Size photometry and fluorescence imaging of immobilized immersed extracellular vesicles
Journal of Extracellular Vesicles · 2024-10 · 13 (10)
DOI: 10.1002/jev2.12512 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Extracellular Vesicles, online erschienen am 14.10.2024. Verfasst von Andreas Wallucks und 4 weiteren Autor:innen. Beteiligte Einrichtung: Biomedical Engineering Department, McGill University, Montreal, QC, Canada. Hauptthemen laut MEDLINE: Extracellular Vesicles. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Schmidt Science Fellows, Natural Sciences and Engineering Research Council of Canada, Genome Canada Disruptive Innovation in Genomics.
Abstract (Originalsprache)
Immunofluorescence analysis of individual extracellular vesicles (EVs) in common fluorescence microscopes is gaining popularity due to its accessibility and high fluorescence sensitivity; however, EV number and size are only measurable using fluorescent stains requiring extensive sample manipulations. Here we introduce highly sensitive label‐free EV size photometry (SP) based on interferometric scattering (iSCAT) imaging of immersed EVs immobilized on a glass coverslip. We implement SP on a common inverted epifluorescence microscope with LED illumination and a simple 50:50 beamsplitter, permitting seamless integration of SP with fluorescence imaging (SPFI). We present a high‐throughput SPFI workflow recording >10,000 EVs in 7 min over ten 88 × 88 µm 2 fields of view, pre‐ and post‐incubation imaging to suppress background, along with automated image alignment, aberration correction, spot detection and EV sizing. We achieve an EV sizing range from 37 to ∼220 nm in diameter with a dual 440 and 740 nm SP illumination scheme, and suggest that this range can be extended by more advanced image analysis or additional hardware customization. We benchmark SP to flow cytometry using calibrated silica nanoparticles and demonstrate superior, label‐free sensitivity. We showcase SPFI's potential for EV analysis by experimentally distinguishing surface and volumetric EV dyes, observing the deformation of EVs adsorbed to a surface, and by uncovering distinct subpopulations in
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Biomedical Engineering Department, McGill University, Montreal, QC, Canada.
- Victor Phillip Dahdaleh Institute of Genomic Medicine, McGill University, Montreal, QC, Canada.
ORCID-Profile: Andreas Wallucks, Philippe DeCorwin-Martin, Molly L Shen, Andy Ng, David Juncker
Förderung
- Schmidt Science Fellows
- Natural Sciences and Engineering Research Council of Canada
- Genome Canada Disruptive Innovation in Genomics
- Cancer Research Society
- Canada Research Chairs
Zitieren
APA
Wallucks, A., DeCorwin-Martin, P., Shen, M. L., Ng, A., & Juncker, D. (2024). Size photometry and fluorescence imaging of immobilized immersed extracellular vesicles. Journal of Extracellular Vesicles, 13(10). https://doi.org/10.1002/jev2.12512
Vancouver
Wallucks A, DeCorwin-Martin P, Shen ML, Ng A, Juncker D. Size photometry and fluorescence imaging of immobilized immersed extracellular vesicles. Journal of Extracellular Vesicles. 2024;13(10). doi:10.1002/jev2.12512
BibTeX
@article{Wallucks2024,
author = {Wallucks, Andreas and DeCorwin-Martin, Philippe and Shen, Molly L and Ng, Andy and Juncker, David},
title = {Size photometry and fluorescence imaging of immobilized immersed extracellular vesicles},
journal = {Journal of Extracellular Vesicles},
year = {2024},
volume = {13},
number = {10},
doi = {10.1002/jev2.12512}
}
EUVIMED