Validation of a high‐fidelity simulator for diagnostic knee arthroscopy training
Journal of Experimental Orthopaedics · 2026-01 · 13 (1)
DOI: 10.1002/jeo2.70684 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Experimental Orthopaedics, online erschienen am 18.03.2026. Verfasst von Oliver Tze Rong Lim und 8 weiteren Autor:innen. Beteiligte Einrichtung: Yong Loo Lin School of Medicine National University of Singapore Singapore. Die Arbeit nennt 15 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purpose
To validate a high‐fidelity arthroscopic simulator by assessing its construct, face and content validity for diagnostic knee arthroscopy training.
Methods
Eighty‐one participants (novices = 41, intermediates = 20 and experts = 20) performed a knee arthroscopy navigation task requiring identification of nine intra‐articular landmarks, repeated for up to five trials with a 10‐min limit per trial. Task‐completion times and attrition were recorded. Performance was analysed using Kruskal–Wallis and Mann–Whitney tests with effect sizes. Post‐task questionnaires evaluated face validity, content validity, educational value and user‐friendliness.
Results
Performance times differed significantly between experience groups ( p < 0.001–0.043). Experts completed Trial 1 in roughly one third the time required by novices (90 s vs. 292 s; r = 0.78). All groups improved with repetition, with steep early gains in novices and the most consistent improvement among intermediates. Between‐group differences narrowed in later trials, although interpretation is limited by attrition and survivorship bias, with only six novices completing Trial 5. Face validity ratings were high (mean > 7/10), and content validity was strongly endorsed (92%–97% supporting curricular integration). Educational value was rated positively (92.3–97.4%), whereas user‐friendliness received lower agreement (35.9%).
Conclusions
This high‐fidelity simulator demonstrated strong construct, face and content validity, reliably discriminating between experience levels and supporting early‐phase skills acquisition. Strong realism and educational value ratings support its potential role in structured arthroscopic training, although usability findings highlight opportunities for ergonomic and instructional refinement. Future research should assess transfer validity and operative performance impact. Level of Evidence Level III, prospective observational validation study.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Yong Loo Lin School of Medicine National University of Singapore Singapore.
- Department of Orthopaedic Surgery Singapore General Hospital Singapore.
- Department of Orthopaedic Surgery National University Hospital Singapore.
ORCID-Profile: Oliver Tze Rong Lim, Jeremy Tze En Lim, Jingyan Fang, Dileepa Banagala, Samundeeswari Saseendar, Salim A L Habsi, Yee Han Dave Lee, Ying Ren Mok
Zitieren
APA
Lim, O. T. R., Lim, J. T. E., Fang, J., Banagala, D., Saseendar, S., Habsi, S. A. L., Hui, J., Lee, Y. H. D., & Mok, Y. R. (2026). Validation of a high‐fidelity simulator for diagnostic knee arthroscopy training. Journal of Experimental Orthopaedics, 13(1). https://doi.org/10.1002/jeo2.70684
Vancouver
Lim OTR, Lim JTE, Fang J, Banagala D, Saseendar S, Habsi SAL, et al. Validation of a high‐fidelity simulator for diagnostic knee arthroscopy training. Journal of Experimental Orthopaedics. 2026;13(1). doi:10.1002/jeo2.70684
BibTeX
@article{Lim2026,
author = {Lim, Oliver Tze Rong and Lim, Jeremy Tze En and Fang, Jingyan and Banagala, Dileepa and Saseendar, Samundeeswari and Habsi, Salim A L and Hui, James and Lee, Yee Han Dave and Mok, Ying Ren},
title = {Validation of a high‐fidelity simulator for diagnostic knee arthroscopy training},
journal = {Journal of Experimental Orthopaedics},
year = {2026},
volume = {13},
number = {1},
doi = {10.1002/jeo2.70684}
}
EUVIMED