Fachartikel in der Zeitschrift Journal of Experimental Orthopaedics, online erschienen am 19.03.2026. Verfasst von Mukesh Laddha und 3 weiteren Autor:innen. Beteiligte Einrichtung: RNH Hospital Nagpur India. Die Arbeit nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purpose
Tibial spine avulsion fractures compromise ACL function and are common in children and adolescents. Traditional fixation methods may risk physeal injury and intra‐articular damage. Arthroscopic suture‐based techniques offer a minimally invasive, physeal‐sparing alternative.
Methods
Twenty‐five patients (mean age: 19 years) with type II–IV tibial spine fractures underwent arthroscopic anterior row suture fixation using knotless anchors. Functional outcomes as Lysholm, Internation Knee Documentation Committee rating score (IKDC), Range of motion (ROM), stability, and radiological healing were assessed over 24 months.
Results
All patients achieved radiographic union (mean: 16 weeks). Final follow‐up showed restoration of pre‐injury Lysholm (94 ± 5 to 93.6 ± 0.8), IKDC (84 ± 7 to 83.9 ± 0.7), and ROM (142°–140°). No instability, growth disturbance, or hardware‐related complications were observed.
Conclusion
This technique provides stable fixation, preserves the physis, and avoids intra‐articular hardware. Functional and radiological outcomes were excellent, supporting arthroscopic suture fixation as a safe and effective option for tibial spine avulsion fractures. Level of Evidence Level III, prospective study.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- RNH Hospital Nagpur India.
- JMCH Jodhpur Rajasthan India.
- Department of Clinical and Molecular Sciences Clinical Orthopaedics Ancona Italy.
- IRCCS INRCA Ancona Italy.
- KNEECARES - the superspeciality knee clinic Jaipur India.
- Division of Orthopaedic Surgery Queen's University Kingston Ontario Canada.
ORCID-Profile: Luca Farinelli
Zitieren
APA
Laddha, M., Bhardwaj, L., Farinelli, L., & Meena, A. (2026). Good functional outcomes and radiological union following arthroscopic knotless anchor fixation of tibial spine avulsion fractures: A prospective clinical study. Journal of Experimental Orthopaedics, 13(1). https://doi.org/10.1002/jeo2.70692
Vancouver
Laddha M, Bhardwaj L, Farinelli L, Meena A. Good functional outcomes and radiological union following arthroscopic knotless anchor fixation of tibial spine avulsion fractures: A prospective clinical study. Journal of Experimental Orthopaedics. 2026;13(1). doi:10.1002/jeo2.70692
BibTeX
@article{Laddha2026,
author = {Laddha, Mukesh and Bhardwaj, Lakshya and Farinelli, Luca and Meena, Amit},
title = {Good functional outcomes and radiological union following arthroscopic knotless anchor fixation of tibial spine avulsion fractures: A prospective clinical study},
journal = {Journal of Experimental Orthopaedics},
year = {2026},
volume = {13},
number = {1},
doi = {10.1002/jeo2.70692}
}
EUVIMED