Low sensitivity of the fourth‐generation antigen/antibody HIV rapid diagnostic test Determine™ HIV Early Detect for detection of acute HIV infection at the point of care in rural Eswatini: a diagnostic accuracy study
Journal of the International AIDS Society · 2025
DOI: 10.1002/jia2.26517 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of the International AIDS Society, 2025. Verfasst von Iza Ciglenecki und 15 weiteren Autor:innen. Beteiligte Einrichtung: Médecins Sans Frontières (MSF), Geneva, Switzerland. Hauptthemen laut MEDLINE: HIV Infections, HIV Antibodies, Diagnostic Tests, Routine, Point-of-Care Systems. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Médecins Sans Frontières, Operational center Geneva.
Abstract (Originalsprache)
Introduction
The diagnosis of acute HIV infection (AHI) is challenging in routine settings because it cannot be detected by routine third‐generation antibody rapid diagnostic tests (RDTs). The current fourth‐generation antibody/antigen RDT, Determine™ HIV Early Detect, has demonstrated high sensitivity in laboratory studies, but field evaluations at the point of care are lacking. We nested a diagnostic accuracy study within a larger study of the burden of sexually transmitted infections in rural Eswatini.
Methods
Adults were enrolled at six routine HIV testing sites (HTS) in the Shiselweni region between June 2022 and April 2023. Determine™ HIV Early Detect was performed by HTS counsellors in parallel with routine HIV testing using a finger‐prick blood sample. The reference test was HIV viral load (VL) in the plasma sample, performed on the Xpert platform in the central laboratory. AHI was defined as a negative or discordant HIV test result according to the national serial RDT algorithm and an HIV VL >10,000 copies/ml, or two consecutive HIV VL measurements between the lower limit of detection (40 copies/ml) and 10,000 copies/ml. Established HIV infection was defined as a positive serial RDT test, and overall HIV infection as either established HIV infection or AHI.
Results
One thousand one hundred and sixty‐three participants had all test results available; 49 (4.2%) were diagnosed with HIV (39 with established HIV according to the serial RDT algorithm and 10 with AHI). AHI prevalence among participants with HIV negative or discordant routine RDT results was 0.9% (10/1124). The sensitivity of Determine™ HIV Early Detect to detect overall HIV infection was 83.7% (95% CI 70.3–92.7) and to detect AHI was 20% (95% CI 2.5–55.6%); the specificity was equally high for both 99.8% (95% CI 99.4–100).
Conclusions
The low sensitivity of Determine™ HIV Early Detect to detect AHI when performed at the point of care using finger‐prick blood samples in our study contrasts with other published evaluations from laboratory settings and highlights the importance of field evaluations of the commonly used diagnostic tests.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Médecins Sans Frontières (MSF), Geneva, Switzerland.
- Institute of Global Health, University of Geneva, Geneva, Switzerland.
- Médecins Sans Frontières (MSF), Mbabane, Eswatini.
- Eswatini National AIDS Programme (ENAP), Ministry of Health, Mbabane, Eswatini.
- National Reference Laboratory (NRL), Ministry of Health, Mbabane, Eswatini.
- Southern Africa Medical Unit (SAMU), Médecins Sans Frontières, Cape Town, South Africa.
ORCID-Profile: Iza Ciglenecki, Esther Mukooza, Alexandra Calmy, Bernhard Kerschberger
Förderung
- Médecins Sans Frontières, Operational center Geneva
Zitieren
APA
Ciglenecki, I., Ntshalintshali, N., Mukooza, E., Lekelem, S., Mavimbela, M., Dlamini, S., Dube, L., Mabuza, N., Haile, M., Ellman, T., Flores, A., Keiser, O., Matse, S., de la Tour, R., Calmy, A., & Kerschberger, B. (2025). Low sensitivity of the fourth‐generation antigen/antibody HIV rapid diagnostic test Determine™ HIV Early Detect for detection of acute HIV infection at the point of care in rural Eswatini: a diagnostic accuracy study. Journal of the International AIDS Society. https://doi.org/10.1002/jia2.26517
Vancouver
Ciglenecki I, Ntshalintshali N, Mukooza E, Lekelem S, Mavimbela M, Dlamini S, et al. Low sensitivity of the fourth‐generation antigen/antibody HIV rapid diagnostic test Determine™ HIV Early Detect for detection of acute HIV infection at the point of care in rural Eswatini: a diagnostic accuracy study. Journal of the International AIDS Society. 2025. doi:10.1002/jia2.26517
BibTeX
@article{Ciglenecki2025,
author = {Ciglenecki, Iza and Ntshalintshali, Nombuso and Mukooza, Esther and Lekelem, Skinner and Mavimbela, Mpumelelo and Dlamini, Sindisiwe and Dube, Lenhle and Mabuza, Nomvuyo and Haile, Melat and Ellman, Tom and Flores, Antonio and Keiser, Olivia and Matse, Sindy and de la Tour, Roberto and Calmy, Alexandra and Kerschberger, Bernhard},
title = {Low sensitivity of the fourth‐generation antigen/antibody HIV rapid diagnostic test Determine™ HIV Early Detect for detection of acute HIV infection at the point of care in rural Eswatini: a diagnostic accuracy study},
journal = {Journal of the International AIDS Society},
year = {2025},
doi = {10.1002/jia2.26517}
}
EUVIMED