EUVIMEDEUVIMED entdecken
Crossref

A prospective study on the histological evaluation of type 1 autoimmune pancreatitis using endoscopic ultrasound‐guided fine needle biopsy with a 19‐gauge Franseen needle

Takuya Ishikawa iD, Kentaro Yamao iD, Yasuyuki Mizutani, Tadashi Iida, Kota Uetsuki, Yoshie Shimoyama, Masanao Nakamura, Kazuhiro Furukawa, Takeshi Yamamura, Hiroki Kawashima iD

Journal of Hepato-Biliary-Pancreatic Sciences · 2024

DOI: 10.1002/jhbp.1438 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Hepato-Biliary-Pancreatic Sciences, 2024. Verfasst von Takuya Ishikawa und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Gastroenterology and Hepatology, Nagoya University Graduate School of Medicine, Nagoya, Japan. Hauptthemen laut MEDLINE: Autoimmune Pancreatitis, Endoscopic Ultrasound-Guided Fine Needle Aspiration, Needles. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 22 Literaturangaben. Gefördert von: JSPS KAKENHI Grant Number, JST (Moonshot R&D).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background/Purpose To assess the diagnostic efficacy and safety of endoscopic ultrasound‐guided fine needle biopsy (EUS‐FNB) using a 19‐gauge Franseen needle for autoimmune pancreatitis (AIP).

Methods

Twenty patients suspected of having type 1 AIP were prospectively enrolled and underwent EUS‐FNB with a 19‐gauge Franseen needle. Their data were compared with those of historical controls: a total of 29 type 1 AIP patients had EUS‐FNB with a 22‐gauge Franseen needle.

Results

Specimens suitable for histological evaluation were obtained from 19 of the 20 patients (95%), and the median total tissue area was 11.9 mm 2 . The histological diagnosis rate of AIP was 65% (95% CI: 43.2%–82%). Adverse events were observed in three patients (15%), and a switch to 22‐gauge needles occurred during transduodenal puncture in two patients. Compared to those punctured with 22‐gauge needles, patients punctured with 19‐gauge needles had greater prevalence of each characteristic feature of lymphoplasmacytic sclerosing pancreatitis, but the difference was not statistically significant.

Conclusions

EUS‐FNB using a 19‐gauge Franseen needle demonstrated favorable performance for the histological diagnosis of AIP and allowed for large tissue samples, potentially facilitating pathological diagnosis. However, during transduodenal puncture, maneuverability is reduced; therefore, the needle may need to be selected according to the puncture site.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Autoimmune PancreatitisEndoscopic Ultrasound-Guided Fine Needle AspirationNeedlesHumansProspective StudiesMaleFemaleMiddle AgedAgedAdultEquipment Design

Stichwörter der Autor:innen

19‐gauge22‐gaugeFranseen needleendoscopic ultrasound‐guided fine‐needle biopsytype 1 autoimmune pancreatitis

Autor:innen und Institutionen

  • Department of Gastroenterology and Hepatology, Nagoya University Graduate School of Medicine, Nagoya, Japan.
  • Department of Pathology and Laboratory Medicine, Nagoya University Graduate School of Medicine, Nagoya, Japan.
  • Department of Endoscopy, Nagoya University Hospital, Nagoya, Japan.

ORCID-Profile: Takuya Ishikawa, Kentaro Yamao, Hiroki Kawashima

Förderung

  • JSPS KAKENHI Grant Number
  • JST (Moonshot R&D)

Zitieren

APA

Ishikawa, T., Yamao, K., Mizutani, Y., Iida, T., Uetsuki, K., Shimoyama, Y., Nakamura, M., Furukawa, K., Yamamura, T., & Kawashima, H. (2024). A prospective study on the histological evaluation of type 1 autoimmune pancreatitis using endoscopic ultrasound‐guided fine needle biopsy with a 19‐gauge Franseen needle. Journal of Hepato-Biliary-Pancreatic Sciences. https://doi.org/10.1002/jhbp.1438

Vancouver

Ishikawa T, Yamao K, Mizutani Y, Iida T, Uetsuki K, Shimoyama Y, et al. A prospective study on the histological evaluation of type 1 autoimmune pancreatitis using endoscopic ultrasound‐guided fine needle biopsy with a 19‐gauge Franseen needle. Journal of Hepato-Biliary-Pancreatic Sciences. 2024. doi:10.1002/jhbp.1438

BibTeX
@article{Ishikawa2024,
  author = {Ishikawa, Takuya and Yamao, Kentaro and Mizutani, Yasuyuki and Iida, Tadashi and Uetsuki, Kota and Shimoyama, Yoshie and Nakamura, Masanao and Furukawa, Kazuhiro and Yamamura, Takeshi and Kawashima, Hiroki},
  title = {A prospective study on the histological evaluation of type 1 autoimmune pancreatitis using endoscopic ultrasound‐guided fine needle biopsy with a 19‐gauge Franseen needle},
  journal = {Journal of Hepato-Biliary-Pancreatic Sciences},
  year = {2024},
  doi = {10.1002/jhbp.1438}
}
Kostenlos starten →