remains challenging, and yet it is a critical step in the decision whether to recommend potentially curative surgery (adrenalectomy) or lifelong medical therapy (typically requiring multiple drugs). Recently, we have developed a fluorine‐18 radiopharmaceutical [ 18 F]CETO to permit greater access to PA molecular imaging. Herein, we report an automated synthesis of this radiotracer. To manufacture the radiopharmaceutical routinely for clinical PET studies, we implemented an automated radiosynthesis method on a Synthra RNplus© synthesiser for which Cl‐tosyletomidate was used as the precursor for radiolabelling via nucleophilic [ 18 F]fluorination. [ 18 F]CETO was produced with 35 ± 1% ( n = 7), decay corrected and 25 ± 4% ( n = 7) non‐decay corrected radiochemical yield with molar activities ranging from 150 to 400 GBq/μmol. The GMP compliant manufacturing process produces a sterile formulated [ 18 F]CETO injectable solution for human use as demonstrated by the results of quality control. Automation of the radiosynthesis of [ 18 F]CETO should facilitate uptake by other adrenal centres and increase access to molecular imaging in PA.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RadiopharmaceuticalsFluorine RadioisotopesHumansMolecular ImagingAdrenal GlandsRadiochemistryPositron-Emission Tomography

Stichwörter der Autor:innen

PET imagingSynthra RNplus[18F]CETOadrenalfluorine-18 radiosynthesisprimary aldosteronism

Substanzen

RadiopharmaceuticalsFluorine Radioisotopes

Autor:innen und Institutionen

  • Molecular Imaging Chemistry Laboratory, Wolfson Brain Imaging Centre, Department of Clinical Neuroscience, University of Cambridge, Cambridge, UK.
  • Radiopharmaceutical Unit, Wolfson Brain Imaging Centre, Department of Clinical Neurosciences, School of Clinical Medicine, University of Cambridge, Cambridge, UK.
  • Uppsala Biomedicinska Centrum, BMC, Uppsala, Sweden.
  • Welcome-MRC Institute of Metabolic Science and Department of Medicine, University of Cambridge, Cambridge Biomedical Campus, Cambridge, UK.
  • Addenbrooke's Hospital, Cambridge Biomedical Campus, Cambridge, UK.

ORCID-Profile: Matthew Hird, Patrik Nordeman

Förderung

  • Medical Research Council
  • National Institute for Health and Care Research

Zitieren

APA

Hird, M., Russell, J. J., Corrigan, L. L., Boros, I., Nordeman, P., Antoni, G., Gurnell, M., & Aigbirhio, F. I. (2024). Automated radiosynthesis of [ 18 F]CETO, a PET radiotracer for imaging adrenal glands, on Synthra RNplus. Journal of Labelled Compounds and Radiopharmaceuticals. https://doi.org/10.1002/jlcr.4078

Vancouver

Hird M, Russell JJ, Corrigan LL, Boros I, Nordeman P, Antoni G, et al. Automated radiosynthesis of [ 18 F]CETO, a PET radiotracer for imaging adrenal glands, on Synthra RNplus. Journal of Labelled Compounds and Radiopharmaceuticals. 2024. doi:10.1002/jlcr.4078

BibTeX
@article{Hird2024,
  author = {Hird, Matthew and Russell, Joseph J and Corrigan, Lei Li and Boros, Istvan and Nordeman, Patrik and Antoni, Gunnar and Gurnell, Mark and Aigbirhio, Franklin I},
  title = {Automated radiosynthesis of [ 18 F]CETO, a PET radiotracer for imaging adrenal glands, on Synthra RNplus},
  journal = {Journal of Labelled Compounds and Radiopharmaceuticals},
  year = {2024},
  doi = {10.1002/jlcr.4078}
}
Kostenlos starten →